Skip to content

GE Appliances vs MRCOOL heat pumps

Measured against models of the same size and duct type, MRCOOL scores higher on 4 of the 6 ratings. GE Appliances has 66 outdoor models, MRCOOL has 111 outdoor models. They share hardware: 3 equipment families appear under both names.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
GE Appliances and MRCOOL on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, MRCOOL scores higher on 4 of the 6 ratings.
  • GE Appliances
  • MRCOOL
  • Other ranked manufacturers
GE Appli…MRCOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingGE AppliancesMRCOOL
Efficiency index49%median — · 22nd ranked54%median — · 15th ranked
COP at 5°F42%median 1.89 · 24th ranked49%median 1.94 · 18th ranked
Capacity retention at 5°F45% (higher)median 69% · 21st ranked41% (higher)median 64% · 24th ranked
HSPF250%median 9.0 · 16th ranked51%median 8.6 · 15th ranked
SEER246%median 18.0 · 18th ranked50%median 16.6 · 12th ranked
EER250%median 11.7 · 15th ranked56%median 11.7 · 12th ranked
Heating capacity at 5°F47% (higher)median 16,500 Btu/h · 19th ranked43% (higher)median 17,800 Btu/h · 21st ranked
Outdoor models66111
AHRI certifications6,840361

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardGE AppliancesMRCOOL
CEE 2025 Tier 1 (Split ASHP)62.1%41 models46.8%52 models
CEE 2026 Tier 1 (Split ASHP)60.6%40 models43.2%48 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)36.4%24 models25.2%28 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate27.3%18 models22.5%25 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • GE Appliances
  • MRCOOL
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeGE AppliancesMRCOOL
Ducted, up to 1.5 tons9 · index 42%8 · index 55%
Ducted, 2 tons10 · index 51%13 · index 57%
Ducted, 2.5–3 tons9 · index 53%24 · index 55%
Ducted, 3.5–4.5 tons15 · index 54%27 · index 55%
Ducted, 5 tons and upNone4 · index 41%
Non-ducted, up to 1.5 tons24 · index 53%23 · index 56%
Non-ducted, 2 tons8 · index 44%7 · index 56%
Non-ducted, 2.5–3 tons4 · index 35%10 · index 45%
Non-ducted, 3.5–4.5 tons2 · index 18%2 · index 49%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeGE AppliancesCold-climate score, best modelMRCOOLCold-climate score, best model
Ducted, up to 1.5 tons52.9(50 is the typical model of its size class)ASH220NCDD**4 of 9 models qualify · AHRI 21015419073.5(50 is the typical model of its size class) (higher)DIYH-18-HP-C-230C25with ducted air handler DIYH-18-HP-MUAH-230C252 of 8 models qualify · AHRI 210295926
Ducted, 2 tons67.5(50 is the typical model of its size class)NS22H24MA4-**Awith ducted air handler NAM30V2TA44 of 10 models qualify · AHRI 21239641269.5(50 is the typical model of its size class) (higher)CENTRAL-24-HP-C-230A00with ducted air handler CENTRAL-24-HP-MUAH230A005 of 11 models qualify · AHRI 211497151
Ducted, 2.5–3 tons62.0(50 is the typical model of its size class)ASH436NCDD**2 of 9 models qualify · AHRI 21015419774.8(50 is the typical model of its size class) (higher)CENTRAL-36-HP-C-230A00with ducted air handler CENTRAL-36-HP-MUAH230A006 of 26 models qualify · AHRI 210279122
Ducted, 3.5–4.5 tons78.1(50 is the typical model of its size class) (higher)NS17H48SA4-**Awith indoor coil D(A,C,E)48D44+TDR and furnace NF97D070M3B-3 of 15 models qualify · AHRI 21388487477.1(50 is the typical model of its size class)CENTRAL-60-HP-C-230A00with ducted air handler CENTRAL-60-HP-MUAH230A006 of 27 models qualify · AHRI 210279124
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 4 models qualify)
Non-ducted, up to 1.5 tons79.5(50 is the typical model of its size class)ASH112URDE**with ductless indoor unit ASYW12URDE12 of 24 models qualify · AHRI 21240945786.0(50 is the typical model of its size class) (higher)O-ES-09-HP-C-230Bwith ductless indoor unit O-09-HP-WMAH-230B8 of 23 models qualify · AHRI 208552810
Non-ducted, 2 tons61.1(50 is the typical model of its size class)ASH324NCDD**5 of 8 models qualify · AHRI 21015419284.5(50 is the typical model of its size class) (higher)O-HH-24-HP-C-230Awith ductless indoor unit O-24-HP-WMAH-230BAlso listed as O-HH-24-HP-C-230B3 of 7 models qualify · AHRI 207339164
