J-KU vs LLOYD heat pumps

Measured against models of the same size and duct type, J-KU scores higher on 6 of the 6 ratings. J-KU has 10 outdoor models, LLOYD has 10 outdoor models. J-KU and LLOYD have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
J-KU and LLOYD on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, J-KU scores higher on 6 of the 6 ratings.
  • J-KU
  • LLOYD
  • Other ranked manufacturers
J-KULLOYD

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingJ-KULLOYD
Efficiency index62% (higher)median —21% (higher)median —
COP at 5°F49% (higher)median 1.8414% (higher)median 1.79
Capacity retention at 5°F66% (higher)median 87%38% (higher)median 70%
HSPF248% (higher)median 9.010% (higher)median 8.2
SEER267% (higher)median 21.524% (higher)median 19.0
EER271% (higher)median 12.814% (higher)median 10.0
Heating capacity at 5°F61% (higher)median 15,015 Btu/h47% (higher)median 10,100 Btu/h
Outdoor models1010
AHRI certifications1010

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardJ-KULLOYD
CEE 2025 Tier 1 (Split ASHP)100%10 models40%4 models
CEE 2026 Tier 1 (Split ASHP)100%10 models40%4 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)90%9 models40%4 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate80%8 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • J-KU
  • LLOYD
  • All models of the group
Non-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeJ-KULLOYD
Non-ducted, up to 1.5 tons6 · index 62%8 · index 19%
Non-ducted, 2 tons2 · index 63%2 · index 28%
Non-ducted, 2.5–3 tons1 · index 70%None
Non-ducted, 3.5–4.5 tons1 · index 45%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeJ-KUCold-climate score, best modelLLOYDCold-climate score, best model
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class) (higher)JKS09HP230V1XCwith ductless indoor unit JKS09HP230V1XE5 of 6 models qualify · AHRI 21158373926.2(50 is the typical model of its size class)GSSHAX7488*with ductless indoor unit GSSHAX74873 of 8 models qualify · AHRI 214731814
Non-ducted, 2 tons64.4(50 is the typical model of its size class) (higher)JKS-24H2HP-M3O2 of 2 models qualify · AHRI 21328675425.4(50 is the typical model of its size class)GSSHAX7496*with ductless indoor unit GSSHAX74951 of 2 models qualify · AHRI 214731818
Non-ducted, 2.5–3 tons64.0(50 is the typical model of its size class)JKS-36H2HP-M4O1 of 1 models qualify · AHRI 213286756No models in this size class
Non-ducted, 3.5–4.5 tons41.8(50 is the typical model of its size class)JKS-42H2HP-M5O1 of 1 models qualify · AHRI 213286755No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeJ-KUAll-around score, best modelLLOYDAll-around score, best model
Non-ducted, up to 1.5 tons89.2(50 is the typical model of its size class) (higher)JKS09HP230V1XCwith ductless indoor unit JKS09HP230V1XE6 of 6 models have all five ratings · AHRI 21158373922.5(50 is the typical model of its size class)GSSHAX7488*with ductless indoor unit GSSHAX74875 of 8 models have all five ratings · AHRI 214731814
Non-ducted, 2 tons71.3(50 is the typical model of its size class) (higher)JKS-24H2HP-M3O2 of 2 models have all five ratings · AHRI 21328675427.9(50 is the typical model of its size class)GSSHAX7496*with ductless indoor unit GSSHAX74951 of 2 models have all five ratings · AHRI 214731818
Non-ducted, 2.5–3 tons69.5(50 is the typical model of its size class)JKS-36H2HP-M4O1 of 1 models have all five ratings · AHRI 213286756No models in this size class
Non-ducted, 3.5–4.5 tons44.5(50 is the typical model of its size class)JKS-42H2HP-M5O1 of 1 models have all five ratings · AHRI 213286755No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingJ-KULLOYD
COP at 5°Fbeats 97% · 2.41JKS12HP230V1XCNon-ducted, up to 1.5 tonsbeats 22% · 1.80GOS18IH219TALWNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 113%JKS-36H2HP-M4ONon-ducted, 2.5–3 tonsbeats 46% · 70%GSSHAX7490*Also listed as GSSHAX7492Non-ducted, up to 1.5 tons
HSPF2beats 79% · 10.5JKS09HP230V1XCNon-ducted, up to 1.5 tonsbeats 21% · 8.5GSSHAX7496*Non-ducted, 2 tons
SEER2beats 96% · 27.5JKS09HP230V1XCNon-ducted, up to 1.5 tonsbeats 35% · 19.0GSSHAX7496*Non-ducted, 2 tons
EER2beats 93% · 15.5JKS09HP230V1XCNon-ducted, up to 1.5 tonsbeats 25% · 10.0GSSHAX7496*Non-ducted, 2 tons
Heating capacity at 5°Fbeats 92% · 18,000 Btu/hJKS-18H2HP-M2ONon-ducted, up to 1.5 tonsbeats 79% · 13,170 Btu/hGSSHAX7494*Non-ducted, up to 1.5 tons