Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Innovair vs Nortek Global HVAC heat pumps
Measured against models of the same size and duct type, Innovair scores higher on 4 of the 6 ratings. Innovair has 44 outdoor models, Nortek Global HVAC has 75 outdoor models. They share hardware: 11 equipment families appear under both names.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Innovair
- Nortek Global HVAC
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Innovair | Nortek Global HVAC |
|---|---|---|
| Efficiency index | 56% (higher)median — · 12th ranked | 51% (higher)median — · 20th ranked |
| COP at 5°F | 51% (higher)median 1.91 · 17th ranked | 44% (higher)median 1.85 · 23rd ranked |
| Capacity retention at 5°F | 64%median 82% · 6th ranked | 64%median 80% · 4th ranked |
| HSPF2 | 53% (higher)median 8.8 · 13th ranked | 38% (higher)median 8.2 · 22nd ranked |
| SEER2 | 50% (higher)median 17.0 · 12th ranked | 39% (higher)median 16.5 · 22nd ranked |
| EER2 | 42%median 10.6 · 25th ranked | 46%median 11.0 · 21st ranked |
| Heating capacity at 5°F | 64% (higher)median 21,555 Btu/h · 4th ranked | 56% (higher)median 14,500 Btu/h · 10th ranked |
| Outdoor models | 44 | 75 |
| AHRI certifications | 91 | 280 |
Share of models meeting each standard
| Standard | Innovair | Nortek Global HVAC |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 52.3%23 models | 38.7%29 models |
| CEE 2026 Tier 1 (Split ASHP) | 47.7%21 models | 38.7%29 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 47.7%21 models | 41.3%31 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 52.3%23 models | 29.3%22 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Innovair
- Nortek Global HVAC
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Innovair | Nortek Global HVAC |
|---|---|---|
| Ducted, up to 1.5 tons | 5 · index 53% | 10 · index 47% |
| Ducted, 2 tons | 5 · index 63% | 7 · index 52% |
| Ducted, 2.5–3 tons | 7 · index 51% | 20 · index 55% |
| Ducted, 3.5–4.5 tons | 6 · index 53% | 13 · index 58% |
| Ducted, 5 tons and up | 1 · index 42% | None |
| Non-ducted, up to 1.5 tons | 11 · index 68% | 23 · index 47% |
| Non-ducted, 2 tons | 5 · index 68% | 7 · index 53% |
| Non-ducted, 2.5–3 tons | 7 · index 44% | 10 · index 56% |
| Non-ducted, 3.5–4.5 tons | 1 · index 45% | 1 · index 45% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | InnovairCold-climate score, best model | Nortek Global HVACCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class) (higher)SHV18H2R20with ducted air handler WEV18H2R194 of 5 models qualify · AHRI 213255597 | 55.9(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models qualify · AHRI 207237540 |
| Ducted, 2 tons | 75.6(50 is the typical model of its size class) (higher)MHD-24with ducted air handler MHD-CC2.0-17.5-M4 of 5 models qualify · AHRI 210365430 | 68.1(50 is the typical model of its size class)WHM24SZA21Swith ducted air handler D(A,C,E)24D44+TDR4 of 6 models qualify · AHRI 214640590 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class) (higher)SHV36H2R20with ducted air handler MAC36H2124E4 of 7 models qualify · AHRI 213160476 | 78.1(50 is the typical model of its size class)WHU36SZA21Swith ducted air handler WHU36DHA21S7 of 21 models qualify · AHRI 207237544 |
| Ducted, 3.5–4.5 tons | 73.8(50 is the typical model of its size class) (higher)SHV48H2R20with ducted air handler DEV48H2R193 of 6 models qualify · AHRI 210343157 | 73.0(50 is the typical model of its size class)WHM60SZA21Swith ducted air handler D(A,C,E)60B44+TDR4 of 13 models qualify · AHRI 214640596 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | 80.1(50 is the typical model of its size class) (higher)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 11 models qualify · AHRI 206330207 | 78.4(50 is the typical model of its size class)WHU09SZA21Swith ductless indoor unit WHU09CTA21S17 of 23 models qualify · AHRI 207237535 |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models qualify · AHRI 206330210 | 76.1(50 is the typical model of its size class) (higher)GXH24(7.0)FMK4DH-15 of 7 models qualify · AHRI 210276801 |
