FRASER - JOHNSTON heat pump efficiency: 18 outdoor models compared
FRASER - JOHNSTON has 18 heat pump outdoor models certified with this refrigerant group, in 18 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes FRASER - JOHNSTON makes. FRASER - JOHNSTON has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 18
- AHRI certifications
- 18
- Efficiency index
- —
- No model has all five ratings
- Meet CEE 2025
- 0%
- 0 models
How FRASER - JOHNSTON compares with comparable models
- FRASER - JOHNSTON
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index0 models scored | — | Not ranked | — |
| COP at 5°F0 models scored | — | Not ranked | — |
| Capacity retention at 5°F0 models scored | — | Not ranked | — |
| HSPF218 models scored | 8% | Not ranked | 6.7 |
| SEER218 models scored | 8% | Not ranked | 13.4 |
| EER218 models scored | 48% | Not ranked | 11.2 |
| Heating capacity at 5°F0 models scored | — | Not ranked | — |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- FRASER - JOHNSTON (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2.5–3 tons | 8 | — | — | 8% | 7% |
| Ducted, 3.5–4.5 tons | 10 | — | — | 8% | 8% |
Every FRASER - JOHNSTON model in the market
- FRASER - JOHNSTON models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top FRASER - JOHNSTON models
Cold-climate picks
No FRASER - JOHNSTON model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
No FRASER - JOHNSTON model has all five all-around ratings.
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | — | — | — | — | — |
| Capacity retention at 5°F | — | — | — | — | — |
| HSPF2 | WN048C***1*******1Also listed as WN048E***1*******1, WN048C***2*******1, WN048C***4*******1, WN048C***5*******1 and 3 more | 6.7 | Ducted, 3.5–4.5 tons | 8% | 216625251 |
| SEER2 | WN048C***1*******1Also listed as WN048E***1*******1, WN048C***2*******1, WN048C***4*******1, WN048C***5*******1 and 3 more | 13.4 | Ducted, 3.5–4.5 tons | 8% | 216625251 |
| EER2 | WN048C***1*******1Also listed as WN048E***1*******1, WN048C***2*******1, WN048C***4*******1, WN048C***5*******1 and 3 more | 11.2 | Ducted, 3.5–4.5 tons | 50% | 216625251 |
| Heating capacity at 5°F | — | — | — | — | — |
FRASER - JOHNSTON size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2.5–3 tons | None on this board (0 of 8 models qualify) | None on this board (0 of 8 models have all five ratings) |
| Ducted, 3.5–4.5 tons | None on this board (0 of 10 models qualify) | None on this board (0 of 10 models have all five ratings) |
Newest FRASER - JOHNSTON certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| WN060E***1*******1FRASER - JOHNSTON | 4.5 tons56,000 Btu/h · Ducted | — | — | 6.7 | 13.4 | None | 1 | 216625300 |
| WN060C***1*******1FRASER - JOHNSTON | 4.5 tons56,000 Btu/h · Ducted | — | — | 6.7 | 13.4 | None | 1 | 216625299 |
| WN048E***5*******1FRASER - JOHNSTON | 4 tons47,000 Btu/h · Ducted | — | — | 6.7 | 13.4 | None | 1 | 216625276 |
| WN048E***4*******1FRASER - JOHNSTON | 4 tons47,000 Btu/h · Ducted | — | — | 6.7 | 13.4 | None | 1 | 216625275 |
| WN048E***2*******1FRASER - JOHNSTON | 4 tons47,000 Btu/h · Ducted | — | — | 6.7 | 13.4 | None | 1 | 216625274 |
Compare FRASER - JOHNSTON
FRASER - JOHNSTON includes these brand names as listed in AHRI: FRASER - JOHNSTON. Standards are checked against published thresholds; program rules beyond ratings are not checked.