Non-ducted, 2.5–3 tons67.0(50 is the typical model of its size class) (higher)ASH436NCDD**3 of 4 models qualify · AHRI 21015419653.7(50 is the typical model of its size class)DIY-MULTI3-27HP230C1 of 10 models qualify · AHRI 207339195
Non-ducted, 3.5–4.5 tons19.2(50 is the typical model of its size class)ASH4248UCDD**with ductless indoor unit USYL42UCDD1 of 2 models qualify · AHRI 211744614None on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeGE AppliancesAll-around score, best modelMRCOOLAll-around score, best model
Ducted, up to 1.5 tons61.2(50 is the typical model of its size class) (higher)NS17H18SA4-**Awith indoor coil D(A,C,E)24D34+TDR and furnace NF97D070M3B-7 of 9 models have all five ratings · AHRI 21388433259.4(50 is the typical model of its size class)MULTI2-18HP230B4 of 8 models have all five ratings · AHRI 208552830
Ducted, 2 tons82.7(50 is the typical model of its size class) (higher)NS22H24MA4-**Awith ducted air handler NAM30V2TA49 of 10 models have all five ratings · AHRI 21239641268.2(50 is the typical model of its size class)DIYH-24-HP-C-230C25with ducted air handler DIYH-24-HP-MUAH-230C2510 of 13 models have all five ratings · AHRI 210288098
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class) (higher)NS22H36MA4-**Awith indoor coil D(A,C,E)36D44+TDR and furnace NF97D070M3B-7 of 9 models have all five ratings · AHRI 21388468275.4(50 is the typical model of its size class)MULTI3-27HP230B14 of 24 models have all five ratings · AHRI 208552953
Ducted, 3.5–4.5 tons78.0(50 is the typical model of its size class) (higher)NS17H48SA4-**Awith indoor coil D(A,C,E)48D44+TDR and furnace NF80D110S5C-11 of 14 models have all five ratings · AHRI 21388484669.0(50 is the typical model of its size class)MHP17048A-**Awith indoor coil MCHP51CNPA*+TDR+TXV and furnace MGM80SE090C5A16 of 27 models have all five ratings · AHRI 211737253
Ducted, 5 tons and up67.6(50 is the typical model of its size class) (higher)NS17H60SA4-**Awith indoor coil NCUC60CT5D-**+TDR and furnace NF80U110T5C1 of 1 models have all five ratings · AHRI 21749008562.6(50 is the typical model of its size class)MHP17060A-**Awith indoor coil MCVP60CNPA+TDR and furnace MGM80SE090C5A2 of 4 models have all five ratings · AHRI 212619860
Non-ducted, up to 1.5 tons88.8(50 is the typical model of its size class) (higher)ASH109URDE**with ductless indoor unit ASYW09URDE22 of 24 models have all five ratings · AHRI 21240945688.4(50 is the typical model of its size class)O-ES-09-HP-C-230Bwith ductless indoor unit O-09-HP-WMAH-230B23 of 23 models have all five ratings · AHRI 208552810
Non-ducted, 2 tons59.8(50 is the typical model of its size class)ASH324JCDD**8 of 8 models have all five ratings · AHRI 20769899984.3(50 is the typical model of its size class) (higher)O-HH-24-HP-C-230Awith ductless indoor unit O-24-HP-WMAH-230BAlso listed as O-HH-24-HP-C-230B7 of 7 models have all five ratings · AHRI 207339164
Non-ducted, 2.5–3 tons48.7(50 is the typical model of its size class)ASH436NCDD**4 of 4 models have all five ratings · AHRI 21015419678.2(50 is the typical model of its size class) (higher)MULTI3-27HP230B7 of 10 models have all five ratings · AHRI 208552834
Non-ducted, 3.5–4.5 tons18.3(50 is the typical model of its size class)ASH542JCDD**2 of 2 models have all five ratings · AHRI 21053284656.1(50 is the typical model of its size class) (higher)MULTI5-48HP230B2 of 2 models have all five ratings · AHRI 208552838

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingGE AppliancesMRCOOL
COP at 5°Fbeats 99% · 2.99NS17H48SA4-**ADucted, 3.5–4.5 tonsbeats 97% · 2.39O-ES-12-HP-C-230BNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 92% · 106%ASH109URDE**Non-ducted, up to 1.5 tonsbeats 97% · 98%MDPH180484Ducted, 3.5–4.5 tons
HSPF2beats 99% · 14.0ASH109URDSE*Non-ducted, up to 1.5 tonsbeats 98% · 9.8DIY-MULTI5-48HP230CDucted, 3.5–4.5 tons
SEER2beats 100% · 30.0ASH109URDSE*Non-ducted, up to 1.5 tonsbeats 99% · 24.6MULTI3-27HP230BNon-ducted, 2.5–3 tons
EER2beats 100% · 14.5NS17H18SA4-**ADucted, up to 1.5 tonsbeats 99% · 14.0MHP17024A-**ADucted, 2 tons
Heating capacity at 5°Fbeats 94% · 18,500 Btu/hASH220NCDD**Non-ducted, up to 1.5 tonsbeats 99% · 54,356 Btu/hCENTRAL-60-HP-C-230A00Ducted, 3.5–4.5 tons

More comparisons