Skip to content

Ephoca vs Midea heat pumps

Measured against models of the same size and duct type, Midea scores higher on 6 of the 6 ratings. Ephoca has 30 outdoor models, Midea has 408 outdoor models. Ephoca has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Ephoca and Midea on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Midea scores higher on 6 of the 6 ratings.
  • Ephoca
  • Midea
  • Other ranked manufacturers
EphocaMidea

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingEphocaMidea
Efficiency index20%median —55%median — · 12th ranked
COP at 5°F5%median 1.7249%median 1.93 · 19th ranked
Capacity retention at 5°F48%median 73%52%median 69% · 16th ranked
HSPF238%median 9.263%median 9.2 · 9th ranked
SEER27%median 13.958%median 19.0 · 9th ranked
EER215%median 10.647%median 11.0 · 19th ranked
Heating capacity at 5°F5%median 6,200 Btu/h53%median 20,000 Btu/h · 15th ranked
Outdoor models30408
AHRI certifications301,554

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardEphocaMidea
CEE 2025 Tier 1 (Split ASHP)0%0 models60.3%246 models
CEE 2026 Tier 1 (Split ASHP)0%0 models57.4%234 models
CEE Advanced Tier (Split ASHP)0%0 models2.7%11 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models45.1%184 models
DOE Cold Climate Heat Pump Challenge0%0 models2.7%11 models
ENERGY STAR Cold Climate13.3%4 models37.3%152 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • Ephoca
  • Midea
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsNon-ducted, 5 tons and up2.0137 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeEphocaMidea
Ducted, up to 1.5 tons26 · index 20%48 · index 60%
Ducted, 2 tonsNone34 · index 59%
Ducted, 2.5 to 3 tonsNone100 · index 55%
Ducted, 3.5 to 4.5 tonsNone67 · index 56%
Ducted, 5 tons and upNone21 · index 49%
Non-ducted, up to 1.5 tons4 · index 25%122 · index 54%
Non-ducted, 2 tonsNone31 · index 54%
Non-ducted, 2.5 to 3 tonsNone95 · index 55%
Non-ducted, 3.5 to 4.5 tonsNone50 · index 49%
Non-ducted, 5 tons and upNone1 · index 10%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeEphocaCold-climate score, best modelMideaCold-climate score, best model
Ducted, up to 1.5 tons41.8(50 is the typical model of its size class)AVP10*4*1Also listed as AVP10*4*2, AVE10*4*2, AVK10*4*2, AXP10*4*1 and 4 more23 of 26 models qualify · AHRI 21360733287.0(50 is the typical model of its size class) (higher)MOX430U-18HFN1-Mwith ducted air handler MVBE-18HWFN1-MM3E41 of 49 models qualify · AHRI 213156951
Ducted, 2 tonsNo models in this size class80.6(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M30 of 33 models qualify · AHRI 206330133
Ducted, 2.5 to 3 tonsNo models in this size class84.7(50 is the typical model of its size class)MOE30U-32HFN1-M-[X]with ducted air handler MTI-32HWFN1-M49 of 101 models qualify · AHRI 205823026
Ducted, 3.5 to 4.5 tonsNo models in this size class86.5(50 is the typical model of its size class)MOE30U-48HFN1-M-[X]with ducted air handler MTI-48HWFN1-MAlso sold as CTMorley MOU-A48LH-2; also listed as MOE30U-48HFN1-M-[X](GA)34 of 66 models qualify · AHRI 204829821
Ducted, 5 tons and upNo models in this size class70.2(50 is the typical model of its size class)MRB-60HWD1N1-M19Also listed as MRD-60HWD1N1-M182 of 21 models qualify · AHRI 202680577
Non-ducted, up to 1.5 tons32.1(50 is the typical model of its size class)APP10*4*1with ductless indoor unit APP10*4*1Also listed as APP10*4*2, APK10*4*24 of 4 models qualify · AHRI 21360732492.7(50 is the typical model of its size class) (higher)MOX230-09HFN1-MY2Wwith ductless indoor unit MFA2U-09HRFN1-MY6W58 of 122 models qualify · AHRI 209248925
Non-ducted, 2 tonsNo models in this size class87.1(50 is the typical model of its size class)38MARBQ24AA3with ductless indoor unit 40MBCAQ24XA3Also sold as MDV MOD30-24HFN1-MU0W, CTMorley MOU-A24H-2, MDV MOD30-24HFN1-MU0W-L; also listed as DLCSRBH24AAK18 of 31 models qualify · AHRI 207683320
Non-ducted, 2.5 to 3 tonsNo models in this size class91.3(50 is the typical model of its size class)M4OX630-36HFN1-M1X*31 of 95 models qualify · AHRI 213301877
Non-ducted, 3.5 to 4.5 tonsNo models in this size class87.6(50 is the typical model of its size class)M5OG-42HFN1-M-[X]with ductless indoor unit MSEPB-09HRFN1-MY5W(GA)29 of 50 models qualify · AHRI 207617657
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeEphocaAll-around score, best modelMideaAll-around score, best model
Ducted, up to 1.5 tons29.4(50 is the typical model of its size class)AVP10*4*1Also listed as AVP10*4*2, AVE10*4*2, AVK10*4*2, AXP10*4*1 and 4 more26 of 26 models have all five ratings · AHRI 21360733285.4(50 is the typical model of its size class) (higher)38MARBQ09AA3with ducted air handler 40MBDQ09---3Also sold as MDV MOX330-09HFN1-MY5W, CTMorley MOU-A09H-2; also listed as DLCSRBH09AAK51 of 51 models have all five ratings · AHRI 206350372
Ducted, 2 tonsNo models in this size class84.0(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M31 of 31 models have all five ratings · AHRI 206330133
Ducted, 2.5 to 3 tonsNo models in this size class83.7(50 is the typical model of its size class)M4OX630-36HFN1-M1XAlso listed as M4OX630-36HFN1-M1X95 of 100 models have all five ratings · AHRI 213301875
Ducted, 3.5 to 4.5 tonsNo models in this size class84.7(50 is the typical model of its size class)M5OG-42HFN1-M-[X]61 of 67 models have all five ratings · AHRI 207617659
Ducted, 5 tons and upNo models in this size class75.5(50 is the typical model of its size class)MRB-60HWD1N1-M19Also listed as MRD-60HWD1N1-M1820 of 21 models have all five ratings · AHRI 202680577
Non-ducted, up to 1.5 tons24.8(50 is the typical model of its size class)APP10*4*1with ductless indoor unit APP10*4*1Also listed as APP10*4*2, APK10*4*24 of 4 models have all five ratings · AHRI 21360732492.7(50 is the typical model of its size class) (higher)MOX230-09HFN1-MW5W-Lwith ductless indoor unit MSEPB-06HRFN1-MY5W119 of 122 models have all five ratings · AHRI 213199198
Non-ducted, 2 tonsNo models in this size class84.9(50 is the typical model of its size class)38MARBQ24AA3with ductless indoor unit DHMAHBQ24XA3Also sold as MDV MOD30-24HFN1-MU0W, MDV MOD30-24HFN1-MU0W-L; also listed as DLCSRBH24AAK31 of 31 models have all five ratings · AHRI 206350321
Non-ducted, 2.5 to 3 tonsNo models in this size class86.7(50 is the typical model of its size class)M4OX630-36HFN1-M1X*85 of 95 models have all five ratings · AHRI 213301877
Non-ducted, 3.5 to 4.5 tonsNo models in this size class85.9(50 is the typical model of its size class)M5OG-42HFN1-M-[X]with ductless indoor unit MSEPB-09HRFN1-MY5W(GA)47 of 50 models have all five ratings · AHRI 207617657
Non-ducted, 5 tons and upNo models in this size class10.0(50 is the typical model of its size class)MDV-V60WMN1T*1 of 1 models have all five ratings · AHRI 212604264

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingEphocaMidea
COP at 5°Fbeats 8% · 1.75APP10*4*1Also listed as APP10*4*2, APK10*4*2Non-ducted, up to 1.5 tonsbeats 98% · 2.45MOX230-09HFN1-MY2WNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 70% · 81%APP10*4*1Also listed as APP10*4*2, APK10*4*2Non-ducted, up to 1.5 tonsbeats 99% · 137%MOX330-09HFN1-MY6WNon-ducted, up to 1.5 tons
HSPF2beats 73% · 9.9AVP10*4*1Also listed as AVP10*4*2, AVE10*4*2, AVK10*4*2, AXP10*4*1 and 4 moreDucted, up to 1.5 tonsbeats 100% · 15.038MPRBQ09AA3Also sold as MDV MOX430-09HFN1-MZG5W; also listed as DLCPRBH09AAKNon-ducted, up to 1.5 tons
SEER2beats 9% · 14.4AVP10*4*1Also listed as AVP10*4*2, AVE10*4*2, AVK10*4*2, AXP10*4*1 and 4 moreDucted, up to 1.5 tonsbeats 100% · 26.038MGHBQ30DA3Also sold as MDV M4OG-30HFN1-M; also listed as MMCMHAQ30DA3Non-ducted, 2.5 to 3 tons
EER2beats 35% · 11.2APP10*4*1Also listed as APP10*4*2, APK10*4*2Non-ducted, up to 1.5 tonsbeats 99% · 16.5MOX430-09HFN1-MZG5WNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 12% · 6,700 Btu/hAPP10*4*1Also listed as APP10*4*2, APK10*4*2Non-ducted, up to 1.5 tonsbeats 100% · 46,000 Btu/hMOE30U-32HFN1-M-[X]Ducted, 2.5 to 3 tons

More comparisons

    Send feedback

    Attached to every report