Skip to content

Durastar vs ROVSUN heat pumps

Measured against models of the same size and duct type, Durastar scores higher on 6 of the 6 ratings. Durastar has 35 outdoor models, ROVSUN has 21 outdoor models. ROVSUN has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Durastar and ROVSUN on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Durastar scores higher on 6 of the 6 ratings.
  • Durastar
  • ROVSUN
  • Other ranked manufacturers
DurastarROVSUN

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDurastarROVSUN
Efficiency index59% (higher)median — · 8th ranked33% (higher)median —
COP at 5°F55% (higher)median 2.00 · 14th ranked25% (higher)median 1.80
Capacity retention at 5°F56% (higher)median 65% · 14th ranked35% (higher)median 66%
HSPF266% (higher)median 9.4 · 7th ranked15% (higher)median 8.0
SEER263% (higher)median 19.0 · 7th ranked31% (higher)median 19.0
EER257% (higher)median 11.7 · 9th ranked22% (higher)median 10.0
Heating capacity at 5°F54% (higher)median 20,400 Btu/h · 13th ranked46% (higher)median 11,600 Btu/h
Outdoor models3521
AHRI certifications29321

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDurastarROVSUN
CEE 2025 Tier 1 (Split ASHP)57.1%20 models33.3%7 models
CEE 2026 Tier 1 (Split ASHP)51.4%18 models33.3%7 models
CEE Advanced Tier (Split ASHP)2.9%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)45.7%16 models23.8%5 models
DOE Cold Climate Heat Pump Challenge2.9%1 models0%0 models
ENERGY STAR Cold Climate60%21 models14.3%3 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • Durastar
  • ROVSUN
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDurastarROVSUN
Ducted, up to 1.5 tons10 · index 59%None
Ducted, 2 tons3 · index 71%None
Ducted, 2.5 to 3 tons9 · index 53%None
Ducted, 3.5 to 4.5 tons10 · index 53%None
Ducted, 5 tons and up2 · index 55%None
Non-ducted, up to 1.5 tons8 · index 70%19 · index 34%
Non-ducted, 2 tons2 · index 67%1 · index —
Non-ducted, 2.5 to 3 tons5 · index 64%1 · index 30%
Non-ducted, 3.5 to 4.5 tons4 · index 51%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDurastarCold-climate score, best modelROVSUNCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class)DRA1H09S1Awith ducted air handler DRAD09F1A7 of 10 models qualify · AHRI 210568115No models in this size class
Ducted, 2 tons80.6(50 is the typical model of its size class)DRA1U24S1Bwith ducted air handler DRAD24F1A2 of 3 models qualify · AHRI 207787145No models in this size class
Ducted, 2.5 to 3 tons66.8(50 is the typical model of its size class)DRA3H28M1A3 of 9 models qualify · AHRI 210568215No models in this size class
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)DRA5H48M1A2 of 10 models qualify · AHRI 210568221No models in this size class
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tons86.6(50 is the typical model of its size class) (higher)DRA1U09S1Bwith ductless indoor unit DRAW09F1B7 of 8 models qualify · AHRI 20778713049.6(50 is the typical model of its size class)TSC-12HA2/I3XI23-Owith ductless indoor unit TSC-12HA2/I3XI23-I5 of 19 models qualify · AHRI 213927362
Non-ducted, 2 tons87.1(50 is the typical model of its size class)DRA1H24S1Awith ductless indoor unit DRAC24F1B2 of 2 models qualify · AHRI 210568114None on this board (0 of 1 models qualify)
Non-ducted, 2.5 to 3 tons74.4(50 is the typical model of its size class)DRA4H36M1A4 of 5 models qualify · AHRI 210568217None on this board (0 of 1 models qualify)
Non-ducted, 3.5 to 4.5 tons80.7(50 is the typical model of its size class)DRA5H48M1A2 of 4 models qualify · AHRI 210568220No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDurastarAll-around score, best modelROVSUNAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class)DRA1H09S1Awith ducted air handler DRAD09F1A10 of 10 models have all five ratings · AHRI 210568115No models in this size class
Ducted, 2 tons84.0(50 is the typical model of its size class)DRA1U24S1Bwith ducted air handler DRAD24F1A3 of 3 models have all five ratings · AHRI 207787145No models in this size class
Ducted, 2.5 to 3 tons74.7(50 is the typical model of its size class)DRA3H28M1A9 of 9 models have all five ratings · AHRI 210568215No models in this size class
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)DRA5H48M1A10 of 10 models have all five ratings · AHRI 210568221No models in this size class
Ducted, 5 tons and up68.3(50 is the typical model of its size class)DRHP15A60AJ2ANwith ducted air handler F,PE*DD19602 of 2 models have all five ratings · AHRI 214077297No models in this size class
Non-ducted, up to 1.5 tons87.1(50 is the typical model of its size class) (higher)DRA1U09S1Bwith ductless indoor unit DRAW09F1B8 of 8 models have all five ratings · AHRI 20778713061.3(50 is the typical model of its size class)TSC-12HA2/I3XI23-Owith ductless indoor unit TSC-12HA2/I3XI23-I10 of 19 models have all five ratings · AHRI 213927362
Non-ducted, 2 tons72.9(50 is the typical model of its size class)DRA1U24S1Bwith ductless indoor unit DRAF24F1A2 of 2 models have all five ratings · AHRI 207787146None on this board (0 of 1 models have all five ratings)
Non-ducted, 2.5 to 3 tons71.5(50 is the typical model of its size class) (higher)DRA4H36M1A5 of 5 models have all five ratings · AHRI 21056821729.6(50 is the typical model of its size class)TMSC-27HA2/I2XI19-O1 of 1 models have all five ratings · AHRI 213927368
Non-ducted, 3.5 to 4.5 tons73.9(50 is the typical model of its size class)DRA5H48M1A4 of 4 models have all five ratings · AHRI 210568220No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDurastarROVSUN
COP at 5°Fbeats 98% · 2.45DRA1U12S1BNon-ducted, up to 1.5 tonsbeats 26% · 1.80TSC-18HA2/I2AXI19-OAlso listed as TSC-18HA2/I2XI19-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 95% · 113%DRA1U09S1BNon-ducted, up to 1.5 tonsbeats 62% · 76%TSC-12HA2/I3XI23-ONon-ducted, up to 1.5 tons
HSPF2beats 98% · 12.0DRA1H09S1ADucted, up to 1.5 tonsbeats 58% · 9.5TSC-12HA2/I3XI23-ONon-ducted, up to 1.5 tons
SEER2beats 99% · 20.9DRA5H48M1ADucted, 3.5 to 4.5 tonsbeats 73% · 23.0TSC-09HA1/I3XI22-ONon-ducted, up to 1.5 tons
EER2beats 95% · 15.8DRA1H09S1ANon-ducted, up to 1.5 tonsbeats 68% · 13.0TSC-12HA2/I3XI23-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hDRA2H18M1ANon-ducted, up to 1.5 tonsbeats 79% · 13,000 Btu/hTMSC-18HA2/I2XI20-ONon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy