Skip to content

FRANKLIN vs Live cool heat pumps

Measured against models of the same size and duct type, FRANKLIN and Live cool split the 6 ratings 3 to 3. FRANKLIN has 74 outdoor models, Live cool has 6 outdoor models. FRANKLIN and Live cool have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
FRANKLIN and Live cool on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, FRANKLIN and Live cool split the 6 ratings 3 to 3.
  • FRANKLIN
  • Live cool
  • Other ranked manufacturers
FRANKLINLive cool

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFRANKLINLive cool
Efficiency index54%median —54%median —
COP at 5°F45% (higher)median 1.9227% (higher)median 1.80
Capacity retention at 5°F45%median 52%52%median 73%
HSPF244%median 7.847%median 9.0
SEER250%median 15.268%median 22.5
EER264% (higher)median 11.763% (higher)median 12.8
Heating capacity at 5°F42% (higher)median 17,300 Btu/h39% (higher)median 8,900 Btu/h
Outdoor models746
AHRI certifications3,9086

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFRANKLINLive cool
CEE 2025 Tier 1 (Split ASHP)33.8%25 models100%6 models
CEE 2026 Tier 1 (Split ASHP)31.1%23 models100%6 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)21.6%16 models66.7%4 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate18.9%14 models66.7%4 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • FRANKLIN
  • Live cool
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFRANKLINLive cool
Ducted, up to 1.5 tons10 · index 54%None
Ducted, 2 tons12 · index 52%None
Ducted, 2.5 to 3 tons21 · index 50%None
Ducted, 3.5 to 4.5 tons24 · index 49%None
Ducted, 5 tons and up3 · index 42%None
Non-ducted, up to 1.5 tons8 · index 63%5 · index 55%
Non-ducted, 2 tons2 · index 72%1 · index 48%
Non-ducted, 2.5 to 3 tons6 · index 65%None
Non-ducted, 3.5 to 4.5 tons1 · index 78%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFRANKLINCold-climate score, best modelLive coolCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class)MSH093E23MCAAwith ducted air handler MST093E21ADAA7 of 10 models qualify · AHRI 206900427No models in this size class
Ducted, 2 tons79.6(50 is the typical model of its size class)MSH243E23MCAAwith ducted air handler MST243E21ADAAAlso listed as MSH243F25MCAA2 of 12 models qualify · AHRI 206900430No models in this size class
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class)MST273F25MHAA5 of 21 models qualify · AHRI 214383443No models in this size class
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)MST483F25MHAA1 of 24 models qualify · AHRI 214383449No models in this size class
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)No models in this size class
Non-ducted, up to 1.5 tons77.3(50 is the typical model of its size class) (higher)MSH093F25MCAAwith ductless indoor unit MSH093F25AXAA8 of 8 models qualify · AHRI 21438343349.6(50 is the typical model of its size class)LWSM-12IR410AHS23with ductless indoor unit LWSM-12IR410AHS234 of 5 models qualify · AHRI 218037240
Non-ducted, 2 tons85.5(50 is the typical model of its size class)MSH243F25MCAAwith ductless indoor unit MSH243F25AXAA2 of 2 models qualify · AHRI 214383436None on this board (0 of 1 models qualify)
Non-ducted, 2.5 to 3 tons91.3(50 is the typical model of its size class)MST363F25MHAA3 of 6 models qualify · AHRI 214383445No models in this size class
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class)MST483F25MHAA1 of 1 models qualify · AHRI 214383448No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFRANKLINAll-around score, best modelLive coolAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class)MSH093E23MCAAwith ducted air handler MST093E21ADAA10 of 10 models have all five ratings · AHRI 206900427No models in this size class
Ducted, 2 tons80.2(50 is the typical model of its size class)MSH243E23MCAAwith ducted air handler MST243E21ADAAAlso listed as MSH243F25MCAA10 of 12 models have all five ratings · AHRI 206900430No models in this size class
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class)MST363F25MHAA16 of 21 models have all five ratings · AHRI 214383446No models in this size class
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)MST483F25MHAA17 of 24 models have all five ratings · AHRI 214383449No models in this size class
Ducted, 5 tons and up54.3(50 is the typical model of its size class)MSH603E18MCAAwith ducted air handler MST603E18ADAA3 of 3 models have all five ratings · AHRI 206900445No models in this size class
Non-ducted, up to 1.5 tons87.6(50 is the typical model of its size class) (higher)MSH093F25MCAAwith ductless indoor unit MSH093F25AXAA8 of 8 models have all five ratings · AHRI 21438343361.7(50 is the typical model of its size class)LWSM-09IR410AHS23with ductless indoor unit LWSM-09IR410AHS235 of 5 models have all five ratings · AHRI 218037239
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)MSH243F25MCAAwith ductless indoor unit MSH243F25AXAA2 of 2 models have all five ratings · AHRI 21438343647.6(50 is the typical model of its size class)LWSM-24IR410AHS20with ductless indoor unit LWSM-24IR410AHS201 of 1 models have all five ratings · AHRI 218037242
Non-ducted, 2.5 to 3 tons86.7(50 is the typical model of its size class)MST363F25MHAA5 of 6 models have all five ratings · AHRI 214383445No models in this size class
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class)MST483F25MHAA1 of 1 models have all five ratings · AHRI 214383448No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFRANKLINLive cool
COP at 5°Fbeats 95% · 2.51GPHH56041A*Ducted, 5 tons and upbeats 31% · 1.80LWSM-24IR410AHS20Non-ducted, 2 tons
Capacity retention at 5°Fbeats 98% · 103%MST273F25MHAANon-ducted, 2.5 to 3 tonsbeats 65% · 77%LWSM-09IR410AHS23Non-ducted, up to 1.5 tons
HSPF2beats 98% · 12.0MSH093E23MCAADucted, up to 1.5 tonsbeats 58% · 9.5LWSM-12IR410AHS23Non-ducted, up to 1.5 tons
SEER2beats 99% · 20.9MST483F25MHAADucted, 3.5 to 4.5 tonsbeats 79% · 23.5LWSM-09IR410AHS23Non-ducted, up to 1.5 tons
EER2beats 98% · 16.2MSH093F25MCAANon-ducted, up to 1.5 tonsbeats 68% · 13.0LWSM-09IR410AHS23Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hMST183E23MHAAAlso listed as MST183F25MHAANon-ducted, up to 1.5 tonsbeats 67% · 11,900 Btu/hLWSM-18IR410AHS21.5Non-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter