Skip to content

DUOHOME vs SLIMAIR heat pumps

Measured against models of the same size and duct type, SLIMAIR scores higher on 5 of the 6 ratings. DUOHOME has 22 outdoor models, SLIMAIR has 54 outdoor models. DUOHOME and SLIMAIR have no QMID on file and are not ranked. They share hardware: 11 equipment families appear under both names.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
DUOHOME and SLIMAIR on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, SLIMAIR scores higher on 5 of the 6 ratings.
  • DUOHOME
  • SLIMAIR
  • Other ranked manufacturers
DUOHOMESLIMAIR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDUOHOMESLIMAIR
Efficiency index53%median —59%median —
COP at 5°F52% (higher)median 1.9949% (higher)median 1.91
Capacity retention at 5°F39%median 66%59%median 73%
HSPF261%median 9.371%median 9.5
SEER257%median 20.065%median 19.8
EER244%median 10.749%median 11.0
Heating capacity at 5°F44%median 14,800 Btu/h58%median 20,000 Btu/h
Outdoor models2254
AHRI certifications37100

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDUOHOMESLIMAIR
CEE 2025 Tier 1 (Split ASHP)59.1%13 models66.7%36 models
CEE 2026 Tier 1 (Split ASHP)50%11 models59.3%32 models
CEE Advanced Tier (Split ASHP)0%0 models1.9%1 models
Xcel Energy Colorado cold-climate ASHP (2025)27.3%6 models50%27 models
DOE Cold Climate Heat Pump Challenge0%0 models1.9%1 models
ENERGY STAR Cold Climate0%0 models42.6%23 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • DUOHOME
  • SLIMAIR
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDUOHOMESLIMAIR
Ducted, up to 1.5 tons2 · index 69%10 · index 63%
Ducted, 2 tons1 · index 84%4 · index 71%
Ducted, 2.5 to 3 tons4 · index 55%11 · index 56%
Ducted, 3.5 to 4.5 tons4 · index 53%11 · index 58%
Ducted, 5 tons and up1 · index 54%2 · index 50%
Non-ducted, up to 1.5 tons9 · index 50%18 · index 62%
Non-ducted, 2 tons2 · index 48%4 · index 59%
Non-ducted, 2.5 to 3 tons5 · index 50%8 · index 55%
Non-ducted, 3.5 to 4.5 tons3 · index 43%4 · index 51%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDUOHOMECold-climate score, best modelSLIMAIRCold-climate score, best model
Ducted, up to 1.5 tons52.6(50 is the typical model of its size class)D2OA-18HFN1-M1 of 2 models qualify · AHRI 21191138975.2(50 is the typical model of its size class) (higher)SHC09VH2AGwith ducted air handler SHD09VC2AG8 of 10 models qualify · AHRI 214606463
Ducted, 2 tons80.6(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ducted air handler DTIU-24HWFN1-M1 of 1 models qualify · AHRI 21479774180.6(50 is the typical model of its size class)SHC24VE2AGwith ducted air handler SHD24VC2AG4 of 4 models qualify · AHRI 214606459
Ducted, 2.5 to 3 tons57.6(50 is the typical model of its size class)D3OJ-27HFN1-M1 of 4 models qualify · AHRI 21191139280.0(50 is the typical model of its size class) (higher)SHC36VH2AGwith ducted air handler SHD36VC2AG6 of 11 models qualify · AHRI 214606467
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 4 models qualify)86.5(50 is the typical model of its size class)SHC48VH2AGwith ducted air handler SHD48VC2AG6 of 11 models qualify · AHRI 214606468
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons64.6(50 is the typical model of its size class)DOX230-09HFN1-MW5Wwith ductless indoor unit DCA3U-09HRFN1-M(C)3 of 9 models qualify · AHRI 21487572386.6(50 is the typical model of its size class) (higher)SHC09VE2AGwith ductless indoor unit SHM09VE2AG12 of 18 models qualify · AHRI 208447936
Non-ducted, 2 tons61.4(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ductless indoor unit DCD1-24HRFN1-MT0W(GA)1 of 2 models qualify · AHRI 21487572487.1(50 is the typical model of its size class) (higher)SHC24VH2AGwith ductless indoor unit SHLZ24VC2AG3 of 4 models qualify · AHRI 214728303
Non-ducted, 2.5 to 3 tons51.5(50 is the typical model of its size class)D3OJ-27HFN1-M1 of 5 models qualify · AHRI 21191139174.4(50 is the typical model of its size class) (higher)SHC4Z36VE2AG4 of 8 models qualify · AHRI 213886044
Non-ducted, 3.5 to 4.5 tonsNone on this board (0 of 3 models qualify)80.7(50 is the typical model of its size class)SHC5Z48VE2AG2 of 4 models qualify · AHRI 213886047

