Friedrich vs York heat pumps
Measured against models of the same size and duct type, York scores higher on 6 of the 6 ratings. Friedrich has 117 outdoor models, York has 179 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Friedrich
- York
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Friedrich | York |
|---|---|---|
| Efficiency index | 46%median — · 25th ranked | 51%median — · 21st ranked |
| COP at 5°F | 58%median 2.10 · 9th ranked | 69%median 2.20 · 5th ranked |
| Capacity retention at 5°F | 45%median 61% · 20th ranked | 50%median 69% · 18th ranked |
| HSPF2 | 31%median 7.5 · 26th ranked | 37%median 7.7 · 23rd ranked |
| SEER2 | 36%median 15.2 · 26th ranked | 38%median 15.2 · 24th ranked |
| EER2 | 39%median 10.6 · 26th ranked | 57%median 11.0 · 9th ranked |
| Heating capacity at 5°F | 39%median 15,600 Btu/h · 25th ranked | 49%median 24,200 Btu/h · 17th ranked |
| Outdoor models | 117 | 179 |
| AHRI certifications | 3,083 | 65,299 |
Share of models meeting each standard
| Standard | Friedrich | York |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 37.6%44 models | 26.3%47 models |
| CEE 2026 Tier 1 (Split ASHP) | 37.6%44 models | 26.3%47 models |
| CEE Advanced Tier (Split ASHP) | 1.7%2 models | 0.6%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.6%37 models | 25.7%46 models |
| DOE Cold Climate Heat Pump Challenge | 1.7%2 models | 0.6%1 models |
| ENERGY STAR Cold Climate | 28.2%33 models | 2.2%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Friedrich
- York
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Friedrich | York |
|---|---|---|
| Ducted, up to 1.5 tons | 21 · index 27% | 8 · index 42% |
| Ducted, 2 tons | 16 · index 45% | 17 · index 47% |
| Ducted, 2.5–3 tons | 22 · index 52% | 53 · index 51% |
| Ducted, 3.5–4.5 tons | 28 · index 47% | 71 · index 60% |
| Ducted, 5 tons and up | 7 · index — | 19 · index 50% |
| Non-ducted, up to 1.5 tons | 19 · index 55% | 9 · index 25% |
| Non-ducted, 2 tons | 6 · index 47% | 2 · index 41% |
| Non-ducted, 2.5–3 tons | 6 · index 61% | 6 · index 54% |
| Non-ducted, 3.5–4.5 tons | 1 · index 45% | 5 · index 46% |
| Non-ducted, 5 tons and up | None | 2 · index 46% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | FriedrichCold-climate score, best model | YorkCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.9(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A4 of 20 models qualify · AHRI 205048198 | 59.7(50 is the typical model of its size class) (higher)THF2B18S21with ducted air handler AE(D,N,U)+CM24D24+TDR7 of 8 models qualify · AHRI 214606310 |
| Ducted, 2 tons | 74.7(50 is the typical model of its size class) (higher)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU5 of 17 models qualify · AHRI 213829710 | 60.6(50 is the typical model of its size class)THE2B24T21with ducted air handler AX242BTA10 of 16 models qualify · AHRI 211634285 |
| Ducted, 2.5–3 tons | 80.6(50 is the typical model of its size class)FRP18AZ36AJVCwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU5 of 22 models qualify · AHRI 213829722 | 83.8(50 is the typical model of its size class) (higher)HMH72B341with indoor coil CM36B36+TDR and furnace TM9V120D20MP1222 of 53 models qualify · AHRI 211628039 |
| Ducted, 3.5–4.5 tons | 76.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M47 of 28 models qualify · AHRI 214279028 | 77.7(50 is the typical model of its size class) (higher)RHP15048B21with ducted air handler L(E,G)M60A4Also sold as Champion Heating and Cooling THF2B48T2124 of 72 models qualify · AHRI 213612208 |
| Ducted, 5 tons and up | None on this board (0 of 7 models qualify) | 70.2(50 is the typical model of its size class)YMKE60BNJMFMO-X1 of 19 models qualify · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 78.4(50 is the typical model of its size class) (higher)FPHFR09A3Awith ductless indoor unit FPHFC09A3B18 of 19 models qualify · AHRI 205048197 | 64.2(50 is the typical model of its size class)DHS18CMB22S5 of 9 models qualify · AHRI 207616532 |
| Non-ducted, 2 tons | 72.0(50 is the typical model of its size class) (higher)FPHFR24A3Awith ductless indoor unit FPHFC24A3B5 of 6 models qualify · AHRI 205123805 | 66.1(50 is the typical model of its size class)DHS24CMB22S1 of 2 models qualify · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 77.2(50 is the typical model of its size class) (higher)FPHFR36A3Awith ductless indoor unit FPHSC36A3B2 of 6 models qualify · AHRI 205150421 | 60.8(50 is the typical model of its size class)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models qualify · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 41.9(50 is the typical model of its size class) (higher)FPHMR42A3A1 of 1 models qualify · AHRI 205141513 | 31.6(50 is the typical model of its size class)DHS42CMB22S1 of 5 models qualify · AHRI 207616540 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | FriedrichAll-around score, best model | YorkAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 57.7(50 is the typical model of its size class) (higher)FPHFR09A3Awith ducted air handler FPHFD09A3A14 of 20 models have all five ratings · AHRI 205048198 | 57.1(50 is the typical model of its size class)YH2F18SB21with ducted air handler AE*S+CM24C24+TDR7 of 7 models have all five ratings · AHRI 216437405 |
| Ducted, 2 tons | 83.5(50 is the typical model of its size class) (higher)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU12 of 17 models have all five ratings · AHRI 213829710 | 77.1(50 is the typical model of its size class)YMSJYH024BAAND-1with ducted air handler YMSJXH024BAAN--517 of 17 models have all five ratings · AHRI 217734524 |
| Ducted, 2.5–3 tons | 86.1(50 is the typical model of its size class) (higher)FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACA12 of 22 models have all five ratings · AHRI 213087287 | 76.1(50 is the typical model of its size class)YMSJYH048BAAND-1with ducted air handler YMSJXH048BAAN--534 of 51 models have all five ratings · AHRI 217734526 |
| Ducted, 3.5–4.5 tons | 80.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH17 of 27 models have all five ratings · AHRI 214610153 | 83.7(50 is the typical model of its size class) (higher)YZV48B21with indoor coil XAMC48HE3N1+CC and furnace TM9V100C16MP1248 of 73 models have all five ratings · AHRI 211207031 |
| Ducted, 5 tons and up | 70.1(50 is the typical model of its size class)FWP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace FR97MV1005A21DH1 of 8 models have all five ratings · AHRI 213841738 | 75.1(50 is the typical model of its size class) (higher)YMKE60BNJMFMO-X12 of 20 models have all five ratings · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 85.1(50 is the typical model of its size class) (higher)MRH09Y3JAwith ductless indoor unit MWH09Y3JA19 of 19 models have all five ratings · AHRI 201763897 | 50.6(50 is the typical model of its size class)DHS18CMB22S9 of 9 models have all five ratings · AHRI 207616532 |
| Non-ducted, 2 tons | 67.5(50 is the typical model of its size class) (higher)FPHMR24A3A6 of 6 models have all five ratings · AHRI 204101246 | 55.4(50 is the typical model of its size class)DHS24CMB22S2 of 2 models have all five ratings · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 69.4(50 is the typical model of its size class)FPHMR36A3A2 of 6 models have all five ratings · AHRI 204101247 | 74.6(50 is the typical model of its size class) (higher)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models have all five ratings · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 44.5(50 is the typical model of its size class)FPHMR42A3A1 of 1 models have all five ratings · AHRI 205141512 | 67.0(50 is the typical model of its size class) (higher)YVAHP048B21S*Also sold as Coleman CVAHP048B21S3 of 5 models have all five ratings · AHRI 203994968 |
| Non-ducted, 5 tons and up | No models in this size class | 68.5(50 is the typical model of its size class)YVAHP060B21S*2 of 2 models have all five ratings · AHRI 203994964 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Friedrich | York |
|---|---|---|
| COP at 5°F | beats 97% · 2.80WFPU17Z243CDucted, up to 1.5 tons | beats 100% · 3.44THE2B42T21Ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 100% · 105%FRP18AZ48AJVCDucted, 3.5–4.5 tons | beats 100% · 149%THE2B18S21Ducted, up to 1.5 tons |
| HSPF2 | beats 83% · 9.5FPHFR36A3ADucted, 2.5–3 tons | beats 98% · 10.0YVAHP048B21S*Also sold as Coleman CVAHP048B21SDucted, 3.5–4.5 tons |
| SEER2 | beats 96% · 27.5MRH09Y3JANon-ducted, up to 1.5 tons | beats 96% · 18.0YMKE60BNJMFMO-XDucted, 5 tons and up |
| EER2 | beats 93% · 15.5MRH09Y3JANon-ducted, up to 1.5 tons | beats 100% · 16.7YVAHP048B21S*Also sold as Coleman CVAHP048B21SNon-ducted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 100% · 43,500 Btu/hFRP18AZ36AJVCDucted, 2.5–3 tons | beats 99% · 21,800 Btu/hDHS18CMB22SNon-ducted, up to 1.5 tons |