Measured against models of the same size and duct type, ForestAir scores higher on 4 of the 6 ratings. DUOHOME has 22 outdoor models, ForestAir has 22 outdoor models. DUOHOME and ForestAir have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
DUOHOME and ForestAir on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ForestAir scores higher on 4 of the 6 ratings.
  • DUOHOME
  • ForestAir
  • Other ranked manufacturers
DUOHOMEForestAir

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDUOHOMEForestAir
Efficiency index52%median —57%median —
COP at 5°F51% (higher)median 1.9943% (higher)median 1.80
Capacity retention at 5°F38%median 66%54%median 77%
HSPF261% (higher)median 9.334% (higher)median 9.0
SEER257%median 20.058%median 21.8
EER244%median 10.746%median 12.0
Heating capacity at 5°F43%median 14,800 Btu/h54%median 13,200 Btu/h
Outdoor models2222
AHRI certifications3724

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDUOHOMEForestAir
CEE 2025 Tier 1 (Split ASHP)59.1%13 models68.2%15 models
CEE 2026 Tier 1 (Split ASHP)50%11 models68.2%15 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)27.3%6 models54.5%12 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models13.6%3 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 5 groups where both have models
  • DUOHOME
  • ForestAir
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDUOHOMEForestAir
Ducted, up to 1.5 tons2 · index 69%None
Ducted, 2 tons1 · index 84%1 · index 61%
Ducted, 2.5–3 tons4 · index 55%None
Ducted, 3.5–4.5 tons4 · index 53%1 · index 63%
Ducted, 5 tons and up1 · index 55%None
Non-ducted, up to 1.5 tons9 · index 49%14 · index 56%
Non-ducted, 2 tons2 · index 47%4 · index 58%
Non-ducted, 2.5–3 tons5 · index 49%2 · index 51%
Non-ducted, 3.5–4.5 tons3 · index 43%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDUOHOMECold-climate score, best modelForestAirCold-climate score, best model
Ducted, up to 1.5 tons52.0(50 is the typical model of its size class)D2OA-18HFN1-M1 of 2 models qualify · AHRI 211911389No models in this size class
Ducted, 2 tons80.3(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ducted air handler DTIU-24HWFN1-M1 of 1 models qualify · AHRI 214797741No models in this size class
Ducted, 2.5–3 tons57.8(50 is the typical model of its size class) (higher)D3OJ-27HFN1-M1 of 4 models qualify · AHRI 21191139255.3(50 is the typical model of its size class)FAD36W/A-D(U)with ducted air handler FAD36AH2/A-D(U)1 of 1 models qualify · AHRI 208939392
Ducted, 3.5–4.5 tonsNone on this board (0 of 4 models qualify)58.1(50 is the typical model of its size class)FAD60W/A-D(U)with ducted air handler FAD48AH2/A-D(U)1 of 1 models qualify · AHRI 208939393
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, up to 1.5 tons63.3(50 is the typical model of its size class)DOX230-09HFN1-MW5Wwith ductless indoor unit DCA3U-09HRFN1-M(C)3 of 9 models qualify · AHRI 21487572368.8(50 is the typical model of its size class) (higher)FA-H12-D23TL/O-ESwith ductless indoor unit FA-H12-D23TL/I-ES9 of 14 models qualify · AHRI 207797362
Non-ducted, 2 tons59.4(50 is the typical model of its size class) (higher)DOD33-24HFN1-MT0Wwith ductless indoor unit DCD1-24HRFN1-MT0W(GA)1 of 2 models qualify · AHRI 21487572449.7(50 is the typical model of its size class)FGH-24ES/E25-Owith ductless indoor unit FGH-24ES/E25-I1 of 4 models qualify · AHRI 211624984
Non-ducted, 2.5–3 tons50.1(50 is the typical model of its size class)D3OJ-27HFN1-M1 of 5 models qualify · AHRI 211911391None on this board (0 of 2 models qualify)
Non-ducted, 3.5–4.5 tonsNone on this board (0 of 3 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDUOHOMEAll-around score, best modelForestAirAll-around score, best model
Ducted, up to 1.5 tons78.5(50 is the typical model of its size class)DOX430-18HFN1-MU0Wwith ducted air handler DTIU-18HWFN1-M2 of 2 models have all five ratings · AHRI 214797740No models in this size class
Ducted, 2 tons83.8(50 is the typical model of its size class) (higher)DOD33-24HFN1-MT0Wwith ducted air handler DTIU-24HWFN1-M1 of 1 models have all five ratings · AHRI 21479774160.8(50 is the typical model of its size class)FAD36W/A-D(U)with ducted air handler FAD24AH2/A-D(U)1 of 1 models have all five ratings · AHRI 208939391
Ducted, 2.5–3 tons71.7(50 is the typical model of its size class)D3OJ-27HFN1-M3 of 4 models have all five ratings · AHRI 211911392No models in this size class
Ducted, 3.5–4.5 tons63.5(50 is the typical model of its size class) (higher)D5OG-48HFN1-M3 of 4 models have all five ratings · AHRI 21191139863.3(50 is the typical model of its size class)FAD60W/A-D(U)with ducted air handler FAD48AH2/A-D(U)1 of 1 models have all five ratings · AHRI 208939393
Ducted, 5 tons and up54.5(50 is the typical model of its size class)DOE30U-60HFN1-Mwith ducted air handler DHG-60HWFN1-MW1 of 1 models have all five ratings · AHRI 206314613No models in this size class
Non-ducted, up to 1.5 tons71.6(50 is the typical model of its size class) (higher)DOX230-12HFN1-MV5Wwith ductless indoor unit DCA3U-12HRFN1-M(C)9 of 9 models have all five ratings · AHRI 21487572870.8(50 is the typical model of its size class)FA-H12-D23TL/O-ESwith ductless indoor unit FA-H12-D23TL/I-ES10 of 14 models have all five ratings · AHRI 207797362
Non-ducted, 2 tons66.3(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ductless indoor unit DCD1-24HRFN1-MT0W(GA)2 of 2 models have all five ratings · AHRI 21487572471.1(50 is the typical model of its size class) (higher)FGH-24ES/E25-Owith ductless indoor unit FGH-24ES/E25-I3 of 4 models have all five ratings · AHRI 211624984
Non-ducted, 2.5–3 tons67.1(50 is the typical model of its size class) (higher)D3OJ-27HFN1-M4 of 5 models have all five ratings · AHRI 21191139151.2(50 is the typical model of its size class)FA-H36-D21TL/O4-ES1 of 2 models have all five ratings · AHRI 207804203
Non-ducted, 3.5–4.5 tons48.3(50 is the typical model of its size class)D5OG-48HFN1-M3 of 3 models have all five ratings · AHRI 211911397No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDUOHOMEForestAir
COP at 5°Fbeats 92% · 2.28DOX230-12HFN1-MV5WNon-ducted, up to 1.5 tonsbeats 89% · 2.21FA-H18-D23TL/O-ESNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 73% · 59%DOE30U-60HFN1-MDucted, 5 tons and upbeats 73% · 81%FAD60W/A-D(U)Ducted, 3.5–4.5 tons
HSPF2beats 98% · 11.2DOD33-24HFN1-MT0WDucted, 2 tonsbeats 73% · 9.0FAD60W/A-D(U)Ducted, 3.5–4.5 tons
SEER2beats 98% · 21.0D3OJ-27HFN1-MDucted, 2.5–3 tonsbeats 97% · 24.0FGH-24ES/E25-ONon-ducted, 2 tons
EER2beats 85% · 12.5DOD33-24HFN1-MT0WDucted, 2 tonsbeats 90% · 14.7FGH-09ES/E25-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 78% · 35,600 Btu/hDOE30U-60HFN1-MDucted, 5 tons and upbeats 86% · 14,500 Btu/hFGH-18ES/E25-ONon-ducted, up to 1.5 tons