NAPOLEON vs TRUENORTH heat pumps

Measured against models of the same size and duct type, NAPOLEON scores higher on 6 of the 6 ratings. NAPOLEON has 19 outdoor models, TRUENORTH has 19 outdoor models. NAPOLEON and TRUENORTH have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
NAPOLEON and TRUENORTH on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, NAPOLEON scores higher on 6 of the 6 ratings.
  • NAPOLEON
  • TRUENORTH
  • Other ranked manufacturers
NAPOLEONTRUENORTH

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingNAPOLEONTRUENORTH
Efficiency index63% (higher)median —42% (higher)median —
COP at 5°F58% (higher)median 2.0237% (higher)median 1.80
Capacity retention at 5°F65% (higher)median 84%59% (higher)median 72%
HSPF265% (higher)median 9.747% (higher)median 8.5
SEER264% (higher)median 20.039% (higher)median 17.5
EER256% (higher)median 11.833% (higher)median 10.5
Heating capacity at 5°F68% (higher)median 21,000 Btu/h61% (higher)median 20,000 Btu/h
Outdoor models1919
AHRI certifications11471

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardNAPOLEONTRUENORTH
CEE 2025 Tier 1 (Split ASHP)89.5%17 models57.9%11 models
CEE 2026 Tier 1 (Split ASHP)89.5%17 models52.6%10 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)78.9%15 models68.4%13 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate68.4%13 models57.9%11 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 6 groups where both have models
  • NAPOLEON
  • TRUENORTH
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeNAPOLEONTRUENORTH
Ducted, 2 tons1 · index 61%3 · index 40%
Ducted, 2.5 to 3 tons2 · index 62%5 · index 45%
Ducted, 3.5 to 4.5 tons2 · index 63%3 · index 35%
Ducted, up to 1.5 tonsNone3 · index 29%
Non-ducted, up to 1.5 tons7 · index 65%6 · index 34%
Non-ducted, 2 tons4 · index 68%2 · index 49%
Non-ducted, 2.5 to 3 tons4 · index 55%3 · index 69%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeNAPOLEONCold-climate score, best modelTRUENORTHCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class36.3(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models qualify · AHRI 218593150
Ducted, 2 tonsNo models in this size class50.3(50 is the typical model of its size class)WLWHD(24)ND3MO4 of 4 models qualify · AHRI 218593151
Ducted, 2.5 to 3 tons65.0(50 is the typical model of its size class) (higher)NDHAM-28-O3 of 3 models qualify · AHRI 20768323955.4(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD36AH2/A-D(U)4 of 4 models qualify · AHRI 218828997
Ducted, 3.5 to 4.5 tons60.3(50 is the typical model of its size class) (higher)WSEHV4860RA1-Nwith ducted air handler *G52960+TD2 of 2 models qualify · AHRI 21325028058.2(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)1 of 3 models qualify · AHRI 218828999
Non-ducted, up to 1.5 tons78.7(50 is the typical model of its size class) (higher)NDHAS22-12-Owith ductless indoor unit NDHAS22-12-I5 of 7 models qualify · AHRI 20768323074.0(50 is the typical model of its size class)WLWHD(18)ND3MO5 of 6 models qualify · AHRI 218593147
Non-ducted, 2 tons85.5(50 is the typical model of its size class) (higher)NDHAS26-24-Owith ductless indoor unit NDHAS26-24-I4 of 4 models qualify · AHRI 20768323677.3(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 218593148
Non-ducted, 2.5 to 3 tons74.4(50 is the typical model of its size class)NDHAM-36-O2 of 4 models qualify · AHRI 20768324174.7(50 is the typical model of its size class) (higher)WLWHD(42)ND3MO3 of 3 models qualify · AHRI 218593146

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeNAPOLEONAll-around score, best modelTRUENORTHAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class31.8(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models have all five ratings · AHRI 218593150
Ducted, 2 tons60.8(50 is the typical model of its size class)NS18HV24A36with ducted air handler NPFX24AAlso listed as WSEHV2436RA1-N2 of 2 models have all five ratings · AHRI 20733555260.8(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD24AH2/A-D(U)5 of 5 models have all five ratings · AHRI 218828996
Ducted, 2.5 to 3 tons73.9(50 is the typical model of its size class) (higher)NDHAM-28-O1 of 1 models have all five ratings · AHRI 20768323953.0(50 is the typical model of its size class)WLWHD(30)ND3MO3 of 3 models have all five ratings · AHRI 218593152
Ducted, 3.5 to 4.5 tons63.3(50 is the typical model of its size class)NS18HV48A60with ducted air handler NPFX48AAlso listed as WSEHV4860RA1-N2 of 2 models have all five ratings · AHRI 20733555463.3(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)3 of 3 models have all five ratings · AHRI 218828999
Non-ducted, up to 1.5 tons87.6(50 is the typical model of its size class) (higher)NDHAS26-09-Owith ductless indoor unit NDHAS26-09-I7 of 7 models have all five ratings · AHRI 20768323358.6(50 is the typical model of its size class)WLWHD(18)ND3MO6 of 6 models have all five ratings · AHRI 218593147
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)NDHAS26-24-Owith ductless indoor unit NDHAS26-24-I4 of 4 models have all five ratings · AHRI 20768323672.2(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models have all five ratings · AHRI 218593148
Non-ducted, 2.5 to 3 tons71.5(50 is the typical model of its size class) (higher)NDHAM-36-O3 of 4 models have all five ratings · AHRI 20768324170.9(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models have all five ratings · AHRI 218593146

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingNAPOLEONTRUENORTH
COP at 5°Fbeats 97% · 2.22NDHAS22-24-ONon-ducted, 2 tonsbeats 89% · 2.21WLWHD(18)ND3MONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 93% · 101%NDHAM-36-ONon-ducted, 2.5 to 3 tonsbeats 86% · 89%WLWHD(30)ND3MODucted, 2.5 to 3 tons
HSPF2beats 93% · 11.4NDHAS26-24-ONon-ducted, 2 tonsbeats 82% · 10.0WLWHD(36)ND3MONon-ducted, 2.5 to 3 tons
SEER2beats 98% · 28.1NDHAS26-09-ONon-ducted, up to 1.5 tonsbeats 77% · 17.0WLUD60W/A-D(U)Ducted, 3.5 to 4.5 tons
EER2beats 98% · 16.2NDHAS26-09-ONon-ducted, up to 1.5 tonsbeats 84% · 12.5WLWHD(30)ND3MONon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 95% · 26,000 Btu/hNH25-18H-OAlso listed as NH25-24H-ONon-ducted, 2 tonsbeats 85% · 13,800 Btu/hWLWHD(18)ND3MONon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
NAPOLEON vs TRUENORTH: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • NAPOLEON (median, middle 50%)
  • TRUENORTH (median, middle 50%)
Heating capacity, % of its 47°F maximum77%71%COP at maximum capacity1.801.80

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
NAPOLEON: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
NAPOLEON, 47°F15100%100%100%100%100%
NAPOLEON, 17°F1571%75%80%92%100%
NAPOLEON, 5°F1558%64%77%81%88%
NAPOLEON: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
NAPOLEON, 47°F152.892.963.043.43.4
NAPOLEON, 17°F151.982.022.112.32.49
NAPOLEON, 5°F151.81.81.82.142.24
TRUENORTH: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F17100%100%100%100%100%
TRUENORTH, 17°F1767%73%84%88%91%
TRUENORTH, 5°F1757%61%71%75%77%
TRUENORTH: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F172.942.993.173.273.32
TRUENORTH, 17°F1722.082.32.412.46
TRUENORTH, 5°F171.771.81.81.842.14

Source: NEEP ccASHP list · as of

More comparisons