LPS Legacy vs RUSSELL heat pumps
Measured against models of the same size and duct type, LPS Legacy scores higher on 4 of the 6 ratings. LPS Legacy has 58 outdoor models, RUSSELL has 60 outdoor models. LPS Legacy and RUSSELL have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- LPS Legacy
- RUSSELL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | LPS Legacy | RUSSELL |
|---|---|---|
| Efficiency index | 53% (higher)median — | 49% (higher)median — |
| COP at 5°F | 52%median 1.97 | 80%median 2.20 |
| Capacity retention at 5°F | 50% (higher)median 67% | 45% (higher)median 58% |
| HSPF2 | 62% (higher)median 9.2 | 25% (higher)median 7.2 |
| SEER2 | 55% (higher)median 18.5 | 31% (higher)median 14.3 |
| EER2 | 42%median 10.6 | 42%median 10.6 |
| Heating capacity at 5°F | 50% (higher)median 19,000 Btu/h | 43% (higher)median 24,200 Btu/h |
| Outdoor models | 58 | 60 |
| AHRI certifications | 146 | 1,231 |
Share of models meeting each standard
| Standard | LPS Legacy | RUSSELL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 58.6%34 models | 16.7%10 models |
| CEE 2026 Tier 1 (Split ASHP) | 55.2%32 models | 16.7%10 models |
| CEE Advanced Tier (Split ASHP) | 3.4%2 models | 3.3%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 39.7%23 models | 13.3%8 models |
| DOE Cold Climate Heat Pump Challenge | 3.4%2 models | 3.3%2 models |
| ENERGY STAR Cold Climate | 43.1%25 models | 21.7%13 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- LPS Legacy
- RUSSELL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | LPS Legacy | RUSSELL |
|---|---|---|
| Ducted, up to 1.5 tons | 6 · index 62% | 2 · index 27% |
| Ducted, 2 tons | 4 · index 65% | 7 · index 50% |
| Ducted, 2.5 to 3 tons | 13 · index 53% | 17 · index 52% |
| Ducted, 3.5 to 4.5 tons | 8 · index 54% | 26 · index 50% |
| Ducted, 5 tons and up | 3 · index 51% | 8 · index 70% |
| Non-ducted, up to 1.5 tons | 20 · index 54% | None |
| Non-ducted, 2 tons | 4 · index 48% | None |
| Non-ducted, 2.5 to 3 tons | 13 · index 49% | None |
| Non-ducted, 3.5 to 4.5 tons | 7 · index 46% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | LPS LegacyCold-climate score, best model | RUSSELLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 81.6(50 is the typical model of its size class)DLCSRBH18AAKwith ducted air handler DLFSDAH18XHK5 of 6 models qualify · AHRI 211756586 | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | 79.6(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ducted air handler DLFSDAH24XAK4 of 4 models qualify · AHRI 211756579 | 74.8(50 is the typical model of its size class)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU2 of 7 models qualify · AHRI 213372369 |
| Ducted, 2.5 to 3 tons | 78.7(50 is the typical model of its size class)DLCURAH36ABKwith ducted air handler DLFULAH36XCX + CI3 of 13 models qualify · AHRI 213372201 | 80.5(50 is the typical model of its size class) (higher)SP18AZ36AJVCwith ducted air handler SHMVZ6021SEACA2 of 17 models qualify · AHRI 210106900 |
| Ducted, 3.5 to 4.5 tons | 75.1(50 is the typical model of its size class)DLCURAH48ABKwith ducted air handler DLFUAAH60XAK4 of 8 models qualify · AHRI 217197708 | 76.4(50 is the typical model of its size class) (higher)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S962V1005A21M4S4 of 26 models qualify · AHRI 210106968 |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | None on this board (0 of 8 models qualify) |
| Non-ducted, up to 1.5 tons | 89.8(50 is the typical model of its size class)DLCSRBH06AAKwith ductless indoor unit DLFSHCH06XAK10 of 20 models qualify · AHRI 211756600 | No models in this size class |
| Non-ducted, 2 tons | 87.1(50 is the typical model of its size class)DLCSRBH24AAKwith ductless indoor unit DLFSCBH24XAK2 of 4 models qualify · AHRI 211756560 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 74.4(50 is the typical model of its size class)DLCMHBH36DAK2 of 13 models qualify · AHRI 211756577 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 80.7(50 is the typical model of its size class)DLCMHBH48EAK3 of 7 models qualify · AHRI 211756575 | No models in this size class |
All-around best
| Size and duct type | LPS LegacyAll-around score, best model | RUSSELLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)DLCSRBH09AAKwith ducted air handler DLFSDAH09XAK6 of 6 models have all five ratings · AHRI 211756568 | 34.6(50 is the typical model of its size class)SP15AZ18AJ2Nwith ducted air handler SH2CZ2417STANN2 of 2 models have all five ratings · AHRI 211627516 |
| Ducted, 2 tons | 80.2(50 is the typical model of its size class)DLCSRBH24AAKwith ducted air handler DLFSDAH24XAK4 of 4 models have all five ratings · AHRI 211756579 | 83.6(50 is the typical model of its size class) (higher)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU4 of 7 models have all five ratings · AHRI 213372369 |
| Ducted, 2.5 to 3 tons | 72.1(50 is the typical model of its size class)DLCMHBH30DAK12 of 13 models have all five ratings · AHRI 211756500 | 87.1(50 is the typical model of its size class) (higher)SP18AZ36AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z6 of 17 models have all five ratings · AHRI 210589394 |
| Ducted, 3.5 to 4.5 tons | 82.1(50 is the typical model of its size class) (higher)DLCMHBH48EAK7 of 8 models have all five ratings · AHRI 211756576 | 80.4(50 is the typical model of its size class)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z9 of 26 models have all five ratings · AHRI 210589350 |
| Ducted, 5 tons and up | 57.2(50 is the typical model of its size class)DLCLRCH58AAKwith ducted air handler DLFLDAH58XHK3 of 3 models have all five ratings · AHRI 211756477 | 70.0(50 is the typical model of its size class) (higher)SP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace S97MV1005A21DHS1 of 8 models have all five ratings · AHRI 212387320 |
| Non-ducted, up to 1.5 tons | 92.3(50 is the typical model of its size class)DLCSRBH06AAKwith ductless indoor unit DLFSHCH06XAK19 of 20 models have all five ratings · AHRI 211756600 | No models in this size class |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class)DLCSRBH24AAKwith ductless indoor unit DLFSHCH24XAK4 of 4 models have all five ratings · AHRI 211756584 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 71.5(50 is the typical model of its size class)DLCMHBH36DAK11 of 13 models have all five ratings · AHRI 211756577 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 73.9(50 is the typical model of its size class)DLCMHBH48EAK5 of 7 models have all five ratings · AHRI 211756575 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | LPS Legacy | RUSSELL |
|---|---|---|
| COP at 5°F | beats 92% · 2.21DLCSRBH24AAKNon-ducted, 2 tons | beats 98% · 2.60SP15AZ60AJ2NDucted, 5 tons and up |
| Capacity retention at 5°F | beats 96% · 114%DLCPRBH09AAKNon-ducted, up to 1.5 tons | beats 100% · 105%SP18AZ48AJVCDucted, 3.5 to 4.5 tons |
| HSPF2 | beats 100% · 15.0DLCPRBH09AAKNon-ducted, up to 1.5 tons | beats 75% · 9.5RD17AZ24AJ3NDucted, 2 tons |
| SEER2 | beats 99% · 20.9DLCMHBH48EAKDucted, 3.5 to 4.5 tons | beats 92% · 20.0SP18AZ36AJVCDucted, 2.5 to 3 tons |
| EER2 | beats 98% · 16.2DLCSRBH09AAKNon-ducted, up to 1.5 tons | beats 91% · 12.5SP18AZ36AJVCDucted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 95% · 48,500 Btu/hDLCURAH60ABKDucted, 3.5 to 4.5 tons | beats 100% · 43,500 Btu/hSP18AZ36AJVCDucted, 2.5 to 3 tons |