Skip to content

MOOVAIR vs Nutech heat pumps

Measured against models of the same size and duct type, MOOVAIR scores higher on 5 of the 6 ratings. MOOVAIR has 55 outdoor models, Nutech has 25 outdoor models. MOOVAIR and Nutech have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
MOOVAIR and Nutech on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, MOOVAIR scores higher on 5 of the 6 ratings.
  • MOOVAIR
  • Nutech
  • Other ranked manufacturers
MOOVAIRNutech

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingMOOVAIRNutech
Efficiency index62% (higher)median —52% (higher)median —
COP at 5°F52% (higher)median 1.9638% (higher)median 1.90
Capacity retention at 5°F66% (higher)median 83%43% (higher)median 65%
HSPF274% (higher)median 9.863% (higher)median 9.3
SEER263%median 19.268%median 19.5
EER250% (higher)median 11.742% (higher)median 10.6
Heating capacity at 5°F66% (higher)median 22,000 Btu/h45% (higher)median 21,400 Btu/h
Outdoor models5525
AHRI certifications15551

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardMOOVAIRNutech
CEE 2025 Tier 1 (Split ASHP)67.3%37 models64%16 models
CEE 2026 Tier 1 (Split ASHP)61.8%34 models48%12 models
CEE Advanced Tier (Split ASHP)3.6%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)54.5%30 models32%8 models
DOE Cold Climate Heat Pump Challenge3.6%2 models0%0 models
ENERGY STAR Cold Climate61.8%34 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • MOOVAIR
  • Nutech
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeMOOVAIRNutech
Ducted, up to 1.5 tons11 · index 62%4 · index 52%
Ducted, 2 tons5 · index 69%2 · index 69%
Ducted, 2.5 to 3 tons11 · index 58%7 · index 54%
Ducted, 3.5 to 4.5 tons10 · index 57%6 · index 55%
Ducted, 5 tons and up3 · index 50%1 · index 42%
Non-ducted, up to 1.5 tons20 · index 73%4 · index 42%
Non-ducted, 2 tons4 · index 60%1 · index 28%
Non-ducted, 2.5 to 3 tons11 · index 57%5 · index 56%
Non-ducted, 3.5 to 4.5 tons8 · index 52%4 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeMOOVAIRCold-climate score, best modelNutechCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class) (higher)DMA09HOS28230E8with ducted air handler DUA09HIDU230X510 of 11 models qualify · AHRI 20774252165.8(50 is the typical model of its size class)NOX330-12HFN1-MW5Wwith ducted air handler NTIU-12HWFN1-M3 of 4 models qualify · AHRI 212941749
Ducted, 2 tons80.6(50 is the typical model of its size class) (higher)DMA24HOS25230E8with ducted air handler DUA24HIDU230X55 of 5 models qualify · AHRI 20774251779.6(50 is the typical model of its size class)NOD30-24HFN1-MU0Wwith ducted air handler NTIU-24HWFN1-M2 of 2 models qualify · AHRI 212941751
Ducted, 2.5 to 3 tons80.0(50 is the typical model of its size class) (higher)DM36HOS25230E3with ducted air handler DM36HIDU230X5Also listed as DMA36HOS28230E87 of 11 models qualify · AHRI 20685324057.7(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M2 of 7 models qualify · AHRI 212941759
Ducted, 3.5 to 4.5 tons86.5(50 is the typical model of its size class)DM48HOS25230E3with ducted air handler DM48HIDU230X5Also listed as DMA48HOS28230E86 of 10 models qualify · AHRI 206853241None on this board (0 of 6 models qualify)
Ducted, 5 tons and upNone on this board (0 of 3 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)DMA06HOS28230E8with ductless indoor unit DMA06HIW25230E8Also listed as DMA09HOS25230E813 of 20 models qualify · AHRI 20774249457.9(50 is the typical model of its size class)NU9WKU1with ductless indoor unit NU9WKU11 of 4 models qualify · AHRI 212941744
Non-ducted, 2 tons87.1(50 is the typical model of its size class)DMA24HOS28230E8with ductless indoor unit DUA24HICU230X53 of 4 models qualify · AHRI 207742511None on this board (0 of 1 models qualify)
Non-ducted, 2.5 to 3 tons80.2(50 is the typical model of its size class) (higher)DMA36HOM25230X33 of 11 models qualify · AHRI 20774254751.5(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M2 of 5 models qualify · AHRI 212941758
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class)DMA48HOM25230X33 of 8 models qualify · AHRI 207742550None on this board (0 of 4 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeMOOVAIRAll-around score, best modelNutechAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)DMA09HOS28230E8with ducted air handler DUA09HIDU230X511 of 11 models have all five ratings · AHRI 20774252164.7(50 is the typical model of its size class)NOX330-12HFN1-MW5Wwith ducted air handler NTIU-12HWFN1-M4 of 4 models have all five ratings · AHRI 212941749
Ducted, 2 tons84.0(50 is the typical model of its size class) (higher)DMA24HOS25230E8with ducted air handler DUA24HIDU230X55 of 5 models have all five ratings · AHRI 20774251780.2(50 is the typical model of its size class)NOD30-24HFN1-MU0Wwith ducted air handler NTIU-24HWFN1-M2 of 2 models have all five ratings · AHRI 212941751
Ducted, 2.5 to 3 tons75.4(50 is the typical model of its size class) (higher)DMA27HOM23230X210 of 11 models have all five ratings · AHRI 20774253371.7(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M7 of 7 models have all five ratings · AHRI 212941759
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)DMA48HOM25230X39 of 10 models have all five ratings · AHRI 20774255163.5(50 is the typical model of its size class)N5OG-48HFN1-MAlso listed as N2OA-48HFN1-M6 of 6 models have all five ratings · AHRI 212941765
Ducted, 5 tons and up54.3(50 is the typical model of its size class) (higher)DM60HOS18230E5with ducted air handler DM60HIDU230X5Also listed as DMC60HOS18230S5A3 of 3 models have all five ratings · AHRI 20400575541.9(50 is the typical model of its size class)NOE30U-60HFN1-MR0with ducted air handler NVC-60HWFN11 of 1 models have all five ratings · AHRI 212941774
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)DMA06HOS28230E8with ductless indoor unit DMA06HIW25230E8Also listed as DMA09HOS25230E818 of 20 models have all five ratings · AHRI 20774249455.4(50 is the typical model of its size class)NU9WKU1with ductless indoor unit NU9WKU14 of 4 models have all five ratings · AHRI 212941744
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)DMA24HOS28230E8with ductless indoor unit DMA24HIW25230E84 of 4 models have all five ratings · AHRI 20774249828.4(50 is the typical model of its size class)NU24WKU1with ductless indoor unit NU24WKU11 of 1 models have all five ratings · AHRI 212941747
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class) (higher)DMA36HOM25230X38 of 11 models have all five ratings · AHRI 20774254768.0(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M5 of 5 models have all five ratings · AHRI 212941758
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class) (higher)DMA48HOM25230X36 of 8 models have all five ratings · AHRI 20774255048.3(50 is the typical model of its size class)N5OG-48HFN1-MAlso listed as N2OA-48HFN1-M4 of 4 models have all five ratings · AHRI 212941764

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingMOOVAIRNutech
COP at 5°Fbeats 98% · 2.45DMA12HOS25230E8Non-ducted, up to 1.5 tonsbeats 87% · 2.01NU36WKU1Non-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 96% · 114%DMA09HOS42230E4Non-ducted, up to 1.5 tonsbeats 93% · 108%NOD30-24HFN1-MU0WDucted, 2 tons
HSPF2beats 100% · 14.5DMB12HOS42230E8Also listed as SHC24VH2AG, DMA12HOS42230E4Non-ducted, up to 1.5 tonsbeats 95% · 9.7N5OG-48HFN1-MAlso listed as N2OA-48HFN1-MDucted, 3.5 to 4.5 tons
SEER2beats 99% · 20.9DMA48HOM25230X3Ducted, 3.5 to 4.5 tonsbeats 98% · 21.0N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-MDucted, 2.5 to 3 tons
EER2beats 99% · 16.5DMB09HOS42230E8Non-ducted, up to 1.5 tonsbeats 75% · 12.2N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-MNon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 98% · 41,000 Btu/hDMA36HOS28230E8Non-ducted, 2.5 to 3 tonsbeats 93% · 27,000 Btu/hNOD30-24HFN1-MU0WDucted, 2 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
MOOVAIR vs Nutech: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,707 models (37.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • MOOVAIR (median, middle 50%)
  • Nutech (median, middle 50%)
Heating capacity, % of its 47°F maximum71%57%COP at maximum capacity1.961.88

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,707100%100%100%100%100%
All rated models, 17°F3,70765%68%76%83%92%
All rated models, 5°F3,70755%58%67%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7072.642.873.13.323.53
All rated models, 17°F3,7071.982.052.22.342.49
All rated models, 5°F3,7071.81.831.922.032.21
MOOVAIR: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
MOOVAIR, 47°F44100%100%100%100%100%
MOOVAIR, 17°F4466%70%78%82%83%
MOOVAIR, 5°F4456%62%71%75%82%
MOOVAIR: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
MOOVAIR, 47°F442.752.913.093.313.56
MOOVAIR, 17°F441.982.042.22.292.41
MOOVAIR, 5°F441.81.861.962.012.27
Nutech: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Nutech, 47°F24100%100%100%100%100%
Nutech, 17°F2462%65%67%71%77%
Nutech, 5°F2454%55%57%63%72%
Nutech: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Nutech, 47°F242.763.073.183.233.45
Nutech, 17°F241.972.092.172.252.41
Nutech, 5°F241.81.81.881.972.06

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy