Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
J-KU vs TURBRO heat pumps
Measured against models of the same size and duct type, J-KU scores higher on 5 of the 6 ratings. J-KU has 10 outdoor models, TURBRO has 10 outdoor models. J-KU and TURBRO have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- J-KU
- TURBRO
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | J-KU | TURBRO |
|---|---|---|
| Efficiency index | 62% (higher)median — | 51% (higher)median — |
| COP at 5°F | 49% (higher)median 1.84 | 23% (higher)median 1.80 |
| Capacity retention at 5°F | 66% (higher)median 87% | 42% (higher)median 69% |
| HSPF2 | 48% (higher)median 9.0 | 47% (higher)median 9.0 |
| SEER2 | 67%median 21.5 | 72%median 22.0 |
| EER2 | 71% (higher)median 12.8 | 57% (higher)median 12.5 |
| Heating capacity at 5°F | 61% (higher)median 15,015 Btu/h | 43% (higher)median 12,850 Btu/h |
| Outdoor models | 10 | 10 |
| AHRI certifications | 10 | 10 |
Share of models meeting each standard
| Standard | J-KU | TURBRO |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%10 models | 100%10 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%10 models | 100%10 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 90%9 models | 50%5 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 80%8 models | 50%5 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- J-KU
- TURBRO
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | J-KU | TURBRO |
|---|---|---|
| Non-ducted, up to 1.5 tons | 6 · index 62% | 6 · index 52% |
| Non-ducted, 2 tons | 2 · index 63% | 3 · index 48% |
| Non-ducted, 2.5–3 tons | 1 · index 70% | 1 · index 51% |
| Non-ducted, 3.5–4.5 tons | 1 · index 45% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | J-KUCold-climate score, best model | TURBROCold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 83.4(50 is the typical model of its size class) (higher)JKS09HP230V1XCwith ductless indoor unit JKS09HP230V1XE5 of 6 models qualify · AHRI 211583739 | 47.5(50 is the typical model of its size class)GL12K230-Owith ductless indoor unit GL12K230-I5 of 6 models qualify · AHRI 212386867 |
| Non-ducted, 2 tons | 64.4(50 is the typical model of its size class)JKS-24H2HP-M3O2 of 2 models qualify · AHRI 213286754 | None on this board (0 of 3 models qualify) |
| Non-ducted, 2.5–3 tons | 64.0(50 is the typical model of its size class)JKS-36H2HP-M4O1 of 1 models qualify · AHRI 213286756 | None on this board (0 of 1 models qualify) |
| Non-ducted, 3.5–4.5 tons | 41.8(50 is the typical model of its size class)JKS-42H2HP-M5O1 of 1 models qualify · AHRI 213286755 | No models in this size class |
All-around best
| Size and duct type | J-KUAll-around score, best model | TURBROAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 89.2(50 is the typical model of its size class) (higher)JKS09HP230V1XCwith ductless indoor unit JKS09HP230V1XE6 of 6 models have all five ratings · AHRI 211583739 | 60.6(50 is the typical model of its size class)GL9K230-Owith ductless indoor unit GL9K230-I6 of 6 models have all five ratings · AHRI 214783953 |
| Non-ducted, 2 tons | 71.3(50 is the typical model of its size class) (higher)JKS-24H2HP-M3O2 of 2 models have all five ratings · AHRI 213286754 | 49.4(50 is the typical model of its size class)GL-M24/OAlso listed as GL-M27/O3 of 3 models have all five ratings · AHRI 214783955 |
| Non-ducted, 2.5–3 tons | 69.5(50 is the typical model of its size class) (higher)JKS-36H2HP-M4O1 of 1 models have all five ratings · AHRI 213286756 | 51.2(50 is the typical model of its size class)GL-M36/O1 of 1 models have all five ratings · AHRI 214783956 |
| Non-ducted, 3.5–4.5 tons | 44.5(50 is the typical model of its size class)JKS-42H2HP-M5O1 of 1 models have all five ratings · AHRI 213286755 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | J-KU | TURBRO |
|---|---|---|
| COP at 5°F | beats 97% · 2.41JKS12HP230V1XCNon-ducted, up to 1.5 tons | beats 26% · 1.80GL24K230-ONon-ducted, 2 tons |
| Capacity retention at 5°F | beats 99% · 113%JKS-36H2HP-M4ONon-ducted, 2.5–3 tons | beats 64% · 77%GL9K230-ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 79% · 10.5JKS09HP230V1XCNon-ducted, up to 1.5 tons | beats 57% · 9.5GL12K230-ONon-ducted, up to 1.5 tons |
| SEER2 | beats 96% · 27.5JKS09HP230V1XCNon-ducted, up to 1.5 tons | beats 85% · 22.0GL-M24/OAlso listed as GL-M27/ONon-ducted, 2 tons |
| EER2 | beats 93% · 15.5JKS09HP230V1XCNon-ducted, up to 1.5 tons | beats 68% · 13.0GL12K230-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 92% · 18,000 Btu/hJKS-18H2HP-M2ONon-ducted, up to 1.5 tons | beats 84% · 13,800 Btu/hGL-M18/ONon-ducted, up to 1.5 tons |