Skip to content

LUORISE vs Zenaire heat pumps

Measured against models of the same size and duct type, Zenaire scores higher on 3 of the 6 ratings. LUORISE has 12 outdoor models, Zenaire has 12 outdoor models. LUORISE and Zenaire have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
LUORISE and Zenaire on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Zenaire scores higher on 3 of the 6 ratings.
  • LUORISE
  • Zenaire
  • Other ranked manufacturers
LUORISEZenaire

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingLUORISEZenaire
Efficiency index22%median ——median —
COP at 5°F20%median 1.80—median —
Capacity retention at 5°F33%median 70%—median —
HSPF217%median 8.529%median 7.5
SEER225%median 19.030%median 14.3
EER215%median 10.052%median 11.5
Heating capacity at 5°F33%median 8,600 Btu/h—median —
Outdoor models1212
AHRI certifications1216

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardLUORISEZenaire
CEE 2025 Tier 1 (Split ASHP)83.3%10 models0%0 models
CEE 2026 Tier 1 (Split ASHP)66.7%8 models0%0 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)66.7%8 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 0 groups where both have models
  • LUORISE
  • Zenaire
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeLUORISEZenaire
Ducted, up to 1.5 tonsNone1 · index —
Ducted, 2 tonsNone2 · index —
Ducted, 2.5–3 tonsNone3 · index —
Ducted, 3.5–4.5 tonsNone5 · index —
Non-ducted, up to 1.5 tons10 · index 21%None
Non-ducted, 2 tons2 · index 25%None
Non-ducted, 2.5–3 tonsNone1 · index —

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeLUORISECold-climate score, best modelZenaireCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 1 models qualify)
Ducted, 2 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Ducted, 2.5–3 tonsNo models in this size classNone on this board (0 of 3 models qualify)
Ducted, 3.5–4.5 tonsNo models in this size classNone on this board (0 of 5 models qualify)
Non-ducted, up to 1.5 tons28.4(50 is the typical model of its size class)L01-12K1V-19S-P-Owith ductless indoor unit L01-12K1V-19S-WC-IAlso listed as L01-12K1V-19S-O, L01-12K2V-19S-P-O, L01-12K2V-19S-O8 of 10 models qualify · AHRI 214390714No models in this size class
Non-ducted, 2 tonsNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, 2.5–3 tonsNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeLUORISEAll-around score, best modelZenaireAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 1 models have all five ratings)
Ducted, 2 tonsNo models in this size classNone on this board (0 of 2 models have all five ratings)
Ducted, 2.5–3 tonsNo models in this size classNone on this board (0 of 3 models have all five ratings)
Ducted, 3.5–4.5 tonsNo models in this size classNone on this board (0 of 5 models have all five ratings)
Non-ducted, up to 1.5 tons23.6(50 is the typical model of its size class)L01-12K1V-19S-P-Owith ductless indoor unit L01-12K1V-19S-WC-IAlso listed as L01-12K1V-19S-O, L01-12K2V-19S-P-O, L01-12K2V-19S-O10 of 10 models have all five ratings · AHRI 214390714No models in this size class
Non-ducted, 2 tons24.8(50 is the typical model of its size class)L01-24K2V-19S-P-Owith ductless indoor unit L01-24K2V-19S-WC-IAlso listed as L01-24K2V-19S-O2 of 2 models have all five ratings · AHRI 214390722No models in this size class
Non-ducted, 2.5–3 tonsNo models in this size classNone on this board (0 of 1 models have all five ratings)

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingLUORISEZenaire
COP at 5°Fbeats 26% · 1.80L01-24K2V-19S-P-OAlso listed as L01-24K2V-19S-ONon-ducted, 2 tons—
Capacity retention at 5°Fbeats 46% · 70%L01-12K1V-19S-P-OAlso listed as L01-12K1V-19S-O, L01-12K2V-19S-P-O, L01-12K2V-19S-ONon-ducted, up to 1.5 tons—
HSPF2beats 21% · 8.5L01-24K2V-19S-P-OAlso listed as L01-24K2V-19S-ONon-ducted, 2 tonsbeats 49% · 8.1AHP48B18RDucted, 3.5–4.5 tons
SEER2beats 35% · 19.0L01-24K2V-19S-P-OAlso listed as L01-24K2V-19S-ONon-ducted, 2 tonsbeats 65% · 16.0AHP48B18RDucted, 3.5–4.5 tons
EER2beats 25% · 10.0L01-24K2V-19S-P-OAlso listed as L01-24K2V-19S-ONon-ducted, 2 tonsbeats 76% · 12.2AHP24B18RDucted, 2 tons
Heating capacity at 5°Fbeats 61% · 11,600 Btu/hL01-18K2V-19S-P-OAlso listed as L01-18K2V-19S-ONon-ducted, up to 1.5 tons—

More comparisons