Skip to content

PERFECTAIRE vs Wells heat pumps

Measured against models of the same size and duct type, PERFECTAIRE scores higher on 4 of the 6 ratings. PERFECTAIRE has 37 outdoor models, Wells has 35 outdoor models. PERFECTAIRE and Wells have no QMID on file and are not ranked. They share hardware: 28 equipment families appear under both names.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
PERFECTAIRE and Wells on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, PERFECTAIRE scores higher on 4 of the 6 ratings.
  • PERFECTAIRE
  • Wells
  • Other ranked manufacturers
PERFECTA…Wells

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingPERFECTAIREWells
Efficiency index58%median —58%median —
COP at 5°F42% (higher)median 1.9041% (higher)median 1.85
Capacity retention at 5°F64% (higher)median 86%61% (higher)median 79%
HSPF268%median 9.570%median 9.5
SEER263%median 19.465%median 20.2
EER251% (higher)median 11.050% (higher)median 11.0
Heating capacity at 5°F61% (higher)median 20,000 Btu/h60% (higher)median 23,000 Btu/h
Outdoor models3735
AHRI certifications7170

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardPERFECTAIREWells
CEE 2025 Tier 1 (Split ASHP)78.4%29 models74.3%26 models
CEE 2026 Tier 1 (Split ASHP)73%27 models68.6%24 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)64.9%24 models60%21 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate64.9%24 models60%21 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • PERFECTAIRE
  • Wells
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typePERFECTAIREWells
Ducted, up to 1.5 tons7 · index 62%2 · index 59%
Ducted, 2 tons4 · index 77%1 · index 53%
Ducted, 2.5 to 3 tons7 · index 64%9 · index 62%
Ducted, 3.5 to 4.5 tons6 · index 61%8 · index 58%
Ducted, 5 tons and upNone1 · index 57%
Non-ducted, up to 1.5 tons15 · index 49%11 · index 56%
Non-ducted, 2 tons3 · index 51%2 · index 50%
Non-ducted, 2.5 to 3 tons6 · index 65%7 · index 58%
Non-ducted, 3.5 to 4.5 tons4 · index 51%4 · index 51%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typePERFECTAIRECold-climate score, best modelWellsCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class) (higher)3PAMSHH09-SZOwith ducted air handler 3PAMSDH097 of 7 models qualify · AHRI 20779662852.6(50 is the typical model of its size class)WMMA-18HFMO2 of 2 models qualify · AHRI 213286761
Ducted, 2 tons79.6(50 is the typical model of its size class) (higher)1KARDA24SZO20.5with ducted air handler 2PAMSDH24Also listed as 1PAMSHH24-SZW-20.5, 3PAMSHH24-SZO4 of 4 models qualify · AHRI 20634812766.9(50 is the typical model of its size class)WUCA-24HFMOwith ducted air handler WUA-24HFMAH1 of 1 models qualify · AHRI 213307899
Ducted, 2.5 to 3 tons74.8(50 is the typical model of its size class)3PAHHSD36-SZOwith ducted air handler 3PAHHSD36-AHU6 of 7 models qualify · AHRI 21125352680.4(50 is the typical model of its size class) (higher)WMCA-27HFMO7 of 9 models qualify · AHRI 213286779
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)3PAMS48-HH-MZO54 of 6 models qualify · AHRI 20765734575.1(50 is the typical model of its size class)WMCA-48HFMO5 of 8 models qualify · AHRI 213286782
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons77.9(50 is the typical model of its size class) (higher)3PAMSHH12-SZOwith ductless indoor unit 3PAMSCONH12-28 of 15 models qualify · AHRI 21041011175.9(50 is the typical model of its size class)WSA-09HFMOwith ductless indoor unit WSA-09HFMI7 of 11 models qualify · AHRI 214421469
Non-ducted, 2 tons87.1(50 is the typical model of its size class) (higher)3PAMSHH24-SZOwith ductless indoor unit 3PAMSCH242 of 3 models qualify · AHRI 20779663563.4(50 is the typical model of its size class)WSA-24HFMOwith ductless indoor unit WSA-24HFMI1 of 2 models qualify · AHRI 214421472
Non-ducted, 2.5 to 3 tons74.4(50 is the typical model of its size class)3PAMS36-HH-MZO44 of 6 models qualify · AHRI 20765734187.5(50 is the typical model of its size class) (higher)WMCA-36HFMO4 of 7 models qualify · AHRI 213307896
Non-ducted, 3.5 to 4.5 tons80.7(50 is the typical model of its size class)3PAMS48-HH-MZO52 of 4 models qualify · AHRI 20765734480.7(50 is the typical model of its size class)WMCA-48HFMO2 of 4 models qualify · AHRI 213286781

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typePERFECTAIREAll-around score, best modelWellsAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)3PAMSHH09-SZOwith ducted air handler 3PAMSDH097 of 7 models have all five ratings · AHRI 20779662859.8(50 is the typical model of its size class)WMMA-18HFMO2 of 2 models have all five ratings · AHRI 213286761
Ducted, 2 tons80.2(50 is the typical model of its size class) (higher)1KARDA24SZO20.5with ducted air handler 2PAMSDH24Also listed as 1PAMSHH24-SZW-20.5, 3PAMSHH24-SZO4 of 4 models have all five ratings · AHRI 20634812766.0(50 is the typical model of its size class)WUCA-24HFMOwith ducted air handler WUA-24HFMAH1 of 1 models have all five ratings · AHRI 213307899
Ducted, 2.5 to 3 tons74.7(50 is the typical model of its size class)3PAMS27-HH-MZO37 of 7 models have all five ratings · AHRI 20765733883.7(50 is the typical model of its size class) (higher)WMCA-36HFMO9 of 9 models have all five ratings · AHRI 213307897
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)3PAMS48-HH-MZO56 of 6 models have all five ratings · AHRI 20765734582.1(50 is the typical model of its size class)WMCA-48HFMO8 of 8 models have all five ratings · AHRI 213286782
Ducted, 5 tons and upNo models in this size class57.2(50 is the typical model of its size class)WSMA-60HFMOwith ducted air handler WSMA-60HFMD1 of 1 models have all five ratings · AHRI 214797744
Non-ducted, up to 1.5 tons85.0(50 is the typical model of its size class)3PAMSHH09-SZOwith ductless indoor unit 3PAMSHH09-UVWAlso listed as 3KARDA09SZO15 of 15 models have all five ratings · AHRI 20761405485.0(50 is the typical model of its size class)WSA-09HFMOwith ductless indoor unit WSA-09HFMI11 of 11 models have all five ratings · AHRI 214421469
Non-ducted, 2 tons71.9(50 is the typical model of its size class)3PAMSHH24-SZOwith ductless indoor unit 3PAMSHH24-UVWAlso listed as 3PAMSHH24-SZO-213 of 3 models have all five ratings · AHRI 20761405671.9(50 is the typical model of its size class)WSA-24HFMOwith ductless indoor unit WSA-24HFMI2 of 2 models have all five ratings · AHRI 214421472
Non-ducted, 2.5 to 3 tons71.5(50 is the typical model of its size class)3PAMS36-HH-MZO45 of 6 models have all five ratings · AHRI 20765734177.3(50 is the typical model of its size class) (higher)WMCA-36HFMO7 of 7 models have all five ratings · AHRI 213307896
Non-ducted, 3.5 to 4.5 tons73.9(50 is the typical model of its size class)3PAMS48-HH-MZO54 of 4 models have all five ratings · AHRI 20765734473.9(50 is the typical model of its size class)WMCA-48HFMO4 of 4 models have all five ratings · AHRI 213286781

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingPERFECTAIREWells
COP at 5°Fbeats 79% · 2.103PAMSH12B-SZONon-ducted, up to 1.5 tonsbeats 84% · 2.16WSB-09HFBONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 93% · 108%3PAMSHH09-SZODucted, up to 1.5 tonsbeats 97% · 101%WMCA-27HFMODucted, 2.5 to 3 tons
HSPF2beats 98% · 12.03PAMSHH09-SZODucted, up to 1.5 tonsbeats 97% · 10.9WMCA-36HFMONon-ducted, 2.5 to 3 tons
SEER2beats 99% · 20.93PAMS48-HH-MZO5Ducted, 3.5 to 4.5 tonsbeats 99% · 20.9WMCA-48HFMODucted, 3.5 to 4.5 tons
EER2beats 95% · 15.83PAMSHH09-SZOAlso listed as 3KARDA09SZONon-ducted, up to 1.5 tonsbeats 95% · 15.8WSA-09HFMONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/h3PAMS18-HH-MZO2Non-ducted, up to 1.5 tonsbeats 96% · 20,000 Btu/hWMCA-18HFMONon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
PERFECTAIRE vs Wells: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • PERFECTAIRE (median, middle 50%)
  • Wells (median, middle 50%)
Heating capacity, % of its 47°F maximum75%66%COP at maximum capacity1.901.89

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
PERFECTAIRE: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
PERFECTAIRE, 47°F28100%100%100%100%100%
PERFECTAIRE, 17°F2867%76%80%88%95%
PERFECTAIRE, 5°F2858%68%75%83%88%
PERFECTAIRE: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
PERFECTAIRE, 47°F282.792.853.093.183.44
PERFECTAIRE, 17°F281.962.012.172.242.35
PERFECTAIRE, 5°F281.81.821.91.982
Wells: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Wells, 47°F33100%100%100%100%100%
Wells, 17°F3365%67%74%80%91%
Wells, 5°F3354%57%66%79%84%
Wells: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Wells, 47°F332.622.83.093.183.41
Wells, 17°F331.922.172.282.37
Wells, 5°F331.81.81.891.952

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy