Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Mitsubishi Electric vs TCL: heat pump ratings compared
Against heat pumps of the same size and type, a typical Mitsubishi Electric model beats 60% and a typical TCL model 49%. Mitsubishi Electric rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Mitsubishi Electric
60%
of similar heat pumps beaten by its typical model
Well above average156 models listed
TCL
49%
of similar heat pumps beaten by its typical model
About average177 models listed
- Efficiency on a 5°F dayCOP at 5°FMitsubishi Electric: Beats 55%TCL: Beats 36%
- Heating power kept at 5°FCapacity at 5°F vs 47°FMitsubishi Electric: Beats 54%TCL: Beats 50%
- Winter-long heating efficiencyHSPF2Mitsubishi Electric: Beats 66%TCL: Beats 52%
- Summer-long cooling efficiencySEER2Mitsubishi Electric: Beats 63%TCL: Beats 59%
- Hot-day cooling efficiencyEER2Mitsubishi Electric: Beats 60%TCL: Beats 41%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Mitsubishi Electric
- 81%
- TCL
- 76%
Xcel CC
- Mitsubishi Electric
- 67%
- TCL
- 72%
CEE Advanced
- Mitsubishi Electric
- 10%
- TCL
- 0%
ENERGY STAR CC
- Mitsubishi Electric
- 66%
- TCL
- 64%
All-around best, ducted up to 1.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Mitsubishi Electric
- 1SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NLMitsubishi Electric1.5 tons · 15,000 Btu/h · DuctedCold-climate pick, score 85.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Great
- Winter efficiency
- 10.2 (HSPF2)
- Great
- Cooling efficiency
- 17.2 (SEER2)
- Good
- Hot-day cooling
- 13.0 (EER2)
- Great
- 2SUZ-AA18NLHZ***with ducted air handler SEZ-AD18NLMitsubishi Electric1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 83.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 111% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 17.0 (SEER2)
- Good
- Hot-day cooling
- 12.8 (EER2)
- Great
- 3SUZ-AA12NLHZ***with ducted air handler PEAD-AA12NLMitsubishi Electric1 ton · 12,000 Btu/h · DuctedCold-climate pick, score 75.5Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.06 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 17.0 (SEER2)
- Good
- Hot-day cooling
- 13.6 (EER2)
- Top 10%
TCL
- 1TMH18HEI2NAS0U25*TCLAlso listed as H18FMHD3XPC1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 55.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 105% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.0 (HSPF2)
- Below the middle
- Cooling efficiency
- 21.5 (SEER2)
- Top 10%
- Hot-day cooling
- 13.0 (EER2)
- Great
- 2TMH18HEI2NAO0U24TCLAlso listed as H18FMH22XPC1.5 tons · 17,000 Btu/h · DuctedCold-climate pick, score 57.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 84% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 21.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3TSH09HEI2NAO0T24*with ducted air handler TDH09IEI2NAD24TCL1 ton · 9,500 Btu/h · DuctedCold-climate pick, score 59.0Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 78% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.85 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 19.6 (SEER2)
- Good
- Hot-day cooling
- 12.0 (EER2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.