Skip to content

NG Trade vs WINDAIR heat pumps

Measured against models of the same size and duct type, NG Trade scores higher on 6 of the 6 ratings. NG Trade has 15 outdoor models, WINDAIR has 15 outdoor models. NG Trade and WINDAIR have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
NG Trade and WINDAIR on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, NG Trade scores higher on 6 of the 6 ratings.
  • NG Trade
  • WINDAIR
  • Other ranked manufacturers
NG TradeWINDAIR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingNG TradeWINDAIR
Efficiency index56% (higher)median —32% (higher)median —
COP at 5°F50% (higher)median 1.9016% (higher)median 1.75
Capacity retention at 5°F41% (higher)median 67%31% (higher)median 66%
HSPF259% (higher)median 9.226% (higher)median 8.5
SEER267% (higher)median 21.434% (higher)median 18.5
EER255% (higher)median 12.245% (higher)median 10.9
Heating capacity at 5°F43% (higher)median 12,600 Btu/h30% (higher)median 8,400 Btu/h
Outdoor models1515
AHRI certifications2515

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardNG TradeWINDAIR
CEE 2025 Tier 1 (Split ASHP)80%12 models60%9 models
CEE 2026 Tier 1 (Split ASHP)73.3%11 models46.7%7 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)46.7%7 models20%3 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate33.3%5 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • NG Trade
  • WINDAIR
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeNG TradeWINDAIR
Ducted, up to 1.5 tons1 · index 60%None
Ducted, 2.5 to 3 tons2 · index 64%None
Ducted, 3.5 to 4.5 tons1 · index 64%None
Non-ducted, up to 1.5 tons9 · index 56%12 · index 33%
Non-ducted, 2 tons2 · index 48%2 · index 26%
Non-ducted, 2.5 to 3 tons3 · index 53%1 · index 30%
Non-ducted, 3.5 to 4.5 tons1 · index 48%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeNG TradeCold-climate score, best modelWINDAIRCold-climate score, best model
Ducted, up to 1.5 tons52.6(50 is the typical model of its size class)MOBMH180C1 of 1 models qualify · AHRI 213307863No models in this size class
Ducted, 2.5 to 3 tons57.6(50 is the typical model of its size class)MOBMH270C1 of 2 models qualify · AHRI 213307866No models in this size class
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, up to 1.5 tons76.3(50 is the typical model of its size class) (higher)OMEGA181Ewith ductless indoor unit IMEGA181E4 of 9 models qualify · AHRI 21444265576.0(50 is the typical model of its size class)DWH09UW3SXETE00/Owith ductless indoor unit DWH09UW3SXETE00/I4 of 12 models qualify · AHRI 202021941
Non-ducted, 2 tons66.2(50 is the typical model of its size class)OMEGA241Ewith ductless indoor unit IMEGA241E1 of 2 models qualify · AHRI 214377801None on this board (0 of 2 models qualify)
Non-ducted, 2.5 to 3 tons51.5(50 is the typical model of its size class)MOBMH270C1 of 3 models qualify · AHRI 213307865None on this board (0 of 1 models qualify)
Non-ducted, 3.5 to 4.5 tonsNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeNG TradeAll-around score, best modelWINDAIRAll-around score, best model
Ducted, up to 1.5 tons59.8(50 is the typical model of its size class)MOBMH180C1 of 1 models have all five ratings · AHRI 213307863No models in this size class
Ducted, 2.5 to 3 tons71.7(50 is the typical model of its size class)MOBMH270C2 of 2 models have all five ratings · AHRI 213307866No models in this size class
Ducted, 3.5 to 4.5 tons63.5(50 is the typical model of its size class)MOBMH480C1 of 1 models have all five ratings · AHRI 213867401No models in this size class
Non-ducted, up to 1.5 tons85.0(50 is the typical model of its size class)OMEGA091Ewith ductless indoor unit IMEGA091E9 of 9 models have all five ratings · AHRI 21437779885.6(50 is the typical model of its size class) (higher)DWH09UW3SXETE00/Owith ductless indoor unit DWH09UW3SXETE00/I12 of 12 models have all five ratings · AHRI 202021941
Non-ducted, 2 tons73.3(50 is the typical model of its size class) (higher)OMEGA241Ewith ductless indoor unit IMEGA241E2 of 2 models have all five ratings · AHRI 21437780140.8(50 is the typical model of its size class)DWH24UR3SDBTE/Owith ductless indoor unit DWH24UR3SDBTE/I2 of 2 models have all five ratings · AHRI 202021940
Non-ducted, 2.5 to 3 tons68.0(50 is the typical model of its size class) (higher)MOBMH270C3 of 3 models have all five ratings · AHRI 21330786529.7(50 is the typical model of its size class)DWH30UR3SDKVQ/Owith ductless indoor unit DWH30UR3SDKVQ/I1 of 1 models have all five ratings · AHRI 202021947
Non-ducted, 3.5 to 4.5 tons48.3(50 is the typical model of its size class)MOBMH480C1 of 1 models have all five ratings · AHRI 213867400No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingNG TradeWINDAIR
COP at 5°Fbeats 97% · 2.22OMEGA241ENon-ducted, 2 tonsbeats 79% · 2.10DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 79% · 99%OMEGA181ENon-ducted, up to 1.5 tonsbeats 66% · 78%DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
HSPF2beats 95% · 9.7MOBMH480CDucted, 3.5 to 4.5 tonsbeats 79% · 10.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
SEER2beats 98% · 21.0MOBMH270CDucted, 2.5 to 3 tonsbeats 96% · 27.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
EER2beats 95% · 15.8OMEGA091ENon-ducted, up to 1.5 tonsbeats 93% · 15.5DWH09UW3SXETE00/ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 91% · 17,742 Btu/hOMEGA181ENon-ducted, up to 1.5 tonsbeats 67% · 11,900 Btu/hDWH18UR3SXATE/ONon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter