Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
TEMP SHIFT heat pump efficiency: 19 outdoor models compared
TEMP SHIFT has 19 heat pump outdoor models certified with this refrigerant group, in 51 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TEMP SHIFT makes. TEMP SHIFT has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 19
- AHRI certifications
- 51
- Efficiency index
- 66%
- Typical model vs same-size, same-type peers (28 models)
- Meet CEE 2025
- 94.7%
- 18 models
How TEMP SHIFT compares with comparable models
- TEMP SHIFT
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index28 models scored | 66% | Not ranked | — |
| COP at 5°F28 models scored | 52% | Not ranked | 2.00 |
| Capacity retention at 5°F28 models scored | 79% | Not ranked | 95% |
| HSPF228 models scored | 79% | Not ranked | 10.2 |
| SEER228 models scored | 61% | Not ranked | 19.4 |
| EER228 models scored | 62% | Not ranked | 12.0 |
| Heating capacity at 5°F28 models scored | 76% | Not ranked | 24,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 94.7% | 18 |
| CEE 2026 Tier 1 (Split ASHP) | 94.7% | 18 |
| CEE Advanced Tier (Split ASHP) | 5.3% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 89.5% | 17 |
| DOE Cold Climate Heat Pump Challenge | 5.3% | 1 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- TEMP SHIFT (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 5 | 76% | 61% | 84% | 74% |
| Ducted, 2 tons | 2 | 70% | 53% | 91% | 70% |
| Ducted, 2.5–3 tons | 4 | 73% | 47% | 88% | 71% |
| Ducted, 3.5–4.5 tons | 4 | 65% | 48% | 81% | 72% |
| Non-ducted, up to 1.5 tons | 5 | 74% | 61% | 87% | 63% |
| Non-ducted, 2 tons | 1 | 68% | 87% | 91% | 40% |
| Non-ducted, 2.5–3 tons | 4 | 44% | 38% | 48% | 39% |
| Non-ducted, 3.5–4.5 tons | 3 | 52% | 40% | 76% | 33% |
Every TEMP SHIFT model in the market
- TEMP SHIFT models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top TEMP SHIFT models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TSSZHH062R5TEMP SHIFTwith ductless indoor unit TSHW062R5 | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.29 | 14.6 | 7,500 | 25.3 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 218426379 | Non-ducted, up to 1.5 tons | 93.8 |
| 2TSSZHH242R5TEMP SHIFTwith ductless indoor unit TSCS242R5 | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26Xcel | 3 | 218426389 | Non-ducted, 2 tons | 89.4 |
| 3TSSZHH242R5TEMP SHIFTwith ducted air handler TSDT242R5 | 2 tons24,000 Btu/h · Ducted | 92% | 2.18 | 11.7 | 24,000 | 19.0 | CEE 25CEE 26Xcel | 3 | 218426394 | Ducted, 2 tons | 85.7 |
| 4TSMZHH486Z2R5TEMP SHIFT | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 48,000 | 20.4 | CEE 25CEE 26Xcel | 3 | 218426405 | Ducted, 3.5–4.5 tons | 82.7 |
| 5TSMZHH365Z2R5TEMP SHIFT | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 38,000 | 19.4 | CEE 25CEE 26Xcel | 3 | 218426402 | Ducted, 2.5–3 tons | 82.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TSSZHH062R5TEMP SHIFTwith ductless indoor unit TSHW062R5 | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.29 | 14.6 | 25.3 | 16.0 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 218426379 | Non-ducted, up to 1.5 tons | 93.8 | 93.8 | 93.9 | 93.8 |
| 2TSSZHH092R5TEMP SHIFTwith ducted air handler TSDT092R5 | 1 ton9,000 Btu/h · Ducted | 120% | 1.85 | 13.8 | 20.5 | 14.0 | CEE 25CEE 26Xcel | 3 | 218426391 | Ducted, up to 1.5 tons | 86.5 | 79.9 | 93.2 | 79.9 |
| 3TSMZHH486Z2R5TEMP SHIFT | 4 tons47,000 Btu/h · Ducted | 100% | 2.00 | 11.0 | 20.4 | 11.7 | CEE 25CEE 26Xcel | 3 | 218426405 | Ducted, 3.5–4.5 tons | 83.9 | 82.7 | 85.1 | 82.7 |
| 4TSMZHH365Z2R5TEMP SHIFT | 3 tons36,000 Btu/h · Ducted | 106% | 2.00 | 10.4 | 19.4 | 12.0 | CEE 25CEE 26Xcel | 3 | 218426402 | Ducted, 2.5–3 tons | 83.6 | 82.5 | 84.8 | 82.5 |
| 5TSMZHH556Z2R5TEMP SHIFT | 4.5 tons53,000 Btu/h · Ducted | 87% | 2.10 | 10.7 | 20.0 | 11.7 | CEE 25CEE 26Xcel | 3 | 218426408 | Ducted, 3.5–4.5 tons | 82.0 | 81.2 | 82.8 | 81.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TSSZHH062R5 | 2.29 | Non-ducted, up to 1.5 tons | 91% | 218426379 |
| Capacity retention at 5°F | TSSZHH092R5 | 120% | Ducted, up to 1.5 tons | 98% | 218426391 |
| HSPF2 | TSMZHH486Z2R5 | 11.0 | Ducted, 3.5–4.5 tons | 99% | 218426405 |
| SEER2 | TSMZHH486Z2R5 | 20.4 | Ducted, 3.5–4.5 tons | 96% | 218426405 |
| EER2 | TSSZHH062R5 | 16.0 | Non-ducted, up to 1.5 tons | 96% | 218426379 |
| Heating capacity at 5°F | TSHCHH362R5 | 39,000 Btu/h | Ducted, 2.5–3 tons | 97% | 218426362 |
TEMP SHIFT size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 82.3(50 is the typical model of its size class)TSSZHH182R5with ducted air handler TSDT182R55 of 5 models qualify · AHRI 218426393 | 86.5(50 is the typical model of its size class)TSSZHH092R5with ducted air handler TSDT092R55 of 5 models have all five ratings · AHRI 218426391 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class)TSSZHH242R5with ducted air handler TSDT242R52 of 2 models qualify · AHRI 218426394 | 78.4(50 is the typical model of its size class)TSSZHH242R5with ducted air handler TSDT242R52 of 2 models have all five ratings · AHRI 218426394 |
| Ducted, 2.5–3 tons | 82.5(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models qualify · AHRI 218426402 | 83.6(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models have all five ratings · AHRI 218426402 |
| Ducted, 3.5–4.5 tons | 82.7(50 is the typical model of its size class)TSMZHH486Z2R54 of 4 models qualify · AHRI 218426405 | 83.9(50 is the typical model of its size class)TSMZHH486Z2R54 of 4 models have all five ratings · AHRI 218426405 |
| Non-ducted, up to 1.5 tons | 93.8(50 is the typical model of its size class)TSSZHH062R5with ductless indoor unit TSHW062R55 of 5 models qualify · AHRI 218426379 | 93.8(50 is the typical model of its size class)TSSZHH062R5with ductless indoor unit TSHW062R55 of 5 models have all five ratings · AHRI 218426379 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class)TSSZHH242R5with ductless indoor unit TSCS242R51 of 1 models qualify · AHRI 218426389 | 72.9(50 is the typical model of its size class)TSSZHH242R5with ductless indoor unit TSHW242R51 of 1 models have all five ratings · AHRI 218426383 |
| Non-ducted, 2.5–3 tons | 72.6(50 is the typical model of its size class)TSMZHH365Z2R52 of 4 models qualify · AHRI 218426403 | 66.3(50 is the typical model of its size class)TSMZHH365Z2R54 of 4 models have all five ratings · AHRI 218426401 |
| Non-ducted, 3.5–4.5 tons | 69.9(50 is the typical model of its size class)TSMZHH556Z2R53 of 3 models qualify · AHRI 218426409 | 62.6(50 is the typical model of its size class)TSMZHH556Z2R53 of 3 models have all five ratings · AHRI 218426407 |
Newest TEMP SHIFT certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TSMZHH556Z2R5TEMP SHIFT | 4.5 tons52,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.05 | 87% | 10.7 | 20.7 | CEE 25CEE 26Xcel | 3 | 218426409 |
| TSMZHH486Z2R5TEMP SHIFT | 4 tons46,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 99% | 10.6 | 20.8 | CEE 25CEE 26Xcel | 3 | 218426406 |
| TSMZHH365Z2R5TEMP SHIFT | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.95 | 104% | 10.9 | 20.5 | CEE 25CEE 26Xcel | 3 | 218426403 |
| TSMZHH274Z2R5TEMP SHIFT | 2.5 tons27,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.95 | 99% | 9.8 | 20.0 | CEE 25CEE 26Xcel | 3 | 218426400 |
| TSMZHH183Z2R5TEMP SHIFT | 1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 90% | 10.0 | 20.5 | CEE 25CEE 26Xcel | 3 | 218426397 |
Compare TEMP SHIFT
TEMP SHIFT includes these brand names as listed in AHRI: TEMP SHIFT. Standards are checked against published thresholds; program rules beyond ratings are not checked.