Skip to content

ELIOS vs ENERGI AIR heat pumps

Measured against models of the same size and duct type, ELIOS scores higher on 5 of the 6 ratings. ELIOS has 45 outdoor models, ENERGI AIR has 46 outdoor models. ELIOS and ENERGI AIR have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ELIOS and ENERGI AIR on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ELIOS scores higher on 5 of the 6 ratings.
  • ELIOS
  • ENERGI AIR
  • Other ranked manufacturers
ELIOSENERGI A…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingELIOSENERGI AIR
Efficiency index59% (higher)median —39% (higher)median —
COP at 5°F51% (higher)median 1.9840% (higher)median 1.92
Capacity retention at 5°F62% (higher)median 81%13% (higher)median 46%
HSPF272% (higher)median 9.721% (higher)median 7.0
SEER259% (higher)median 18.931% (higher)median 15.2
EER246%median 10.567%median 11.4
Heating capacity at 5°F63% (higher)median 23,765 Btu/h12% (higher)median 14,800 Btu/h
Outdoor models4546
AHRI certifications1143,367

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardELIOSENERGI AIR
CEE 2025 Tier 1 (Split ASHP)62.2%28 models6.5%3 models
CEE 2026 Tier 1 (Split ASHP)55.6%25 models2.2%1 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)46.7%21 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate55.6%25 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 5 groups where both have models
  • ELIOS
  • ENERGI AIR
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeELIOSENERGI AIR
Ducted, up to 1.5 tons10 · index 65%3 · index 39%
Ducted, 2 tons4 · index 74%8 · index 37%
Ducted, 2.5–3 tons10 · index 60%15 · index 39%
Ducted, 3.5–4.5 tons10 · index 57%18 · index 42%
Ducted, 5 tons and up3 · index 51%2 · index 36%
Non-ducted, up to 1.5 tons13 · index 61%None
Non-ducted, 2 tons4 · index 53%None
Non-ducted, 2.5–3 tons11 · index 56%None
Non-ducted, 3.5–4.5 tons8 · index 52%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeELIOSCold-climate score, best modelENERGI AIRCold-climate score, best model
Ducted, up to 1.5 tons74.9(50 is the typical model of its size class)DEA09HOS28230E8with ducted air handler DUA09HIDU230X59 of 10 models qualify · AHRI 207742452None on this board (0 of 3 models qualify)
Ducted, 2 tons80.3(50 is the typical model of its size class)DEA24HOS25230E8with ducted air handler DUA24HIDU230X54 of 4 models qualify · AHRI 207742448None on this board (0 of 8 models qualify)
Ducted, 2.5–3 tons79.9(50 is the typical model of its size class)DE36HOS25230E3with ducted air handler DM36HIDU230X5Also listed as DEA36HOS28230E86 of 10 models qualify · AHRI 206853242None on this board (0 of 15 models qualify)
Ducted, 3.5–4.5 tons86.4(50 is the typical model of its size class)DE48HOS25230E3with ducted air handler DM48HIDU230X5Also listed as DEA48HOS28230E86 of 10 models qualify · AHRI 206853243None on this board (0 of 18 models qualify)
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons89.3(50 is the typical model of its size class)DEA06HOS28230E8with ductless indoor unit DEA06HIW25230E8Also listed as DEA09HOS25230E88 of 13 models qualify · AHRI 207742428No models in this size class
Non-ducted, 2 tons86.1(50 is the typical model of its size class)DEA24HOS28230E8with ductless indoor unit DUA24HICU230X53 of 4 models qualify · AHRI 207742442No models in this size class
Non-ducted, 2.5–3 tons79.3(50 is the typical model of its size class)DEA36HOM25230X33 of 11 models qualify · AHRI 207742466No models in this size class
Non-ducted, 3.5–4.5 tons76.2(50 is the typical model of its size class)DEA48HOM25230X33 of 8 models qualify · AHRI 207742469No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeELIOSAll-around score, best modelENERGI AIRAll-around score, best model
Ducted, up to 1.5 tons85.2(50 is the typical model of its size class) (higher)DEA09HOS28230E8with ducted air handler DUA09HIDU230X510 of 10 models have all five ratings · AHRI 20774245240.0(50 is the typical model of its size class)GSZB401810A*with ducted air handler CAPTA3626*4A*+MBVC1201**-1AAlso listed as GSZM401810A3 of 3 models have all five ratings · AHRI 212836127
Ducted, 2 tons83.8(50 is the typical model of its size class) (higher)DEA24HOS25230E8with ducted air handler DUA24HIDU230X54 of 4 models have all five ratings · AHRI 20774244859.1(50 is the typical model of its size class)GSZC702410A*with ducted air handler AMVT30BP1400A6 of 8 models have all five ratings · AHRI 211942121
Ducted, 2.5–3 tons75.4(50 is the typical model of its size class) (higher)DEA27HOM23230X29 of 10 models have all five ratings · AHRI 20774247664.2(50 is the typical model of its size class)GSZC703610A*with ducted air handler CAPTA4230*4A*+MBVC2001**-1A11 of 15 models have all five ratings · AHRI 211942151
Ducted, 3.5–4.5 tons82.0(50 is the typical model of its size class) (higher)DEA48HOM25230X39 of 10 models have all five ratings · AHRI 20774247068.2(50 is the typical model of its size class)GSZC704810A*with ducted air handler CAPT4961*4A*+MBVC2001**-1A10 of 18 models have all five ratings · AHRI 211942189
Ducted, 5 tons and up54.5(50 is the typical model of its size class) (higher)DE60HOS18230E5with ducted air handler DE60HIDU230X5Also listed as DEC60HOS18230S5A3 of 3 models have all five ratings · AHRI 20263579251.5(50 is the typical model of its size class)GPHH56041A*2 of 2 models have all five ratings · AHRI 211941593
Non-ducted, up to 1.5 tons92.0(50 is the typical model of its size class)DEA06HOS28230E8with ductless indoor unit DEA06HIW25230E8Also listed as DEA09HOS25230E813 of 13 models have all five ratings · AHRI 207742428No models in this size class
Non-ducted, 2 tons77.5(50 is the typical model of its size class)DEA24HOS25230E8with ductless indoor unit DEA24HIW25230E84 of 4 models have all five ratings · AHRI 207742427No models in this size class
Non-ducted, 2.5–3 tons82.8(50 is the typical model of its size class)DEA36HOM25230X38 of 11 models have all five ratings · AHRI 207742466No models in this size class
Non-ducted, 3.5–4.5 tons77.9(50 is the typical model of its size class)DEA48HOM25230X36 of 8 models have all five ratings · AHRI 207742469No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingELIOSENERGI AIR
COP at 5°Fbeats 98% · 2.45DEA12HOS25230E8Non-ducted, up to 1.5 tonsbeats 94% · 2.51GPHH56041A*Ducted, 5 tons and up
Capacity retention at 5°Fbeats 95% · 103%DEA36HOS28230E8Non-ducted, 2.5–3 tonsbeats 28% · 42%GPHH56041A*Ducted, 5 tons and up
HSPF2beats 99% · 10.3DE48HOS25230E3Also listed as DEA48HOS28230E8Ducted, 3.5–4.5 tonsbeats 55% · 8.2GSZC704810A*Ducted, 3.5–4.5 tons
SEER2beats 99% · 24.6DEA27HOM23230X2Non-ducted, 2.5–3 tonsbeats 81% · 17.2GSZC704810A*Ducted, 3.5–4.5 tons
EER2beats 97% · 14.0DEA24HOS25230E8Non-ducted, 2 tonsbeats 92% · 12.5GSZB404810A*Ducted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 98% · 41,000 Btu/hDEA36HOS28230E8Non-ducted, 2.5–3 tonsbeats 24% · 23,000 Btu/hGPHH56041A*Ducted, 5 tons and up

More comparisons