Skip to content

ECO-AIR vs Pioneer heat pumps

Measured against models of the same size and duct type, ECO-AIR scores higher on 6 of the 6 ratings. ECO-AIR has 61 outdoor models, Pioneer has 61 outdoor models. ECO-AIR has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ECO-AIR and Pioneer on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ECO-AIR scores higher on 6 of the 6 ratings.
  • ECO-AIR
  • Pioneer
  • Other ranked manufacturers
ECO-AIRPioneer

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingECO-AIRPioneer
Efficiency index57% (higher)median —53% (higher)median — · 16th ranked
COP at 5°F52% (higher)median 1.9848% (higher)median 1.85 · 20th ranked
Capacity retention at 5°F54% (higher)median 68%43% (higher)median 67% · 23rd ranked
HSPF268% (higher)median 9.452% (higher)median 9.0 · 13th ranked
SEER261% (higher)median 19.056% (higher)median 19.0 · 11th ranked
EER246% (higher)median 10.544% (higher)median 11.0 · 24th ranked
Heating capacity at 5°F57% (higher)median 20,000 Btu/h44% (higher)median 14,400 Btu/h · 20th ranked
Outdoor models6161
AHRI certifications14698

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardECO-AIRPioneer
CEE 2025 Tier 1 (Split ASHP)59%36 models67.2%41 models
CEE 2026 Tier 1 (Split ASHP)55.7%34 models62.3%38 models
CEE Advanced Tier (Split ASHP)1.6%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)42.6%26 models45.9%28 models
DOE Cold Climate Heat Pump Challenge1.6%1 models0%0 models
ENERGY STAR Cold Climate47.5%29 models27.9%17 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • ECO-AIR
  • Pioneer
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeECO-AIRPioneer
Ducted, up to 1.5 tons12 · index 61%4 · index 69%
Ducted, 2 tons4 · index 70%2 · index 65%
Ducted, 2.5 to 3 tons16 · index 53%8 · index 59%
Ducted, 3.5 to 4.5 tons11 · index 56%6 · index 58%
Ducted, 5 tons and up2 · index 50%1 · index 76%
Non-ducted, up to 1.5 tons18 · index 55%31 · index 49%
Non-ducted, 2 tons5 · index 54%7 · index 55%
Non-ducted, 2.5 to 3 tons11 · index 59%11 · index 43%
Non-ducted, 3.5 to 4.5 tons6 · index 52%3 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeECO-AIRCold-climate score, best modelPioneerCold-climate score, best model
Ducted, up to 1.5 tons87.0(50 is the typical model of its size class) (higher)MOX430U-18HFN1-Mwith ducted air handler MVBE-18HWFN1-MM3E9 of 12 models qualify · AHRI 21330790871.0(50 is the typical model of its size class)YN009GMFI22RPEwith ducted air handler RB009GMFILDFHD3 of 4 models qualify · AHRI 208141951
Ducted, 2 tons80.6(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M4 of 4 models qualify · AHRI 21164405280.6(50 is the typical model of its size class)YN024GMFI22RPEwith ducted air handler RB024GMFILDFHD2 of 2 models qualify · AHRI 208141954
Ducted, 2.5 to 3 tons80.0(50 is the typical model of its size class) (higher)MOE30U-36HFN1-M(GA)with ducted air handler MTI-36HWFN1-M7 of 16 models qualify · AHRI 21164406675.2(50 is the typical model of its size class)YH3036GHFD18R2with ducted air handler DR036GHFD18HT23 of 8 models qualify · AHRI 207028595
Ducted, 3.5 to 4.5 tons86.5(50 is the typical model of its size class) (higher)MOE30U-48HFN1-M-[X](GA)with ducted air handler MTI-48HWFN1-M7 of 12 models qualify · AHRI 21164406775.8(50 is the typical model of its size class)YD060GMFI20MR2with ducted air handler DC060GMFI20HT22 of 6 models qualify · AHRI 205301886
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)70.2(50 is the typical model of its size class)PRB-60HWD1N1-M191 of 1 models qualify · AHRI 212527998
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)MOX230-09HFN1-MW5Wwith ductless indoor unit MSEPB-06HRFN1-MY5W9 of 18 models qualify · AHRI 20812186385.5(50 is the typical model of its size class)YN009GMFI22RPEwith ductless indoor unit CK009GMFILCFHD16 of 31 models qualify · AHRI 213349746
Non-ducted, 2 tons87.1(50 is the typical model of its size class) (higher)MOD30-24HFN1-MU0Wwith ductless indoor unit MCD1-24HRFN1-MT0W(GA)2 of 5 models qualify · AHRI 21164407175.6(50 is the typical model of its size class)YN024GMFI22RPEwith ductless indoor unit UB024GMFILCFHD3 of 7 models qualify · AHRI 208141957
Non-ducted, 2.5 to 3 tons87.5(50 is the typical model of its size class) (higher)M4OX630-36HFN1-M1X4 of 11 models qualify · AHRI 21330791551.5(50 is the typical model of its size class)YN030GMFI22M3E1 of 11 models qualify · AHRI 208121964
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class) (higher)M5OG-48HFN1-M-[X]3 of 6 models qualify · AHRI 20931964756.2(50 is the typical model of its size class)YN048GMFI18RUEwith ductless indoor unit UB048GMFILCFHD1 of 3 models qualify · AHRI 208121960

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeECO-AIRAll-around score, best modelPioneerAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)MOX330-09HFN1-MY5Wwith ducted air handler MTIU-09HWFN1-M12 of 12 models have all five ratings · AHRI 21164406278.8(50 is the typical model of its size class)YN018GMFI22RPEwith ducted air handler RB018GMFILDFHD4 of 4 models have all five ratings · AHRI 208141953
Ducted, 2 tons84.0(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M4 of 4 models have all five ratings · AHRI 21164405284.0(50 is the typical model of its size class)YN024GMFI22RPEwith ducted air handler RB024GMFILDFHD2 of 2 models have all five ratings · AHRI 208141954
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class) (higher)M4OX630-36HFN1-M1X15 of 16 models have all five ratings · AHRI 21330791676.1(50 is the typical model of its size class)YD036GMFI20MR2with ducted air handler DC036GMFI20HT27 of 8 models have all five ratings · AHRI 205301885
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)M5OG-48HFN1-M-[X]11 of 12 models have all five ratings · AHRI 20931964879.3(50 is the typical model of its size class)YD060GMFI20MR2with ducted air handler DC060GMFI20HT25 of 6 models have all five ratings · AHRI 205301886
Ducted, 5 tons and up57.2(50 is the typical model of its size class)MOE30U-60HFN1-M(GA)(X)with ducted air handler MHG-60HWFN1-MW1 of 1 models have all five ratings · AHRI 21164405575.5(50 is the typical model of its size class) (higher)PRB-60HWD1N1-M191 of 1 models have all five ratings · AHRI 212527998
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)MOX230-09HFN1-MW5Wwith ductless indoor unit MSEPB-06HRFN1-MY5W18 of 18 models have all five ratings · AHRI 20812186382.0(50 is the typical model of its size class)YN009GHFI25RPHwith ductless indoor unit WF009GHFI25HLH27 of 31 models have all five ratings · AHRI 211583711
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)MOD30-24HFN1-MU0Wwith ductless indoor unit MSEPD-24HRFN1-MU0W5 of 5 models have all five ratings · AHRI 20812186772.9(50 is the typical model of its size class)YN024GMFI22RPEwith ductless indoor unit UB024GMFILCFHD6 of 7 models have all five ratings · AHRI 208141957
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class) (higher)M4OI-36HFN1-M10 of 11 models have all five ratings · AHRI 20931964468.0(50 is the typical model of its size class)YN030GMFI22M3E8 of 11 models have all five ratings · AHRI 208121964
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class) (higher)M5OG-48HFN1-M-[X]6 of 6 models have all five ratings · AHRI 20931964748.3(50 is the typical model of its size class)YN050GMFI22M5E2 of 3 models have all five ratings · AHRI 208121970

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingECO-AIRPioneer
COP at 5°Fbeats 98% · 2.45MOX230-12HFN1-MV5WNon-ducted, up to 1.5 tonsbeats 96% · 2.38YN018GMFI22RPENon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 111%MOX430U-18HFN1-MDucted, up to 1.5 tonsbeats 90% · 70%PRB-60HWD1N1-M19Ducted, 5 tons and up
HSPF2beats 99% · 10.3MOE30U-48HFN1-M-[X](GA)Ducted, 3.5 to 4.5 tonsbeats 98% · 11.2YN024GMFI22RPEDucted, 2 tons
SEER2beats 99% · 20.9M5OG-48HFN1-M-[X]Ducted, 3.5 to 4.5 tonsbeats 98% · 21.0YN030GMFI22M3EDucted, 2.5 to 3 tons
EER2beats 98% · 16.2MOX330-09HFN1-MY5WNon-ducted, up to 1.5 tonsbeats 89% · 14.5YN009GHFI25RPHNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 41,000 Btu/hMOE30U-36HFN1-M(GA)Non-ducted, 2.5 to 3 tonsbeats 89% · 40,000 Btu/hPRB-60HWD1N1-M19Ducted, 5 tons and up

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
ECO-AIR vs Pioneer: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,707 models (37.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • ECO-AIR (median, middle 50%)
  • Pioneer (median, middle 50%)
Heating capacity, % of its 47°F maximum63%63%COP at maximum capacity1.981.98

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,707100%100%100%100%100%
All rated models, 17°F3,70765%68%76%83%92%
All rated models, 5°F3,70755%58%67%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7072.642.873.13.323.53
All rated models, 17°F3,7071.982.052.22.342.49
All rated models, 5°F3,7071.81.831.922.032.21
ECO-AIR: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
ECO-AIR, 47°F51100%100%100%100%100%
ECO-AIR, 17°F5163%67%72%78%83%
ECO-AIR, 5°F5153%56%63%74%81%
ECO-AIR: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
ECO-AIR, 47°F512.762.893.063.333.51
ECO-AIR, 17°F5122.12.212.312.45
ECO-AIR, 5°F511.81.841.9822.2
Pioneer: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Pioneer, 47°F23100%100%100%100%100%
Pioneer, 17°F2364%67%71%81%93%
Pioneer, 5°F2353%57%63%72%82%
Pioneer: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Pioneer, 47°F232.722.913.153.483.57
Pioneer, 17°F232.012.122.242.392.4
Pioneer, 5°F231.81.881.982.122.3

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter