Measured against models of the same size and duct type, Senville scores higher on 5 of the 6 ratings. HITACHI has 27 outdoor models, Senville has 27 outdoor models. HITACHI has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
HITACHI and Senville on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Senville scores higher on 5 of the 6 ratings.
  • HITACHI
  • Senville
  • Other ranked manufacturers
HITACHISenville

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHITACHISenville
Efficiency index58%median —61%median — · 7th ranked
COP at 5°F72% (higher)median 2.2544% (higher)median 1.91 · 22nd ranked
Capacity retention at 5°F57%median 76%60%median 82% · 7th ranked
HSPF265%median 9.867%median 9.5 · 6th ranked
SEER250%median 20.067%median 21.4 · 3rd ranked
EER253%median 12.556%median 11.7 · 11th ranked
Heating capacity at 5°F49%median 14,500 Btu/h58%median 20,000 Btu/h · 7th ranked
Outdoor models2727
AHRI certifications4759

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHITACHISenville
CEE 2025 Tier 1 (Split ASHP)74.1%20 models70.4%19 models
CEE 2026 Tier 1 (Split ASHP)74.1%20 models63%17 models
CEE Advanced Tier (Split ASHP)0%0 models3.7%1 models
Xcel Energy Colorado cold-climate ASHP (2025)66.7%18 models44.4%12 models
DOE Cold Climate Heat Pump Challenge0%0 models3.7%1 models
ENERGY STAR Cold Climate14.8%4 models51.9%14 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • HITACHI
  • Senville
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsNon-ducted, 5 tons and up2.1032 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHITACHISenville
Ducted, up to 1.5 tons4 · index 50%5 · index 63%
Ducted, 2 tons2 · index 56%2 · index 73%
Ducted, 2.5–3 tons3 · index 71%5 · index 69%
Ducted, 3.5–4.5 tons3 · index 66%4 · index 63%
Non-ducted, up to 1.5 tons15 · index 57%10 · index 54%
Non-ducted, 2 tons5 · index 57%2 · index 50%
Non-ducted, 2.5–3 tons4 · index 52%9 · index 60%
Non-ducted, 3.5–4.5 tons2 · index 60%2 · index 67%
Non-ducted, 5 tons and up1 · index 69%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHITACHICold-climate score, best modelSenvilleCold-climate score, best model
Ducted, up to 1.5 tons55.9(50 is the typical model of its size class)RAS-1.0PNNBDH1with ducted air handler RPIL-1.0PNN1DH2 of 4 models qualify · AHRI 20675085274.9(50 is the typical model of its size class) (higher)SENA/09HF/OQwith ducted air handler SENA/09HF/ID5 of 5 models qualify · AHRI 207641345
Ducted, 2 tons64.8(50 is the typical model of its size class)RAS-3.0PNNBDH1with ducted air handler RPIM-3.0PNN1DH1 of 2 models qualify · AHRI 20675085879.4(50 is the typical model of its size class) (higher)SENA/24HF/OQwith ducted air handler SENA/24HF/ID2 of 2 models qualify · AHRI 207641348
Ducted, 2.5–3 tons78.1(50 is the typical model of its size class)RAS-4.0PNNBDH1with ducted air handler RPIM-4.0PNN1DH2 of 3 models qualify · AHRI 20675086079.9(50 is the typical model of its size class) (higher)SENA-36HF-MOB3 of 5 models qualify · AHRI 213732657
Ducted, 3.5–4.5 tonsNone on this board (0 of 3 models qualify)74.9(50 is the typical model of its size class)SENA-48HF-MOB3 of 4 models qualify · AHRI 213732660
Non-ducted, up to 1.5 tons81.1(50 is the typical model of its size class) (higher)RAC-SH09WHLAEwith ductless indoor unit RAS-SH09RHLAE13 of 15 models qualify · AHRI 20690717277.5(50 is the typical model of its size class)SENA/12HF/OQwith ductless indoor unit SENA/12HF/IQ4 of 10 models qualify · AHRI 207571419
Non-ducted, 2 tons76.3(50 is the typical model of its size class)RAC-PH24WHLAEwith ductless indoor unit RAS-PH24PHLAE3 of 5 models qualify · AHRI 20720048386.1(50 is the typical model of its size class) (higher)SENA/24HF/OQwith ductless indoor unit SENA/24HF/ICQ1 of 2 models qualify · AHRI 207641344
