Both views use the same certified data. This device remembers your choice.
iFLOW vs WINDAIR heat pumps
Measured against models of the same size and duct type, iFLOW scores higher on 5 of the 6 ratings. iFLOW has 14 outdoor models, WINDAIR has 15 outdoor models. iFLOW and WINDAIR have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- iFLOW
- WINDAIR
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | iFLOW | WINDAIR |
|---|---|---|
| Efficiency index | 43% (higher)median — | 32% (higher)median — |
| COP at 5°F | 44% (higher)median 1.88 | 16% (higher)median 1.75 |
| Capacity retention at 5°F | 58% (higher)median 79% | 31% (higher)median 66% |
| HSPF2 | 70% (higher)median 9.1 | 26% (higher)median 8.5 |
| SEER2 | 36% (higher)median 15.2 | 34% (higher)median 18.5 |
| EER2 | 21%median 10.0 | 45%median 10.9 |
| Heating capacity at 5°F | 63% (higher)median 29,000 Btu/h | 30% (higher)median 8,400 Btu/h |
| Outdoor models | 14 | 15 |
| AHRI certifications | 19 | 15 |
Share of models meeting each standard
| Standard | iFLOW | WINDAIR |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 14.3%2 models | 60%9 models |
| CEE 2026 Tier 1 (Split ASHP) | 14.3%2 models | 46.7%7 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 50%7 models | 20%3 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- iFLOW
- WINDAIR
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | iFLOW | WINDAIR |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index 52% | None |
| Ducted, 2 tons | 2 · index 50% | None |
| Ducted, 2.5 to 3 tons | 5 · index 43% | None |
| Ducted, 3.5 to 4.5 tons | 6 · index 39% | None |
| Non-ducted, up to 1.5 tons | None | 12 · index 33% |
| Non-ducted, 2 tons | None | 2 · index 26% |
| Non-ducted, 2.5 to 3 tons | None | 1 · index 30% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | iFLOWCold-climate score, best model | WINDAIRCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 64.2(50 is the typical model of its size class)70HPIC18Awith ducted air handler 70C1824BA1 of 1 models qualify · AHRI 212546248 | No models in this size class |
| Ducted, 2 tons | 67.6(50 is the typical model of its size class)70HPIR24Awith ducted air handler 70C1824BA2 of 2 models qualify · AHRI 217729802 | No models in this size class |
| Ducted, 2.5 to 3 tons | 78.7(50 is the typical model of its size class)70HPIC36Awith ducted air handler 70C3036CA3 of 5 models qualify · AHRI 212546252 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 61.6(50 is the typical model of its size class)70HPIC45Awith ducted air handler 70C5460DA3 of 6 models qualify · AHRI 213279880 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 76.0(50 is the typical model of its size class)DWH09UW3SXETE00/Owith ductless indoor unit DWH09UW3SXETE00/I4 of 12 models qualify · AHRI 202021941 |
| Non-ducted, 2 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Non-ducted, 2.5 to 3 tons | No models in this size class | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | iFLOWAll-around score, best model | WINDAIRAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 51.9(50 is the typical model of its size class)70HPIC18Awith ducted air handler 70C1824BA1 of 1 models have all five ratings · AHRI 212546248 | No models in this size class |
| Ducted, 2 tons | 53.2(50 is the typical model of its size class)70HPIC24Awith ducted air handler 70C1824AA2 of 2 models have all five ratings · AHRI 218029482 | No models in this size class |
| Ducted, 2.5 to 3 tons | 52.9(50 is the typical model of its size class)70HPIC36Awith ducted air handler 70C3036CA5 of 5 models have all five ratings · AHRI 212546252 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 49.9(50 is the typical model of its size class)70HPIC45Awith ducted air handler 70C5460DA6 of 6 models have all five ratings · AHRI 213279880 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 85.6(50 is the typical model of its size class)DWH09UW3SXETE00/Owith ductless indoor unit DWH09UW3SXETE00/I12 of 12 models have all five ratings · AHRI 202021941 |
| Non-ducted, 2 tons | No models in this size class | 40.8(50 is the typical model of its size class)DWH24UR3SDBTE/Owith ductless indoor unit DWH24UR3SDBTE/I2 of 2 models have all five ratings · AHRI 202021940 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 29.7(50 is the typical model of its size class)DWH30UR3SDKVQ/Owith ductless indoor unit DWH30UR3SDKVQ/I1 of 1 models have all five ratings · AHRI 202021947 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | iFLOW | WINDAIR |
|---|---|---|
| COP at 5°F | beats 76% · 2.2070HPIC18ADucted, up to 1.5 tons | beats 79% · 2.10DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 79% · 85%70HPIC45ADucted, 3.5 to 4.5 tons | beats 66% · 78%DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 93% · 10.070HPIC36ADucted, 2.5 to 3 tons | beats 79% · 10.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons |
| SEER2 | beats 47% · 16.570HPIC24ADucted, 2 tons | beats 96% · 27.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons |
| EER2 | beats 36% · 11.770HPIC18ADucted, up to 1.5 tons | beats 93% · 15.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 89% · 46,500 Btu/h70HPIC45ADucted, 3.5 to 4.5 tons | beats 67% · 11,900 Btu/hDWH18UR3SXATE/ONon-ducted, up to 1.5 tons |