Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Enerwave vs Everwell: heat pump ratings compared
Against heat pumps of the same size and type, a typical Enerwave model beats 22% and a typical Everwell model 27%. Everwell rates slightly higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Enerwave
22%
of similar heat pumps beaten by its typical model
Well below average14 models listed
Everwell
27%
of similar heat pumps beaten by its typical model
Well below average14 models listed
- Efficiency on a 5°F dayCOP at 5°FEnerwave: Beats 17%Everwell: Beats 37%
- Heating power kept at 5°FCapacity at 5°F vs 47°FEnerwave: Beats 31%Everwell: Beats 20%
- Winter-long heating efficiencyHSPF2Enerwave: Beats 36%Everwell: Beats 28%
- Summer-long cooling efficiencySEER2Enerwave: Beats 18%Everwell: Beats 26%
- Hot-day cooling efficiencyEER2Enerwave: Beats 15%Everwell: Beats 30%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Enerwave
- 0%
- Everwell
- 14%
Xcel CC
- Enerwave
- 0%
- Everwell
- 14%
CEE Advanced
- Enerwave
- 0%
- Everwell
- 0%
ENERGY STAR CC
- Enerwave
- 0%
- Everwell
- 0%
All-around best, ducted up to 1.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Enerwave
- 1W2SH06AEWEnerwave0.5 tons · 6,000 Btu/h · DuctedNot a cold-climate pick: keeps 51% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 52% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.16 (COP at 5°F)
- Great
- Winter efficiency
- 12.6 (HSPF2)
- Top 10%
- Cooling efficiency
- 15.7 (SEER2)
- Below the middle
- Hot-day cooling
- 10.4 (EER2)
- Below the middle
- 2VD3SD18EWEnerwaveAlso listed as VD3SD27EW0.5 tons · 8,900 Btu/h · DuctedCold-climate pick, score 43.8Meets none of the standards tracked here
- Heat kept at 5°F
- 73% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.72 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.9 (HSPF2)
- Good
- Cooling efficiency
- 14.4 (SEER2)
- Below the middle
- Hot-day cooling
- 11.0 (EER2)
- Below the middle
- 3W3PHEF8BEWEnerwave1 ton · 9,000 Btu/h · DuctedNot a cold-climate pick: keeps 62% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 62% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.76 (COP at 5°F)
- Below the middle
- Winter efficiency
- 8.6 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.8 (SEER2)
- Below the middle
- Hot-day cooling
- 11.2 (EER2)
- Below the middle
Everwell
- 1CAC1814HA15with ducted air handler A(E,F)W18J+TDREverwell1.5 tons · 17,100 Btu/h · DuctedNot a cold-climate pick: keeps 42% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 42% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.78 (COP at 5°F)
- Below the middle
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 14.3 (SEER2)
- Below the middle
- Hot-day cooling
- 11.4 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view