Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
FRASER - JOHNSTON vs TEMP SHIFT: heat pump ratings compared
One of these brands has too few models with every rating for an overall score; see each rating below.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
FRASER - JOHNSTON
—
of similar heat pumps beaten by its typical model
Not enough rated models18 models listed
TEMP SHIFT
66%
of similar heat pumps beaten by its typical model
Well above average19 models listed
- Efficiency on a 5°F dayCOP at 5°FFRASER - JOHNSTON: Not ratedTEMP SHIFT: Beats 52%
- Heating power kept at 5°FCapacity at 5°F vs 47°FFRASER - JOHNSTON: Not ratedTEMP SHIFT: Beats 79%
- Winter-long heating efficiencyHSPF2FRASER - JOHNSTON: Beats 8%TEMP SHIFT: Beats 79%
- Summer-long cooling efficiencySEER2FRASER - JOHNSTON: Beats 8%TEMP SHIFT: Beats 61%
- Hot-day cooling efficiencyEER2FRASER - JOHNSTON: Beats 48%TEMP SHIFT: Beats 62%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- FRASER - JOHNSTON
- 0%
- TEMP SHIFT
- 95%
Xcel CC
- FRASER - JOHNSTON
- 0%
- TEMP SHIFT
- 90%
CEE Advanced
- FRASER - JOHNSTON
- 0%
- TEMP SHIFT
- 5%
ENERGY STAR CC
- FRASER - JOHNSTON
- 0%
- TEMP SHIFT
- 0%
All-around best, ductless 2 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ductless, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
FRASER - JOHNSTON
No ductless, 2 tons model from FRASER - JOHNSTON.
TEMP SHIFT
- 1TSSZHH242R5with ductless indoor unit TSHW242R5TEMP SHIFT2 tons · 23,000 Btu/h · DuctlessCold-climate pick, score 89.4Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 13.3 (HSPF2)
- Top 10%
- Cooling efficiency
- 22.3 (SEER2)
- Good
- Hot-day cooling
- 12.5 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view