Both views use the same certified data. This device remembers your choice.
Everwell vs HITACHI heat pumps
Measured against models of the same size and duct type, HITACHI scores higher on 6 of the 6 ratings. Everwell has 27 outdoor models, HITACHI has 27 outdoor models. Everwell and HITACHI have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Everwell
- HITACHI
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Everwell | HITACHI |
|---|---|---|
| Efficiency index | 27%median — | 58%median — |
| COP at 5°F | 24%median 1.80 | 73%median 2.25 |
| Capacity retention at 5°F | 12%median 45% | 59%median 76% |
| HSPF2 | 16%median 7.8 | 66%median 9.8 |
| SEER2 | 22%median 17.0 | 51%median 20.0 |
| EER2 | 27%median 10.0 | 53%median 12.5 |
| Heating capacity at 5°F | 17%median 12,750 Btu/h | 50%median 14,500 Btu/h |
| Outdoor models | 27 | 27 |
| AHRI certifications | 31 | 47 |
Share of models meeting each standard
| Standard | Everwell | HITACHI |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 74.1%20 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 74.1%20 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 66.7%18 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Everwell
- HITACHI
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Everwell | HITACHI |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index 14% | 4 · index 50% |
| Ducted, 2 tons | 2 · index 23% | 2 · index 56% |
| Ducted, 2.5 to 3 tons | 3 · index 30% | 3 · index 71% |
| Ducted, 3.5 to 4.5 tons | 5 · index 35% | 3 · index 66% |
| Non-ducted, up to 1.5 tons | 10 · index 15% | 15 · index 57% |
| Non-ducted, 2 tons | 2 · index — | 5 · index 58% |
| Non-ducted, 2.5 to 3 tons | 4 · index — | 4 · index 53% |
| Non-ducted, 3.5 to 4.5 tons | None | 2 · index 60% |
| Non-ducted, 5 tons and up | None | 1 · index 68% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | EverwellCold-climate score, best model | HITACHICold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 56.7(50 is the typical model of its size class)RAS-1.0PNNBDH1with ducted air handler RPIL-1.0PNN1DH2 of 4 models qualify · AHRI 206750852 |
| Ducted, 2 tons | None on this board (0 of 2 models qualify) | 65.2(50 is the typical model of its size class)RAS-3.0PNNBDH1with ducted air handler RPIM-3.0PNN1DH1 of 2 models qualify · AHRI 206750858 |
| Ducted, 2.5 to 3 tons | None on this board (0 of 3 models qualify) | 78.4(50 is the typical model of its size class)RAS-4.0PNNBDH1with ducted air handler RPIM-4.0PNN1DH2 of 3 models qualify · AHRI 206750860 |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 5 models qualify) | None on this board (0 of 3 models qualify) |
| Non-ducted, up to 1.5 tons | None on this board (0 of 10 models qualify) | 81.7(50 is the typical model of its size class)RAC-SH09WHLAEwith ductless indoor unit RAS-SH09RHLAE13 of 15 models qualify · AHRI 206907172 |
| Non-ducted, 2 tons | None on this board (0 of 2 models qualify) | 77.7(50 is the typical model of its size class)RAC-PH24WHLAEwith ductless indoor unit RAS-PH24PHLAE3 of 5 models qualify · AHRI 207200483 |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 4 models qualify) | 78.2(50 is the typical model of its size class)RAS-4.0PNNBDH1with ductless indoor unit RCI-4.0PNN1DH3 of 4 models qualify · AHRI 206750859 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | EverwellAll-around score, best model | HITACHIAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 13.9(50 is the typical model of its size class)CAC1813HA15with ducted air handler FAHC18HA151 of 1 models have all five ratings · AHRI 211603979 | 58.1(50 is the typical model of its size class) (higher)RAS-1.0PNNBDH1with ducted air handler RPIL-1.0PNN1DH3 of 4 models have all five ratings · AHRI 206750852 |
| Ducted, 2 tons | 23.3(50 is the typical model of its size class)CAC2413HA15with ducted air handler AHC24HA151 of 2 models have all five ratings · AHRI 212367468 | 55.9(50 is the typical model of its size class) (higher)RAS-3.0PNNBDH1with ducted air handler RPIM-3.0PNN1DH1 of 2 models have all five ratings · AHRI 206750858 |
| Ducted, 2.5 to 3 tons | 30.2(50 is the typical model of its size class)CAC3013HA15with ducted air handler AHC30HA152 of 3 models have all five ratings · AHRI 212367469 | 74.3(50 is the typical model of its size class) (higher)HVAHP036B21S*2 of 3 models have all five ratings · AHRI 203994975 |
| Ducted, 3.5 to 4.5 tons | 35.7(50 is the typical model of its size class)CAC4213HA15with ducted air handler AHC42HA153 of 5 models have all five ratings · AHRI 212367471 | 78.1(50 is the typical model of its size class) (higher)HVAHP048B21S*2 of 3 models have all five ratings · AHRI 203994976 |
| Non-ducted, up to 1.5 tons | 14.8(50 is the typical model of its size class)MGTH1823C-20with ductless indoor unit MGTH1823E-201 of 10 models have all five ratings · AHRI 205415927 | 72.6(50 is the typical model of its size class) (higher)RAC-SH09WHLAEwith ductless indoor unit RAS-SH09RHLAE14 of 15 models have all five ratings · AHRI 206907172 |
| Non-ducted, 2 tons | None on this board (0 of 2 models have all five ratings) | 74.0(50 is the typical model of its size class)RAC-PH24WHLAEwith ductless indoor unit RAS-PH24PHLAE4 of 5 models have all five ratings · AHRI 207200483 |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 4 models have all five ratings) | 75.7(50 is the typical model of its size class)HVAHP036B21S*3 of 4 models have all five ratings · AHRI 203994969 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 67.1(50 is the typical model of its size class)HVAHP048B21S*1 of 2 models have all five ratings · AHRI 203994970 |
| Non-ducted, 5 tons and up | No models in this size class | 68.1(50 is the typical model of its size class)HVAHP060B21S*1 of 1 models have all five ratings · AHRI 203994965 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Everwell | HITACHI |
|---|---|---|
| COP at 5°F | beats 29% · 1.80CAC3013HA15Ducted, 2.5 to 3 tons | beats 99% · 2.61HVAHP060B21S*Non-ducted, 5 tons and up |
| Capacity retention at 5°F | beats 16% · 61%MGTH1823C-20Non-ducted, up to 1.5 tons | beats 99% · 133%RAC-PH09WHLAENon-ducted, up to 1.5 tons |
| HSPF2 | beats 50% · 8.1CAC4813H18Ducted, 3.5 to 4.5 tons | beats 98% · 10.0HVAHP048B21S*Ducted, 3.5 to 4.5 tons |
| SEER2 | beats 65% · 16.0CAC4813H18Ducted, 3.5 to 4.5 tons | beats 93% · 23.1HVAHP048B21S*Non-ducted, 3.5 to 4.5 tons |
| EER2 | beats 76% · 12.2CAC2413H18Ducted, 2 tons | beats 100% · 16.7HVAHP048B21S*Non-ducted, 3.5 to 4.5 tons |
| Heating capacity at 5°F | beats 62% · 11,600 Btu/hMGTH1823C-20Non-ducted, up to 1.5 tons | beats 100% · 23,000 Btu/hRAC-PH18WHLAENon-ducted, up to 1.5 tons |