Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Nutech vs Panasonic: heat pump ratings compared
Against heat pumps of the same size and type, a typical Nutech model beats 54% and a typical Panasonic model 68%. Panasonic rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Nutech
54%
of similar heat pumps beaten by its typical model
About average28 models listed
Panasonic
68%
of similar heat pumps beaten by its typical model
Well above average29 models listed
- Efficiency on a 5°F dayCOP at 5°FNutech: Beats 58%Panasonic: Beats 64%
- Heating power kept at 5°FCapacity at 5°F vs 47°FNutech: Beats 42%Panasonic: Beats 72%
- Winter-long heating efficiencyHSPF2Nutech: Beats 60%Panasonic: Beats 80%
- Summer-long cooling efficiencySEER2Nutech: Beats 64%Panasonic: Beats 66%
- Hot-day cooling efficiencyEER2Nutech: Beats 43%Panasonic: Beats 62%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Nutech
- 86%
- Panasonic
- 97%
Xcel CC
- Nutech
- 61%
- Panasonic
- 90%
CEE Advanced
- Nutech
- 0%
- Panasonic
- 21%
ENERGY STAR CC
- Nutech
- 0%
- Panasonic
- 79%
All-around best, ducted up to 1.5 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Nutech
- 1NOX230-09HFN10-M1with ducted air handler NTJ-09HWFN10-M1-DNutech1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 81.3Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.32 (COP at 5°F)
- Great
- Winter efficiency
- 11.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.7 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
- 2NOX430-18HFN10-M1with ducted air handler NTJ-18HWFN10-M1-DNutech1.5 tons · 17,500 Btu/h · DuctedCold-climate pick, score 69.8Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Winter efficiency
- 11.3 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.3 (EER2)
- Top 10%
- 3N3OX430-18HFN10-M1-DNutech1.5 tons · 18,000 Btu/h · DuctedCold-climate pick, score 72.6Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 77% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Good
Panasonic
- 1CU-YM18CBUCwith ducted air handler CS-YM18CD1UWPanasonic1.5 tons · 17,500 Btu/h · DuctedCold-climate pick, score 69.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 71% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Winter efficiency
- 11.3 (HSPF2)
- Top 10%
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.3 (EER2)
- Top 10%
- 2CU-YM9CBUCwith ducted air handler CS-YM9CD2UWPanasonic1 ton · 9,000 Btu/h · DuctedCold-climate pick, score 80.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.25 (COP at 5°F)
- Great
- Winter efficiency
- 11.0 (HSPF2)
- Top 10%
- Cooling efficiency
- 19.5 (SEER2)
- Good
- Hot-day cooling
- 12.8 (EER2)
- Great
- 3CU-3YM18CBUCPanasonic1.5 tons · 19,000 Btu/h · DuctedCold-climate pick, score 70.8Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.0 (SEER2)
- Great
- Hot-day cooling
- 13.0 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view