Skip to content

DIYCOOL vs TRUENORTH heat pumps

Measured against models of the same size and duct type, DIYCOOL scores higher on 6 of the 6 ratings. DIYCOOL has 75 outdoor models, TRUENORTH has 19 outdoor models. DIYCOOL and TRUENORTH have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
DIYCOOL and TRUENORTH on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, DIYCOOL scores higher on 6 of the 6 ratings.
  • DIYCOOL
  • TRUENORTH
  • Other ranked manufacturers
DIYCOOLTRUENORTH

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDIYCOOLTRUENORTH
Efficiency index54% (higher)median —42% (higher)median —
COP at 5°F43% (higher)median 1.9037% (higher)median 1.80
Capacity retention at 5°F62% (higher)median 78%59% (higher)median 72%
HSPF262% (higher)median 9.447% (higher)median 8.5
SEER259% (higher)median 18.939% (higher)median 17.5
EER243% (higher)median 11.033% (higher)median 10.5
Heating capacity at 5°F63% (higher)median 22,530 Btu/h61% (higher)median 20,000 Btu/h
Outdoor models7519
AHRI certifications17071

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDIYCOOLTRUENORTH
CEE 2025 Tier 1 (Split ASHP)65.3%49 models57.9%11 models
CEE 2026 Tier 1 (Split ASHP)60%45 models52.6%10 models
CEE Advanced Tier (Split ASHP)1.3%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)54.7%41 models68.4%13 models
DOE Cold Climate Heat Pump Challenge1.3%1 models0%0 models
ENERGY STAR Cold Climate45.3%34 models57.9%11 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • DIYCOOL
  • TRUENORTH
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDIYCOOLTRUENORTH
Ducted, up to 1.5 tons9 · index 57%3 · index 29%
Ducted, 2 tons8 · index 58%3 · index 40%
Ducted, 2.5 to 3 tons14 · index 52%5 · index 45%
Ducted, 3.5 to 4.5 tons16 · index 56%3 · index 35%
Non-ducted, up to 1.5 tons21 · index 56%6 · index 34%
Non-ducted, 2 tons6 · index 52%2 · index 49%
Non-ducted, 2.5 to 3 tons15 · index 52%3 · index 69%
Non-ducted, 3.5 to 4.5 tons8 · index 47%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDIYCOOLCold-climate score, best modelTRUENORTHCold-climate score, best model
Ducted, up to 1.5 tons87.0(50 is the typical model of its size class) (higher)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM8 of 9 models qualify · AHRI 21343326736.3(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models qualify · AHRI 218593150
Ducted, 2 tons79.6(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB7 of 7 models qualify · AHRI 20782556050.3(50 is the typical model of its size class)WLWHD(24)ND3MO4 of 4 models qualify · AHRI 218593151
Ducted, 2.5 to 3 tons80.0(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB10 of 15 models qualify · AHRI 21085734155.4(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD36AH2/A-D(U)4 of 4 models qualify · AHRI 218828997
Ducted, 3.5 to 4.5 tons86.5(50 is the typical model of its size class) (higher)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB12 of 16 models qualify · AHRI 21085734258.2(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)1 of 3 models qualify · AHRI 218828999
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC11 of 21 models qualify · AHRI 21085733474.0(50 is the typical model of its size class)WLWHD(18)ND3MO5 of 6 models qualify · AHRI 218593147
Non-ducted, 2 tons86.3(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB3 of 6 models qualify · AHRI 20782556377.3(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 218593148
Non-ducted, 2.5 to 3 tons80.2(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M4B7 of 15 models qualify · AHRI 20782559474.7(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models qualify · AHRI 218593146
Non-ducted, 3.5 to 4.5 tons76.8(50 is the typical model of its size class)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB5 of 8 models qualify · AHRI 210857346No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDIYCOOLAll-around score, best modelTRUENORTHAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB9 of 9 models have all five ratings · AHRI 20782555731.8(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models have all five ratings · AHRI 218593150
Ducted, 2 tons80.2(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB8 of 8 models have all five ratings · AHRI 20782556060.8(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD24AH2/A-D(U)5 of 5 models have all five ratings · AHRI 218828996
Ducted, 2.5 to 3 tons75.4(50 is the typical model of its size class) (higher)ES-27Z-M3B14 of 14 models have all five ratings · AHRI 21085740553.0(50 is the typical model of its size class)WLWHD(30)ND3MO3 of 3 models have all five ratings · AHRI 218593152
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M5B15 of 15 models have all five ratings · AHRI 20782559863.3(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)3 of 3 models have all five ratings · AHRI 218828999
Ducted, 5 tons and up42.0(50 is the typical model of its size class)ACIQ-60-EHPBwith ducted air handler ACIQ-60AHB1 of 1 models have all five ratings · AHRI 213433261No models in this size class
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC21 of 21 models have all five ratings · AHRI 21085733458.6(50 is the typical model of its size class)WLWHD(18)ND3MO6 of 6 models have all five ratings · AHRI 218593147
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB6 of 6 models have all five ratings · AHRI 20782555372.2(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models have all five ratings · AHRI 218593148
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M4B13 of 15 models have all five ratings · AHRI 20782559470.9(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models have all five ratings · AHRI 218593146
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class)ACIQ-48Z-HH-M5B8 of 8 models have all five ratings · AHRI 207825597No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDIYCOOLTRUENORTH
COP at 5°Fbeats 92% · 2.21ACIQ-24ZPL-HP230BNon-ducted, 2 tonsbeats 89% · 2.21WLWHD(18)ND3MONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 144%SC-09ZPL-HP230Non-ducted, up to 1.5 tonsbeats 86% · 89%WLWHD(30)ND3MODucted, 2.5 to 3 tons
HSPF2beats 99% · 10.3ACIQ-48ZPL-HP230BDucted, 3.5 to 4.5 tonsbeats 82% · 10.0WLWHD(36)ND3MONon-ducted, 2.5 to 3 tons
SEER2beats 99% · 20.9ACIQ-48Z-HH-M5BDucted, 3.5 to 4.5 tonsbeats 77% · 17.0WLUD60W/A-D(U)Ducted, 3.5 to 4.5 tons
EER2beats 99% · 16.6SC-09ZPL-HP230Non-ducted, up to 1.5 tonsbeats 84% · 12.5WLWHD(30)ND3MONon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 99% · 56,500 Btu/hACIQ-60ZPL-HP230BNon-ducted, 3.5 to 4.5 tonsbeats 85% · 13,800 Btu/hWLWHD(18)ND3MONon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
DIYCOOL vs TRUENORTH: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • DIYCOOL (median, middle 50%)
  • TRUENORTH (median, middle 50%)
Heating capacity, % of its 47°F maximum70%71%COP at maximum capacity1.911.80

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
DIYCOOL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
DIYCOOL, 47°F53100%100%100%100%100%
DIYCOOL, 17°F5365%68%76%83%91%
DIYCOOL, 5°F5355%58%70%79%83%
DIYCOOL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
DIYCOOL, 47°F532.833.183.373.49
DIYCOOL, 17°F532.012.092.212.32.44
DIYCOOL, 5°F531.81.831.9122.08
TRUENORTH: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F17100%100%100%100%100%
TRUENORTH, 17°F1767%73%84%88%91%
TRUENORTH, 5°F1757%61%71%75%77%
TRUENORTH: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F172.942.993.173.273.32
TRUENORTH, 17°F1722.082.32.412.46
TRUENORTH, 5°F171.771.81.81.842.14

Source: NEEP ccASHP list · as of