Skip to content

Mitsubishi Electric vs TCL heat pumps

Measured against models of the same size and duct type, Mitsubishi Electric scores higher on 6 of the 6 ratings. Mitsubishi Electric has 156 outdoor models, TCL has 177 outdoor models. TCL has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Mitsubishi Electric and TCL on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Mitsubishi Electric scores higher on 6 of the 6 ratings.
  • Mitsubishi Electric
  • TCL
  • Other ranked manufacturers
Mitsubis…TCL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingMitsubishi ElectricTCL
Efficiency index60% (higher)median — · 6th ranked49% (higher)median —
COP at 5°F55% (higher)median 2.00 · 18th ranked36% (higher)median 1.89
Capacity retention at 5°F54% (higher)median 71% · 13th ranked50% (higher)median 75%
HSPF266% (higher)median 10.0 · 6th ranked52% (higher)median 9.5
SEER263% (higher)median 20.0 · 4th ranked59% (higher)median 20.0
EER260% (higher)median 12.5 · 7th ranked41% (higher)median 11.2
Heating capacity at 5°F63% (higher)median 20,500 Btu/h · 6th ranked51% (higher)median 17,000 Btu/h
Outdoor models156177
AHRI certifications523636

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardMitsubishi ElectricTCL
CEE 2025 Tier 1 (Split ASHP)80.8%126 models75.7%134 models
CEE 2026 Tier 1 (Split ASHP)80.8%126 models75.7%134 models
CEE Advanced Tier (Split ASHP)9.6%15 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)66.7%104 models72.3%128 models
DOE Cold Climate Heat Pump Challenge9.6%15 models0%0 models
ENERGY STAR Cold Climate66%103 models64.4%114 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • Mitsubishi Electric
  • TCL
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeMitsubishi ElectricTCL
Ducted, up to 1.5 tons25 · index 62%10 · index 62%
Ducted, 2 tons10 · index 61%11 · index 49%
Ducted, 2.5–3 tons29 · index 62%19 · index 59%
Ducted, 3.5–4.5 tons29 · index 56%22 · index 51%
Ducted, 5 tons and up10 · index 54%None
Non-ducted, up to 1.5 tons60 · index 64%86 · index 47%
Non-ducted, 2 tons13 · index 61%18 · index 41%
Non-ducted, 2.5–3 tons21 · index 60%29 · index 47%
Non-ducted, 3.5–4.5 tons18 · index 54%12 · index 46%
Non-ducted, 5 tons and up6 · index 67%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeMitsubishi ElectricCold-climate score, best modelTCLCold-climate score, best model
Ducted, up to 1.5 tons85.6(50 is the typical model of its size class) (higher)SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NL10 of 24 models qualify · AHRI 21573491867.5(50 is the typical model of its size class)H18TDHXPCwith ducted air handler H18FAHUDE10 of 10 models qualify · AHRI 218332482
Ducted, 2 tons78.7(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ducted air handler PVA-AA24NL8 of 10 models qualify · AHRI 21869702870.0(50 is the typical model of its size class)H24TDHXPCwith ducted air handler H24FAHUDE11 of 12 models qualify · AHRI 218332483
Ducted, 2.5–3 tons88.7(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ducted air handler PVA-AA30NL20 of 30 models qualify · AHRI 21869704167.2(50 is the typical model of its size class)H30TDHXPCwith ducted air handler H30FAHUDE16 of 18 models qualify · AHRI 218332484
Ducted, 3.5–4.5 tons80.2(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ-**18 of 29 models qualify · AHRI 21713588069.4(50 is the typical model of its size class)H48SDH20XQCwith ducted air handler H48APH20UDEAlso listed as THH48HDI2NAJ0H2621 of 22 models qualify · AHRI 218453819
Ducted, 5 tons and up78.1(50 is the typical model of its size class)MXZ-SM60NLHZ-**6 of 10 models qualify · AHRI 217643004No models in this size class
Non-ducted, up to 1.5 tons97.5(50 is the typical model of its size class) (higher)MUZ-FX06NLHZ***with ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ243 of 60 models qualify · AHRI 21561112470.9(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2566 of 86 models qualify · AHRI 218028413
Non-ducted, 2 tons88.4(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ductless indoor unit PLA-AE24NL10 of 13 models qualify · AHRI 21869702461.6(50 is the typical model of its size class)H24SBH23XQCwith ductless indoor unit H24SBH23XQE11 of 19 models qualify · AHRI 218451106
Non-ducted, 2.5–3 tons93.8(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NL12 of 21 models qualify · AHRI 21869703768.0(50 is the typical model of its size class)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2519 of 28 models qualify · AHRI 218028414
Non-ducted, 3.5–4.5 tons78.4(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ***Also listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-13 of 18 models qualify · AHRI 21568546748.1(50 is the typical model of its size class)TMH48HEI2NAS0U25Also listed as H48FMHD6XPC11 of 12 models qualify · AHRI 218028416
Non-ducted, 5 tons and up70.0(50 is the typical model of its size class)MXZ-SM60NLHZ-**Also listed as PUMY-HL60NKMU6 of 6 models qualify · AHRI 217643003No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeMitsubishi ElectricAll-around score, best modelTCLAll-around score, best model
Ducted, up to 1.5 tons78.3(50 is the typical model of its size class) (higher)SUZ-AA15NLHZ***with ducted air handler PEAD-AA15NL21 of 22 models have all five ratings · AHRI 21573491872.9(50 is the typical model of its size class)TMH18HEI2NAS0U25*Also listed as H18FMHD3XPC10 of 10 models have all five ratings · AHRI 218625046
Ducted, 2 tons85.1(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ducted air handler PVA-AA24NL12 of 12 models have all five ratings · AHRI 21869702870.0(50 is the typical model of its size class)THH24HDI2NAJ0H26with ducted air handler THH24IDI2NAJ0H2613 of 13 models have all five ratings · AHRI 218467218
Ducted, 2.5–3 tons93.9(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ducted air handler PVA-AA30NL30 of 30 models have all five ratings · AHRI 21869704180.5(50 is the typical model of its size class)TMH27HEI2NAS0U25*17 of 17 models have all five ratings · AHRI 218625047
Ducted, 3.5–4.5 tons70.4(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ-**29 of 29 models have all five ratings · AHRI 21713588067.5(50 is the typical model of its size class)TMH42HEI2NAM0U24Also listed as H42FMH20XPC22 of 22 models have all five ratings · AHRI 215351200
Ducted, 5 tons and up65.4(50 is the typical model of its size class)MXZ-SM60NLHZ-**10 of 10 models have all five ratings · AHRI 217643004No models in this size class
Non-ducted, up to 1.5 tons98.7(50 is the typical model of its size class) (higher)MUZ-FX06NLHZ***with ductless indoor unit MSZ-FX06NLAlso listed as MUZ-FX06NLHZ256 of 60 models have all five ratings · AHRI 21561112482.6(50 is the typical model of its size class)TMH18HEI2NAS0U25Also listed as H18FMHD3XPC, TMH18HEI2NAS0U2580 of 87 models have all five ratings · AHRI 218028413
Non-ducted, 2 tons87.9(50 is the typical model of its size class) (higher)PUZ-AK24NLHZ2***with ductless indoor unit PLA-AE24NL12 of 13 models have all five ratings · AHRI 21869702464.8(50 is the typical model of its size class)H24SBH23XQCwith ductless indoor unit H24SBH23XQE16 of 17 models have all five ratings · AHRI 218451106
Non-ducted, 2.5–3 tons92.8(50 is the typical model of its size class) (higher)PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NL20 of 21 models have all five ratings · AHRI 21869703783.1(50 is the typical model of its size class)TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U2528 of 29 models have all five ratings · AHRI 218028414
Non-ducted, 3.5–4.5 tons85.9(50 is the typical model of its size class) (higher)MXZ-SM48NLHZ***Also listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-18 of 18 models have all five ratings · AHRI 21568546770.2(50 is the typical model of its size class)TMH48HEI2NAS0U25Also listed as H48FMHD6XPC12 of 12 models have all five ratings · AHRI 218028416
Non-ducted, 5 tons and up68.7(50 is the typical model of its size class)MXZ-SM60NLHZ-**Also listed as PUMY-HL60NKMU6 of 6 models have all five ratings · AHRI 217643003No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingMitsubishi ElectricTCL
COP at 5°Fbeats 100% · 2.70PUZ-AK42NL***Non-ducted, 3.5–4.5 tonsbeats 88% · 2.25TSH24HDI2NAL0B25Also listed as H24SVH20XQCNon-ducted, 2 tons
Capacity retention at 5°Fbeats 99% · 140%MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tonsbeats 99% · 125%H24TDHXPCDucted, 2 tons
HSPF2beats 100% · 12.0MXZ-SM36NLHZ***Also listed as PUMY-HL36NKMU, MXZ-SM36NLHZ-Non-ducted, 2.5–3 tonsbeats 96% · 10.5TMH27HEI2NAS0U25*Ducted, 2.5–3 tons
SEER2beats 100% · 35.0MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tonsbeats 99% · 26.5TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U25Non-ducted, 2.5–3 tons
EER2beats 100% · 21.5MUZ-FX06NLHZ***Also listed as MUZ-FX06NLHZ2Non-ducted, up to 1.5 tonsbeats 97% · 14.0TMH27HEI2NAS0U25Also listed as H27FMHD4XPC, TMH27HEI2NAS0U25Non-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 100% · 26,600 Btu/hMUZ-FX24NLHZ***Also listed as MUZ-FX24NLHZ2Non-ducted, up to 1.5 tonsbeats 99% · 30,000 Btu/hH24TDHXPCDucted, 2 tons

More comparisons