Skip to content

Friedrich vs Fujitsu: heat pump ratings compared

Against heat pumps of the same size and type, a typical Friedrich model beats 39% and a typical Fujitsu model 53%. Fujitsu rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Friedrich

39%

of similar heat pumps beaten by its typical model

Well below average

188 models listed

Fujitsu

53%

of similar heat pumps beaten by its typical model

About average

179 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FFriedrich: Beats 46%Fujitsu: Beats 60%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FFriedrich: Beats 36%Fujitsu: Beats 48%
  • Winter-long heating efficiencyHSPF2Friedrich: Beats 31%Fujitsu: Beats 44%
  • Summer-long cooling efficiencySEER2Friedrich: Beats 34%Fujitsu: Beats 43%
  • Hot-day cooling efficiencyEER2Friedrich: Beats 37%Fujitsu: Beats 47%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Friedrich
    27%
    Fujitsu
    32%
  • Xcel CC

    Friedrich
    21%
    Fujitsu
    30%
  • CEE Advanced

    Friedrich
    1%
    Fujitsu
    8%
  • ENERGY STAR CC

    Friedrich
    22%
    Fujitsu
    27%

All-around best, ductless 2.5–3 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

Friedrich

  1. 1FPHMR27A3DFriedrich2.5 tons · 27,000 Btu/h · DuctlessCold-climate pick, score 50.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    12.9 (EER2)
    Great
    64.2score / 100Heating 50 · Cooling 78
  2. 2FPHMR36A3DFriedrich3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 53.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    10.0 (HSPF2)
    Good
    Cooling efficiency
    22.0 (SEER2)
    Good
    Hot-day cooling
    12.9 (EER2)
    Great
    61.7score / 100Heating 54 · Cooling 70
  3. 3FPHFR36A3Dwith ductless indoor unit FPHSC36A3DFriedrich3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 58.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Below the middle
    Cooling efficiency
    19.5 (SEER2)
    Below the middle
    Hot-day cooling
    12.0 (EER2)
    Good
    47.4score / 100Heating 58 · Cooling 37

Fujitsu

  1. 1AOUH30KUAH1with ductless indoor unit AUUH30KUASFujitsu2.5 tons · 30,000 Btu/h · DuctlessCold-climate pick, score 94.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.16 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    13.7 (EER2)
    Top 10%
    90.0score / 100Heating 95 · Cooling 86
  2. 2AOUK036MSAN7Fujitsu3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 80.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.32 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.3 (HSPF2)
    Good
    Cooling efficiency
    23.1 (SEER2)
    Great
    Hot-day cooling
    15.4 (EER2)
    Top 10%
    86.2score / 100Heating 80 · Cooling 92
  3. 3AOUH30KUAS1with ductless indoor unit AUUH30KUASFujitsu2.5 tons · 30,000 Btu/h · DuctlessCold-climate pick, score 80.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    88% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.12 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.6 (HSPF2)
    Great
    Cooling efficiency
    22.4 (SEER2)
    Good
    Hot-day cooling
    12.5 (EER2)
    Great
    75.3score / 100Heating 80 · Cooling 70

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view