Non-ducted, 2.5–3 tons77.2(50 is the typical model of its size class)RAS-4.0PNNBDH1with ductless indoor unit RCI-4.0PNN1DH3 of 4 models qualify · AHRI 20675085990.9(50 is the typical model of its size class) (higher)SENA-36HF-MOB3 of 9 models qualify · AHRI 213732656
Non-ducted, 3.5–4.5 tonsNone on this board (0 of 2 models qualify)76.2(50 is the typical model of its size class)SENA-48HF-MOB1 of 2 models qualify · AHRI 213732659
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHITACHIAll-around score, best modelSenvilleAll-around score, best model
Ducted, up to 1.5 tons57.7(50 is the typical model of its size class)RAS-1.0PNNBDH1with ducted air handler RPIL-1.0PNN1DH3 of 4 models have all five ratings · AHRI 20675085285.2(50 is the typical model of its size class) (higher)SENA/09HF/OQwith ducted air handler SENA/09HF/ID5 of 5 models have all five ratings · AHRI 207641345
Ducted, 2 tons55.8(50 is the typical model of its size class)RAS-3.0PNNBDH1with ducted air handler RPIM-3.0PNN1DH1 of 2 models have all five ratings · AHRI 20675085880.1(50 is the typical model of its size class) (higher)SENA/24HF/OQwith ducted air handler SENA/24HF/ID2 of 2 models have all five ratings · AHRI 207641348
Ducted, 2.5–3 tons74.3(50 is the typical model of its size class)HVAHP036B21S*2 of 3 models have all five ratings · AHRI 20399497583.7(50 is the typical model of its size class) (higher)SENA-36HF-MOB5 of 5 models have all five ratings · AHRI 213732657
Ducted, 3.5–4.5 tons77.8(50 is the typical model of its size class)HVAHP048B21S*2 of 3 models have all five ratings · AHRI 20399497682.0(50 is the typical model of its size class) (higher)SENA-48HF-MOB4 of 4 models have all five ratings · AHRI 213732660
Non-ducted, up to 1.5 tons72.1(50 is the typical model of its size class)RAC-SH09WHLAEwith ductless indoor unit RAS-SH09RHLAE14 of 15 models have all five ratings · AHRI 20690717287.6(50 is the typical model of its size class) (higher)SENA/09HF/OQwith ductless indoor unit SENA/09HF/IQ10 of 10 models have all five ratings · AHRI 207571418
Non-ducted, 2 tons73.1(50 is the typical model of its size class)RAC-PH24WHLAEwith ductless indoor unit RAS-PH24PHLAE4 of 5 models have all five ratings · AHRI 20720048384.3(50 is the typical model of its size class) (higher)SENA/24HF/OQwith ductless indoor unit SENA/24HF/IQ2 of 2 models have all five ratings · AHRI 207657630
Non-ducted, 2.5–3 tons74.6(50 is the typical model of its size class)HVAHP036B21S*3 of 4 models have all five ratings · AHRI 20399496986.4(50 is the typical model of its size class) (higher)SENA-36HF-MOB7 of 9 models have all five ratings · AHRI 213732656
Non-ducted, 3.5–4.5 tons67.0(50 is the typical model of its size class)HVAHP048B21S*1 of 2 models have all five ratings · AHRI 20399497077.9(50 is the typical model of its size class) (higher)SENA-48HF-MOB2 of 2 models have all five ratings · AHRI 213732659
Non-ducted, 5 tons and up68.5(50 is the typical model of its size class)HVAHP060B21S*1 of 1 models have all five ratings · AHRI 203994965No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHITACHISenville
COP at 5°Fbeats 99% · 2.30RAC-EH24WHLAENon-ducted, 2 tonsbeats 91% · 2.21SENA/24HF/OQNon-ducted, 2 tons
Capacity retention at 5°Fbeats 99% · 133%RAC-PH09WHLAENon-ducted, up to 1.5 tonsbeats 97% · 103%SENA-36HF-MOBNon-ducted, 2.5–3 tons
HSPF2beats 98% · 10.0HVAHP048B21S*Ducted, 3.5–4.5 tonsbeats 98% · 12.0SENA/09HF/OQDucted, up to 1.5 tons
SEER2beats 93% · 23.1HVAHP048B21S*Non-ducted, 3.5–4.5 tonsbeats 99% · 24.6SENA/30HF/MOQNon-ducted, 2.5–3 tons
EER2beats 100% · 16.7HVAHP048B21S*Non-ducted, 3.5–4.5 tonsbeats 98% · 16.2SENA/09HF/OQNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 23,000 Btu/hRAC-PH18WHLAENon-ducted, up to 1.5 tonsbeats 96% · 20,000 Btu/hSENA-18HF-MOBNon-ducted, up to 1.5 tons

More comparisons