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDUOHOMEAll-around score, best modelSLIMAIRAll-around score, best model
Ducted, up to 1.5 tons78.8(50 is the typical model of its size class)DOX430-18HFN1-MU0Wwith ducted air handler DTIU-18HWFN1-M2 of 2 models have all five ratings · AHRI 21479774085.4(50 is the typical model of its size class) (higher)SHC09VH2AGwith ducted air handler SHD09VC2AG10 of 10 models have all five ratings · AHRI 214606463
Ducted, 2 tons84.0(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ducted air handler DTIU-24HWFN1-M1 of 1 models have all five ratings · AHRI 21479774184.0(50 is the typical model of its size class)SHC24VE2AGwith ducted air handler SHD24VC2AG4 of 4 models have all five ratings · AHRI 214606459
Ducted, 2.5 to 3 tons71.7(50 is the typical model of its size class)D3OJ-27HFN1-M3 of 4 models have all five ratings · AHRI 21191139274.7(50 is the typical model of its size class) (higher)SHC3Z27VE2AG10 of 11 models have all five ratings · AHRI 213886042
Ducted, 3.5 to 4.5 tons63.5(50 is the typical model of its size class)D5OG-48HFN1-M3 of 4 models have all five ratings · AHRI 21191139882.1(50 is the typical model of its size class) (higher)SHC5Z48VE2AG10 of 11 models have all five ratings · AHRI 213886048
Ducted, 5 tons and up54.3(50 is the typical model of its size class)DOE30U-60HFN1-Mwith ducted air handler DHG-60HWFN1-MW1 of 1 models have all five ratings · AHRI 20631461357.2(50 is the typical model of its size class) (higher)SHC60VC2AGwith ducted air handler SHD60VC2AG2 of 2 models have all five ratings · AHRI 214606462
Non-ducted, up to 1.5 tons72.1(50 is the typical model of its size class)DOX230-12HFN1-MV5Wwith ductless indoor unit DCA3U-12HRFN1-M(C)9 of 9 models have all five ratings · AHRI 21487572887.1(50 is the typical model of its size class) (higher)SHC09VE2AGwith ductless indoor unit SHM09VE2AG18 of 18 models have all five ratings · AHRI 208447936
Non-ducted, 2 tons67.4(50 is the typical model of its size class)DOD33-24HFN1-MT0Wwith ductless indoor unit DCD1-24HRFN1-MT0W(GA)2 of 2 models have all five ratings · AHRI 21487572471.9(50 is the typical model of its size class) (higher)SHCD24VC2AGwith ductless indoor unit SHMZ24VC2AGAlso listed as SHC24VH2AG4 of 4 models have all five ratings · AHRI 208447943
Non-ducted, 2.5 to 3 tons68.0(50 is the typical model of its size class)D3OJ-27HFN1-M4 of 5 models have all five ratings · AHRI 21191139171.5(50 is the typical model of its size class) (higher)SHC4Z36VE2AG7 of 8 models have all five ratings · AHRI 213886044
Non-ducted, 3.5 to 4.5 tons48.3(50 is the typical model of its size class)D5OG-48HFN1-M3 of 3 models have all five ratings · AHRI 21191139773.9(50 is the typical model of its size class) (higher)SHC5Z48VE2AG4 of 4 models have all five ratings · AHRI 213886047

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDUOHOMESLIMAIR
COP at 5°Fbeats 92% · 2.28DOX230-12HFN1-MV5WNon-ducted, up to 1.5 tonsbeats 97% · 2.22SHC24VE2AGNon-ducted, 2 tons
Capacity retention at 5°Fbeats 72% · 59%DOE30U-60HFN1-MDucted, 5 tons and upbeats 95% · 113%SHC09VE2AGNon-ducted, up to 1.5 tons
HSPF2beats 98% · 11.2DOD33-24HFN1-MT0WDucted, 2 tonsbeats 99% · 10.3SHC48VH2AGDucted, 3.5 to 4.5 tons
SEER2beats 98% · 21.0D3OJ-27HFN1-MDucted, 2.5 to 3 tonsbeats 99% · 20.9SHC5Z48VE2AGDucted, 3.5 to 4.5 tons
EER2beats 85% · 12.5DOD33-24HFN1-MT0WDucted, 2 tonsbeats 95% · 15.8SHCD09VC2AGAlso listed as SHC09VH2AGNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 77% · 12,900 Btu/hD2OA-18HFN1-MNon-ducted, up to 1.5 tonsbeats 98% · 53,000 Btu/hSHC55VH2AGDucted, 3.5 to 4.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
DUOHOME vs SLIMAIR: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • DUOHOME (median, middle 50%)
  • SLIMAIR (median, middle 50%)
Heating capacity, % of its 47°F maximum58%66%COP at maximum capacity1.951.91

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
DUOHOME: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
DUOHOME, 47°F18100%100%100%100%100%
DUOHOME, 17°F1863%66%68%71%75%
DUOHOME, 5°F1852%55%58%63%65%
DUOHOME: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
DUOHOME, 47°F182.632.773.083.233.54
DUOHOME, 17°F181.952.062.172.252.4
DUOHOME, 5°F181.81.811.952.052.29
SLIMAIR: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
SLIMAIR, 47°F49100%100%100%100%100%
SLIMAIR, 17°F4964%67%75%85%93%
SLIMAIR, 5°F4954%57%66%78%83%
SLIMAIR: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
SLIMAIR, 47°F492.642.873.093.213.51
SLIMAIR, 17°F491.942.012.22.32.4
SLIMAIR, 5°F491.81.831.9122.11

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter