FRASER - JOHNSTON vs TEMP SHIFT heat pumps
Measured against models of the same size and duct type, TEMP SHIFT scores higher on 3 of the 6 ratings. FRASER - JOHNSTON has 18 outdoor models, TEMP SHIFT has 19 outdoor models. FRASER - JOHNSTON and TEMP SHIFT have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- FRASER - JOHNSTON
- TEMP SHIFT
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | FRASER - JOHNSTON | TEMP SHIFT |
|---|---|---|
| Efficiency index | —median — | 66%median — |
| COP at 5°F | —median — | 52%median 2.00 |
| Capacity retention at 5°F | —median — | 79%median 95% |
| HSPF2 | 8%median 6.7 | 79%median 10.2 |
| SEER2 | 8%median 13.4 | 61%median 19.4 |
| EER2 | 48%median 11.2 | 62%median 12.0 |
| Heating capacity at 5°F | —median — | 76%median 24,000 Btu/h |
| Outdoor models | 18 | 19 |
| AHRI certifications | 18 | 51 |
Share of models meeting each standard
| Standard | FRASER - JOHNSTON | TEMP SHIFT |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 94.7%18 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 94.7%18 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 5.3%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 89.5%17 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 5.3%1 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- FRASER - JOHNSTON
- TEMP SHIFT
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | FRASER - JOHNSTON | TEMP SHIFT |
|---|---|---|
| Ducted, 2.5–3 tons | 8 · index — | 4 · index 73% |
| Ducted, 3.5–4.5 tons | 10 · index — | 4 · index 65% |
| Ducted, up to 1.5 tons | None | 5 · index 76% |
| Ducted, 2 tons | None | 2 · index 70% |
| Non-ducted, up to 1.5 tons | None | 5 · index 74% |
| Non-ducted, 2 tons | None | 1 · index 68% |
| Non-ducted, 2.5–3 tons | None | 4 · index 44% |
| Non-ducted, 3.5–4.5 tons | None | 3 · index 52% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FRASER - JOHNSTONCold-climate score, best model | TEMP SHIFTCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 82.3(50 is the typical model of its size class)TSSZHH182R5with ducted air handler TSDT182R55 of 5 models qualify · AHRI 218426393 |
| Ducted, 2 tons | No models in this size class | 85.7(50 is the typical model of its size class)TSSZHH242R5with ducted air handler TSDT242R52 of 2 models qualify · AHRI 218426394 |
| Ducted, 2.5–3 tons | None on this board (0 of 8 models qualify) | 82.5(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models qualify · AHRI 218426402 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 10 models qualify) | 82.7(50 is the typical model of its size class)TSMZHH486Z2R54 of 4 models qualify · AHRI 218426405 |
| Non-ducted, up to 1.5 tons | No models in this size class | 93.8(50 is the typical model of its size class)TSSZHH062R5with ductless indoor unit TSHW062R55 of 5 models qualify · AHRI 218426379 |
| Non-ducted, 2 tons | No models in this size class | 89.4(50 is the typical model of its size class)TSSZHH242R5with ductless indoor unit TSCS242R51 of 1 models qualify · AHRI 218426389 |
| Non-ducted, 2.5–3 tons | No models in this size class | 72.6(50 is the typical model of its size class)TSMZHH365Z2R52 of 4 models qualify · AHRI 218426403 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 69.9(50 is the typical model of its size class)TSMZHH556Z2R53 of 3 models qualify · AHRI 218426409 |
All-around best
| Size and duct type | FRASER - JOHNSTONAll-around score, best model | TEMP SHIFTAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 86.5(50 is the typical model of its size class)TSSZHH092R5with ducted air handler TSDT092R55 of 5 models have all five ratings · AHRI 218426391 |
| Ducted, 2 tons | No models in this size class | 78.4(50 is the typical model of its size class)TSSZHH242R5with ducted air handler TSDT242R52 of 2 models have all five ratings · AHRI 218426394 |
| Ducted, 2.5–3 tons | None on this board (0 of 8 models have all five ratings) | 83.6(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models have all five ratings · AHRI 218426402 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 10 models have all five ratings) | 83.9(50 is the typical model of its size class)TSMZHH486Z2R54 of 4 models have all five ratings · AHRI 218426405 |
| Non-ducted, up to 1.5 tons | No models in this size class | 93.8(50 is the typical model of its size class)TSSZHH062R5with ductless indoor unit TSHW062R55 of 5 models have all five ratings · AHRI 218426379 |
| Non-ducted, 2 tons | No models in this size class | 72.9(50 is the typical model of its size class)TSSZHH242R5with ductless indoor unit TSHW242R51 of 1 models have all five ratings · AHRI 218426383 |
| Non-ducted, 2.5–3 tons | No models in this size class | 66.3(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models have all five ratings · AHRI 218426401 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 62.6(50 is the typical model of its size class)TSMZHH556Z2R53 of 3 models have all five ratings · AHRI 218426407 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | FRASER - JOHNSTON | TEMP SHIFT |
|---|---|---|
| COP at 5°F | — | beats 91% · 2.29TSSZHH062R5Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | — | beats 98% · 120%TSSZHH092R5Ducted, up to 1.5 tons |
| HSPF2 | beats 8% · 6.7WN048C***1*******1Also listed as WN048E***1*******1, WN048C***2*******1, WN048C***4*******1, WN048C***5*******1 and 3 moreDucted, 3.5–4.5 tons | beats 99% · 11.0TSMZHH486Z2R5Ducted, 3.5–4.5 tons |
| SEER2 | beats 8% · 13.4WN048C***1*******1Also listed as WN048E***1*******1, WN048C***2*******1, WN048C***4*******1, WN048C***5*******1 and 3 moreDucted, 3.5–4.5 tons | beats 96% · 20.4TSMZHH486Z2R5Ducted, 3.5–4.5 tons |
| EER2 | beats 50% · 11.2WN048C***1*******1Also listed as WN048E***1*******1, WN048C***2*******1, WN048C***4*******1, WN048C***5*******1 and 3 moreDucted, 3.5–4.5 tons | beats 96% · 16.0TSSZHH062R5Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | — | beats 97% · 39,000 Btu/hTSHCHH362R5Ducted, 2.5–3 tons |