Skip to content

iFLOW vs WINDAIR heat pumps

Measured against models of the same size and duct type, iFLOW scores higher on 5 of the 6 ratings. iFLOW has 14 outdoor models, WINDAIR has 15 outdoor models. iFLOW and WINDAIR have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
iFLOW and WINDAIR on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, iFLOW scores higher on 5 of the 6 ratings.
  • iFLOW
  • WINDAIR
  • Other ranked manufacturers
iFLOWWINDAIR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingiFLOWWINDAIR
Efficiency index43% (higher)median —32% (higher)median —
COP at 5°F44% (higher)median 1.8816% (higher)median 1.75
Capacity retention at 5°F58% (higher)median 79%31% (higher)median 66%
HSPF270% (higher)median 9.126% (higher)median 8.5
SEER236% (higher)median 15.234% (higher)median 18.5
EER221%median 10.045%median 10.9
Heating capacity at 5°F63% (higher)median 29,000 Btu/h30% (higher)median 8,400 Btu/h
Outdoor models1415
AHRI certifications1915

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardiFLOWWINDAIR
CEE 2025 Tier 1 (Split ASHP)14.3%2 models60%9 models
CEE 2026 Tier 1 (Split ASHP)14.3%2 models46.7%7 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)50%7 models20%3 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 0 groups where both have models
  • iFLOW
  • WINDAIR
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeiFLOWWINDAIR
Ducted, up to 1.5 tons1 · index 52%None
Ducted, 2 tons2 · index 50%None
Ducted, 2.5 to 3 tons5 · index 43%None
Ducted, 3.5 to 4.5 tons6 · index 39%None
Non-ducted, up to 1.5 tonsNone12 · index 33%
Non-ducted, 2 tonsNone2 · index 26%
Non-ducted, 2.5 to 3 tonsNone1 · index 30%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeiFLOWCold-climate score, best modelWINDAIRCold-climate score, best model
Ducted, up to 1.5 tons64.2(50 is the typical model of its size class)70HPIC18Awith ducted air handler 70C1824BA1 of 1 models qualify · AHRI 212546248No models in this size class
Ducted, 2 tons67.6(50 is the typical model of its size class)70HPIR24Awith ducted air handler 70C1824BA2 of 2 models qualify · AHRI 217729802No models in this size class
Ducted, 2.5 to 3 tons78.7(50 is the typical model of its size class)70HPIC36Awith ducted air handler 70C3036CA3 of 5 models qualify · AHRI 212546252No models in this size class
Ducted, 3.5 to 4.5 tons61.6(50 is the typical model of its size class)70HPIC45Awith ducted air handler 70C5460DA3 of 6 models qualify · AHRI 213279880No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class76.0(50 is the typical model of its size class)DWH09UW3SXETE00/Owith ductless indoor unit DWH09UW3SXETE00/I4 of 12 models qualify · AHRI 202021941
Non-ducted, 2 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, 2.5 to 3 tonsNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeiFLOWAll-around score, best modelWINDAIRAll-around score, best model
Ducted, up to 1.5 tons51.9(50 is the typical model of its size class)70HPIC18Awith ducted air handler 70C1824BA1 of 1 models have all five ratings · AHRI 212546248No models in this size class
Ducted, 2 tons53.2(50 is the typical model of its size class)70HPIC24Awith ducted air handler 70C1824AA2 of 2 models have all five ratings · AHRI 218029482No models in this size class
Ducted, 2.5 to 3 tons52.9(50 is the typical model of its size class)70HPIC36Awith ducted air handler 70C3036CA5 of 5 models have all five ratings · AHRI 212546252No models in this size class
Ducted, 3.5 to 4.5 tons49.9(50 is the typical model of its size class)70HPIC45Awith ducted air handler 70C5460DA6 of 6 models have all five ratings · AHRI 213279880No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class85.6(50 is the typical model of its size class)DWH09UW3SXETE00/Owith ductless indoor unit DWH09UW3SXETE00/I12 of 12 models have all five ratings · AHRI 202021941
Non-ducted, 2 tonsNo models in this size class40.8(50 is the typical model of its size class)DWH24UR3SDBTE/Owith ductless indoor unit DWH24UR3SDBTE/I2 of 2 models have all five ratings · AHRI 202021940
Non-ducted, 2.5 to 3 tonsNo models in this size class29.7(50 is the typical model of its size class)DWH30UR3SDKVQ/Owith ductless indoor unit DWH30UR3SDKVQ/I1 of 1 models have all five ratings · AHRI 202021947

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingiFLOWWINDAIR
COP at 5°Fbeats 76% · 2.2070HPIC18ADucted, up to 1.5 tonsbeats 79% · 2.10DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 79% · 85%70HPIC45ADucted, 3.5 to 4.5 tonsbeats 66% · 78%DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
HSPF2beats 93% · 10.070HPIC36ADucted, 2.5 to 3 tonsbeats 79% · 10.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
SEER2beats 47% · 16.570HPIC24ADucted, 2 tonsbeats 96% · 27.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
EER2beats 36% · 11.770HPIC18ADucted, up to 1.5 tonsbeats 93% · 15.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 89% · 46,500 Btu/h70HPIC45ADucted, 3.5 to 4.5 tonsbeats 67% · 11,900 Btu/hDWH18UR3SXATE/ONon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter