Both views use the same certified data. This device remembers your choice.
DIYCOOL vs First Co. heat pumps
Measured against models of the same size and duct type, DIYCOOL scores higher on 6 of the 6 ratings. DIYCOOL has 75 outdoor models, First Co. has 16 outdoor models. DIYCOOL and First Co. have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- DIYCOOL
- First Co.
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | DIYCOOL | First Co. |
|---|---|---|
| Efficiency index | 54% (higher)median — | 7% (higher)median — |
| COP at 5°F | 43% (higher)median 1.90 | 16% (higher)median 1.60 |
| Capacity retention at 5°F | 62% (higher)median 78% | 10% (higher)median 46% |
| HSPF2 | 62% (higher)median 9.4 | 2% (higher)median 6.3 |
| SEER2 | 59% (higher)median 18.9 | 1% (higher)median 11.9 |
| EER2 | 43% (higher)median 11.0 | 10% (higher)median 10.0 |
| Heating capacity at 5°F | 63% (higher)median 22,530 Btu/h | 9% (higher)median 8,000 Btu/h |
| Outdoor models | 75 | 16 |
| AHRI certifications | 170 | 34 |
Share of models meeting each standard
| Standard | DIYCOOL | First Co. |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 65.3%49 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 60%45 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 1.3%1 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 54.7%41 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 1.3%1 models | 0%0 models |
| ENERGY STAR Cold Climate | 45.3%34 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- DIYCOOL
- First Co.
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | DIYCOOL | First Co. |
|---|---|---|
| Ducted, up to 1.5 tons | 9 · index 57% | 8 · index 6% |
| Ducted, 2 tons | 8 · index 58% | 8 · index 8% |
| Ducted, 2.5 to 3 tons | 14 · index 52% | None |
| Ducted, 3.5 to 4.5 tons | 16 · index 56% | None |
| Non-ducted, up to 1.5 tons | 21 · index 56% | None |
| Non-ducted, 2 tons | 6 · index 52% | None |
| Non-ducted, 2.5 to 3 tons | 15 · index 52% | None |
| Non-ducted, 3.5 to 4.5 tons | 8 · index 47% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | DIYCOOLCold-climate score, best model | First Co.Cold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM8 of 9 models qualify · AHRI 213433267 | None on this board (0 of 8 models qualify) |
| Ducted, 2 tons | 79.6(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB7 of 7 models qualify · AHRI 207825560 | None on this board (0 of 8 models qualify) |
| Ducted, 2.5 to 3 tons | 80.0(50 is the typical model of its size class)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB10 of 15 models qualify · AHRI 210857341 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 86.5(50 is the typical model of its size class)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB12 of 16 models qualify · AHRI 210857342 | No models in this size class |
| Non-ducted, up to 1.5 tons | 89.8(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC11 of 21 models qualify · AHRI 210857334 | No models in this size class |
| Non-ducted, 2 tons | 86.3(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB3 of 6 models qualify · AHRI 207825563 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 80.2(50 is the typical model of its size class)ACIQ-36Z-HH-M4B7 of 15 models qualify · AHRI 207825594 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 76.8(50 is the typical model of its size class)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB5 of 8 models qualify · AHRI 210857346 | No models in this size class |
All-around best
| Size and duct type | DIYCOOLAll-around score, best model | First Co.All-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB9 of 9 models have all five ratings · AHRI 207825557 | 11.9(50 is the typical model of its size class)EHE18***B7 of 8 models have all five ratings · AHRI 213369561 |
| Ducted, 2 tons | 80.2(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB8 of 8 models have all five ratings · AHRI 207825560 | 18.0(50 is the typical model of its size class)EHE24***B6 of 8 models have all five ratings · AHRI 213369562 |
| Ducted, 2.5 to 3 tons | 75.4(50 is the typical model of its size class)ES-27Z-M3B14 of 14 models have all five ratings · AHRI 210857405 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 82.1(50 is the typical model of its size class)ACIQ-48Z-HH-M5B15 of 15 models have all five ratings · AHRI 207825598 | No models in this size class |
| Ducted, 5 tons and up | 42.0(50 is the typical model of its size class)ACIQ-60-EHPBwith ducted air handler ACIQ-60AHB1 of 1 models have all five ratings · AHRI 213433261 | No models in this size class |
| Non-ducted, up to 1.5 tons | 92.3(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC21 of 21 models have all five ratings · AHRI 210857334 | No models in this size class |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB6 of 6 models have all five ratings · AHRI 207825553 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 83.4(50 is the typical model of its size class)ACIQ-36Z-HH-M4B13 of 15 models have all five ratings · AHRI 207825594 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 78.0(50 is the typical model of its size class)ACIQ-48Z-HH-M5B8 of 8 models have all five ratings · AHRI 207825597 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | DIYCOOL | First Co. |
|---|---|---|
| COP at 5°F | beats 92% · 2.21ACIQ-24ZPL-HP230BNon-ducted, 2 tons | beats 65% · 2.08EHE30***BDucted, 2 tons |
| Capacity retention at 5°F | beats 99% · 144%SC-09ZPL-HP230Non-ducted, up to 1.5 tons | beats 21% · 55%EHE30***BDucted, 2 tons |
| HSPF2 | beats 99% · 10.3ACIQ-48ZPL-HP230BDucted, 3.5 to 4.5 tons | beats 14% · 7.224WHHPDucted, 2 tons |
| SEER2 | beats 99% · 20.9ACIQ-48Z-HH-M5BDucted, 3.5 to 4.5 tons | beats 11% · 13.519WHHPDucted, 2 tons |
| EER2 | beats 99% · 16.6SC-09ZPL-HP230Non-ducted, up to 1.5 tons | beats 78% · 12.419WHHPDucted, 2 tons |
| Heating capacity at 5°F | beats 99% · 56,500 Btu/hACIQ-60ZPL-HP230BNon-ducted, 3.5 to 4.5 tons | beats 30% · 14,000 Btu/hEHE30***BDucted, 2 tons |