Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
GCHV vs MSH LEGACY heat pumps
Measured against models of the same size and duct type, GCHV and MSH LEGACY split the 6 ratings 3–3. GCHV has 18 outdoor models, MSH LEGACY has 18 outdoor models. GCHV and MSH LEGACY have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- GCHV
- MSH LEGACY
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | GCHV | MSH LEGACY |
|---|---|---|
| Efficiency index | 54% (higher)median — | 51% (higher)median — |
| COP at 5°F | 44%median 1.85 | 78%median 2.22 |
| Capacity retention at 5°F | 65% (higher)median 76% | 16% (higher)median 47% |
| HSPF2 | 32%median 7.6 | 33%median 7.5 |
| SEER2 | 48% (higher)median 16.0 | 29% (higher)median 15.0 |
| EER2 | 49%median 11.4 | 91%median 12.5 |
| Heating capacity at 5°F | 45% (higher)median 21,600 Btu/h | 17% (higher)median 16,600 Btu/h |
| Outdoor models | 18 | 18 |
| AHRI certifications | 34 | 1,716 |
Share of models meeting each standard
| Standard | GCHV | MSH LEGACY |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 5.6%1 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- GCHV
- MSH LEGACY
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | GCHV | MSH LEGACY |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index — | 2 · index 41% |
| Ducted, 2 tons | 4 · index — | 2 · index 53% |
| Ducted, 2.5–3 tons | 6 · index 54% | 4 · index 51% |
| Ducted, 3.5–4.5 tons | 7 · index — | 6 · index 54% |
| Ducted, 5 tons and up | None | 4 · index 54% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | GCHVCold-climate score, best model | MSH LEGACYCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | None on this board (0 of 4 models qualify) | None on this board (0 of 2 models qualify) |
| Ducted, 2.5–3 tons | 48.2(50 is the typical model of its size class)COU-D30HNR1-D01-J0with ducted air handler CAHI-36HNVR1-181 of 6 models qualify · AHRI 207743797 | None on this board (0 of 4 models qualify) |
| Ducted, 3.5–4.5 tons | None on this board (0 of 7 models qualify) | None on this board (0 of 6 models qualify) |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 4 models qualify) |
All-around best
| Size and duct type | GCHVAll-around score, best model | MSH LEGACYAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models have all five ratings) | 41.0(50 is the typical model of its size class)N4H5S18*K*AAA*with indoor coil EA*4X25L17A and furnace *80ESU0401712AAlso listed as R4H5S18*K*AAA2 of 2 models have all five ratings · AHRI 210300397 |
| Ducted, 2 tons | None on this board (0 of 4 models have all five ratings) | 52.7(50 is the typical model of its size class)N4H5S24*K*AAA*with ducted air handler FMA4X30**ALAlso listed as R4H5S24*K*AAA2 of 2 models have all five ratings · AHRI 210099429 |
| Ducted, 2.5–3 tons | 54.4(50 is the typical model of its size class)COU-D30HNR1-D01-J0with ducted air handler CAHI-36HNVR1-181 of 6 models have all five ratings · AHRI 207743797 | 56.1(50 is the typical model of its size class) (higher)N4H5S30*K*AAA*with ducted air handler FMA4X30**ALAlso listed as R4H5S30*K*AAA4 of 4 models have all five ratings · AHRI 209692125 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 7 models have all five ratings) | 60.7(50 is the typical model of its size class)N4H5S42*K*AAA*with ducted air handler FXM4X48**ALAlso listed as R4H5S42*K*AAA4 of 6 models have all five ratings · AHRI 209693273 |
| Ducted, 5 tons and up | No models in this size class | 54.0(50 is the typical model of its size class)N4H5S60*K*AAA*with ducted air handler FJMA4*60L*DAlso listed as R4H5S60*K*AAA2 of 4 models have all five ratings · AHRI 210998915 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | GCHV | MSH LEGACY |
|---|---|---|
| COP at 5°F | beats 44% · 1.85COU-D30HNR1-D01-J0Ducted, 2.5–3 tons | beats 83% · 2.28N4H5S42*K*AAA*Also listed as R4H5S42*K*AAADucted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 62% · 76%COU-D30HNR1-D01-J0Ducted, 2.5–3 tons | beats 36% · 50%N4H5S60*K*AAA*Also listed as R4H5S60*K*AAADucted, 5 tons and up |
| HSPF2 | beats 55% · 8.2COT-60HNVR1-18Ducted, 3.5–4.5 tons | beats 40% · 8.1N4H5S30*K*AAA*Also listed as R4H5S30*K*AAADucted, 2.5–3 tons |
| SEER2 | beats 74% · 16.7CRB-DD48HNR1-WKB2-H0Ducted, 3.5–4.5 tons | beats 40% · 15.2N4H5S42*K*AAA*Also listed as R4H5S42*K*AAADucted, 3.5–4.5 tons |
| EER2 | beats 76% · 12.2COT-24HNVR1-18Ducted, 2 tons | beats 92% · 12.5N4H5S42*K*AAA*Also listed as R4H5S42*K*AAADucted, 3.5–4.5 tons |
| Heating capacity at 5°F | beats 45% · 22,400 Btu/hCOU-D30HNR1-D01-J0Ducted, 2.5–3 tons | beats 31% · 28,400 Btu/hN4H5S60*K*AAA*Also listed as R4H5S60*K*AAADucted, 5 tons and up |