| Non-ducted, 2.5–3 tons | 64.0(50 is the typical model of its size class)VOM36H7R4P71 of 7 models qualify · AHRI 207821954 | 77.2(50 is the typical model of its size class) (higher)WHU36SZA21Swith ductless indoor unit WHU36CTA21S7 of 10 models qualify · AHRI 207237539 |
| Non-ducted, 3.5–4.5 tons | 41.9(50 is the typical model of its size class)VOM42H7R5P71 of 1 models qualify · AHRI 207821958 | 42.0(50 is the typical model of its size class) (higher)WHP42M5A21S1 of 1 models qualify · AHRI 208404161 |
All-around best
| Size and duct type | InnovairAll-around score, best model | Nortek Global HVACAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 82.8(50 is the typical model of its size class) (higher)SHV18H2R20with ducted air handler WEV18H2R195 of 5 models have all five ratings · AHRI 213255597 | 57.7(50 is the typical model of its size class)WHU09SZA21Swith ducted air handler WHU09DHA21S5 of 10 models have all five ratings · AHRI 207237540 |
| Ducted, 2 tons | 71.6(50 is the typical model of its size class)VOM24H7R3P75 of 5 models have all five ratings · AHRI 207821950 | 71.6(50 is the typical model of its size class)WHP24M3A21S6 of 7 models have all five ratings · AHRI 208404156 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class)VOM36H7R4P77 of 7 models have all five ratings · AHRI 207821953 | 78.6(50 is the typical model of its size class)WHP36M4A21S7 of 20 models have all five ratings · AHRI 208404158 |
| Ducted, 3.5–4.5 tons | 60.7(50 is the typical model of its size class)VOM42H7R5P76 of 6 models have all five ratings · AHRI 207821956 | 65.5(50 is the typical model of its size class) (higher)WHM48SZA21Swith ducted air handler DC61A44-245R4 of 13 models have all five ratings · AHRI 213886028 |
| Ducted, 5 tons and up | 41.7(50 is the typical model of its size class)SEV60H2R19with ducted air handler DEV60H2R191 of 1 models have all five ratings · AHRI 208106863 | No models in this size class |
| Non-ducted, up to 1.5 tons | 88.7(50 is the typical model of its size class) (higher)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 11 models have all five ratings · AHRI 206330207 | 85.4(50 is the typical model of its size class)WHZ09SZA21Swith ductless indoor unit WHZ09WMA21S19 of 24 models have all five ratings · AHRI 207337194 |
| Non-ducted, 2 tons | 76.3(50 is the typical model of its size class) (higher)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models have all five ratings · AHRI 206330210 | 71.5(50 is the typical model of its size class)GXH24(7.0)FMK4DH-16 of 7 models have all five ratings · AHRI 210276801 |
| Non-ducted, 2.5–3 tons | 69.5(50 is the typical model of its size class)VOM36H7R4P75 of 7 models have all five ratings · AHRI 207821954 | 70.2(50 is the typical model of its size class) (higher)GXH42(12.3)FMK4DH-18 of 10 models have all five ratings · AHRI 210276799 |
| Non-ducted, 3.5–4.5 tons | 44.5(50 is the typical model of its size class)VOM42H7R5P71 of 1 models have all five ratings · AHRI 207821957 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Innovair | Nortek Global HVAC |
|---|---|---|
| COP at 5°F | beats 91% · 2.37VEA36H2V18Ducted, 2.5–3 tons | beats 96% · 2.28WHU36SZA21SNon-ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 99% · 144%EIN10H2V32(O)Non-ducted, up to 1.5 tons | beats 99% · 113%WHP36M4A21SNon-ducted, 2.5–3 tons |
| HSPF2 | beats 93% · 10.8SHV18H2R20Ducted, up to 1.5 tons | beats 83% · 9.5WHU36SZA21SDucted, 2.5–3 tons |
| SEER2 | beats 96% · 21.0VOM24H7R3P7Ducted, 2 tons | beats 96% · 27.5WHZ09SZA21SNon-ducted, up to 1.5 tons |
| EER2 | beats 99% · 16.6EIN10H2V32(O)Non-ducted, up to 1.5 tons | beats 93% · 15.5WHZ09SZA21SNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 96% · 20,000 Btu/hEIN18H2V32(O)Non-ducted, up to 1.5 tons | beats 92% · 18,000 Btu/hWHP18M2A21SNon-ducted, up to 1.5 tons |