Skip to content

HEMA vs TUTTO KOOL heat pumps

Measured against models of the same size and duct type, HEMA scores higher on 4 of the 6 ratings. HEMA has 9 outdoor models, TUTTO KOOL has 9 outdoor models. HEMA and TUTTO KOOL have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
HEMA and TUTTO KOOL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, HEMA scores higher on 4 of the 6 ratings.
  • HEMA
  • TUTTO KOOL
  • Other ranked manufacturers
HEMATUTTO KO…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHEMATUTTO KOOL
Efficiency index45% (higher)median —23% (higher)median —
COP at 5°F26%median 1.8026%median 1.80
Capacity retention at 5°F39% (higher)median 67%28% (higher)median 61%
HSPF237% (higher)median 8.511% (higher)median 7.8
SEER255% (higher)median 19.024% (higher)median 19.0
EER241% (higher)median 10.813% (higher)median 9.0
Heating capacity at 5°F39%median 11,900 Btu/h40%median 11,600 Btu/h
Outdoor models99
AHRI certifications99

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHEMATUTTO KOOL
CEE 2025 Tier 1 (Split ASHP)44.4%4 models33.3%3 models
CEE 2026 Tier 1 (Split ASHP)44.4%4 models22.2%2 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)22.2%2 models22.2%2 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • HEMA
  • TUTTO KOOL
  • All models of the group
Ducted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHEMATUTTO KOOL
Ducted, 2.5 to 3 tons1 · index —None
Ducted, 3.5 to 4.5 tons2 · index —None
Non-ducted, up to 1.5 tons3 · index 50%5 · index 22%
Non-ducted, 2 tons1 · index 48%2 · index 26%
Non-ducted, 2.5 to 3 tons2 · index 25%2 · index 25%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHEMACold-climate score, best modelTUTTO KOOLCold-climate score, best model
Ducted, 2.5 to 3 tonsNone on this board (0 of 1 models qualify)No models in this size class
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tons42.0(50 is the typical model of its size class) (higher)DS-2MS0912HC230with ductless indoor unit DS-2MS0912HE2302 of 3 models qualify · AHRI 21480206530.5(50 is the typical model of its size class)TK1912E5CA-Owith ductless indoor unit TK1912E5CA-IAlso listed as TK1912E5CD-O2 of 5 models qualify · AHRI 213244555
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHEMAAll-around score, best modelTUTTO KOOLAll-around score, best model
Ducted, 2.5 to 3 tonsNone on this board (0 of 1 models have all five ratings)No models in this size class
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models have all five ratings)No models in this size class
Non-ducted, up to 1.5 tons52.5(50 is the typical model of its size class) (higher)DS-2MS0912HC230with ductless indoor unit DS-2MS0912HE2303 of 3 models have all five ratings · AHRI 21480206524.8(50 is the typical model of its size class)TK1912E5CA-Owith ductless indoor unit TK1912E5CA-IAlso listed as TK1912E5CD-O3 of 5 models have all five ratings · AHRI 213244555
Non-ducted, 2 tons48.0(50 is the typical model of its size class) (higher)DS-2MS2422HC200with ductless indoor unit DS-2MS2422HE2001 of 1 models have all five ratings · AHRI 21480206826.1(50 is the typical model of its size class)TK1924E5CD-Owith ductless indoor unit TK1924E5CD-I1 of 2 models have all five ratings · AHRI 213244557
Non-ducted, 2.5 to 3 tons24.9(50 is the typical model of its size class)DS-2MS3621HC190with ductless indoor unit DS-2MS3621HE1901 of 2 models have all five ratings · AHRI 21480206324.9(50 is the typical model of its size class)TK1936E5CD-Owith ductless indoor unit TK1936E5CD-I1 of 2 models have all five ratings · AHRI 213244558

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHEMATUTTO KOOL
COP at 5°Fbeats 31% · 1.80DS-2MS2422HC200Non-ducted, 2 tonsbeats 31% · 1.80TK1924E5CD-ONon-ducted, 2 tons
Capacity retention at 5°Fbeats 58% · 74%DS-2MS0912HC230Non-ducted, up to 1.5 tonsbeats 48% · 70%TK1912E5CA-OAlso listed as TK1912E5CD-ONon-ducted, up to 1.5 tons
HSPF2beats 50% · 8.1DS-48SDC-18Ducted, 3.5 to 4.5 tonsbeats 26% · 8.5TK1936E5CD-ONon-ducted, 2.5 to 3 tons
SEER2beats 73% · 23.0DS-2MS0912HC230Non-ducted, up to 1.5 tonsbeats 36% · 19.0TK1924E5CD-ONon-ducted, 2 tons
EER2beats 68% · 13.0DS-2MS1822HC220Non-ducted, up to 1.5 tonsbeats 24% · 10.0TK1924E5CD-ONon-ducted, 2 tons
Heating capacity at 5°Fbeats 67% · 11,900 Btu/hDS-2MS1822HC220Non-ducted, up to 1.5 tonsbeats 62% · 11,600 Btu/hTK1918W5CD-ONon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter