Both views use the same certified data. This device remembers your choice.
PolarWave vs RUSSELL heat pumps
Measured against models of the same size and duct type, PolarWave scores higher on 5 of the 6 ratings. PolarWave has 58 outdoor models, RUSSELL has 60 outdoor models. PolarWave and RUSSELL have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- PolarWave
- RUSSELL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | PolarWave | RUSSELL |
|---|---|---|
| Efficiency index | 55% (higher)median — | 49% (higher)median — |
| COP at 5°F | 45%median 1.91 | 80%median 2.20 |
| Capacity retention at 5°F | 57% (higher)median 71% | 45% (higher)median 58% |
| HSPF2 | 66% (higher)median 9.4 | 25% (higher)median 7.2 |
| SEER2 | 59% (higher)median 19.0 | 31% (higher)median 14.3 |
| EER2 | 43% (higher)median 10.5 | 42% (higher)median 10.6 |
| Heating capacity at 5°F | 59% (higher)median 20,900 Btu/h | 43% (higher)median 24,200 Btu/h |
| Outdoor models | 58 | 60 |
| AHRI certifications | 135 | 1,231 |
Share of models meeting each standard
| Standard | PolarWave | RUSSELL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 60.3%35 models | 16.7%10 models |
| CEE 2026 Tier 1 (Split ASHP) | 53.4%31 models | 16.7%10 models |
| CEE Advanced Tier (Split ASHP) | 1.7%1 models | 3.3%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 41.4%24 models | 13.3%8 models |
| DOE Cold Climate Heat Pump Challenge | 1.7%1 models | 3.3%2 models |
| ENERGY STAR Cold Climate | 46.6%27 models | 21.7%13 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- PolarWave
- RUSSELL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | PolarWave | RUSSELL |
|---|---|---|
| Ducted, up to 1.5 tons | 8 · index 61% | 2 · index 27% |
| Ducted, 2 tons | 4 · index 69% | 7 · index 50% |
| Ducted, 2.5 to 3 tons | 12 · index 54% | 17 · index 52% |
| Ducted, 3.5 to 4.5 tons | 12 · index 54% | 26 · index 50% |
| Ducted, 5 tons and up | None | 8 · index 70% |
| Non-ducted, up to 1.5 tons | 16 · index 52% | None |
| Non-ducted, 2 tons | 4 · index 45% | None |
| Non-ducted, 2.5 to 3 tons | 12 · index 55% | None |
| Non-ducted, 3.5 to 4.5 tons | 7 · index 51% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | PolarWaveCold-climate score, best model | RUSSELLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM7 of 8 models qualify · AHRI 213433286 | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | 79.6(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB4 of 4 models qualify · AHRI 212316081 | 74.8(50 is the typical model of its size class)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU2 of 7 models qualify · AHRI 213372369 |
| Ducted, 2.5 to 3 tons | 80.0(50 is the typical model of its size class)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB7 of 12 models qualify · AHRI 212316105 | 80.5(50 is the typical model of its size class) (higher)SP18AZ36AJVCwith ducted air handler SHMVZ6021SEACA2 of 17 models qualify · AHRI 210106900 |
| Ducted, 3.5 to 4.5 tons | 86.5(50 is the typical model of its size class) (higher)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB8 of 12 models qualify · AHRI 212316106 | 76.4(50 is the typical model of its size class)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S962V1005A21M4S4 of 26 models qualify · AHRI 210106968 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 8 models qualify) |
| Non-ducted, up to 1.5 tons | 89.8(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC6 of 16 models qualify · AHRI 212316098 | No models in this size class |
| Non-ducted, 2 tons | 86.3(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB1 of 4 models qualify · AHRI 212316084 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 80.2(50 is the typical model of its size class)ACIQ-36Z-HH-M4B4 of 12 models qualify · AHRI 212316091 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 76.8(50 is the typical model of its size class)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB4 of 7 models qualify · AHRI 212316110 | No models in this size class |
All-around best
| Size and duct type | PolarWaveAll-around score, best model | RUSSELLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB8 of 8 models have all five ratings · AHRI 212316078 | 34.6(50 is the typical model of its size class)SP15AZ18AJ2Nwith ducted air handler SH2CZ2417STANN2 of 2 models have all five ratings · AHRI 211627516 |
| Ducted, 2 tons | 80.2(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB4 of 4 models have all five ratings · AHRI 212316081 | 83.6(50 is the typical model of its size class) (higher)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU4 of 7 models have all five ratings · AHRI 213372369 |
| Ducted, 2.5 to 3 tons | 75.4(50 is the typical model of its size class)ES-27Z-M3B12 of 12 models have all five ratings · AHRI 212316124 | 87.1(50 is the typical model of its size class) (higher)SP18AZ36AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z6 of 17 models have all five ratings · AHRI 210589394 |
| Ducted, 3.5 to 4.5 tons | 82.1(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M5B11 of 11 models have all five ratings · AHRI 212316095 | 80.4(50 is the typical model of its size class)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z9 of 26 models have all five ratings · AHRI 210589350 |
| Ducted, 5 tons and up | 42.0(50 is the typical model of its size class)ACIQ-60-EHPBwith ducted air handler ACIQ-60AHB1 of 1 models have all five ratings · AHRI 213433280 | 70.0(50 is the typical model of its size class) (higher)SP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace S97MV1005A21DHS1 of 8 models have all five ratings · AHRI 212387320 |
| Non-ducted, up to 1.5 tons | 92.3(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC16 of 16 models have all five ratings · AHRI 212316098 | No models in this size class |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB4 of 4 models have all five ratings · AHRI 212316074 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 83.4(50 is the typical model of its size class)ACIQ-36Z-HH-M4B10 of 12 models have all five ratings · AHRI 212316091 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 78.0(50 is the typical model of its size class)ACIQ-48Z-HH-M5B7 of 7 models have all five ratings · AHRI 212316094 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | PolarWave | RUSSELL |
|---|---|---|
| COP at 5°F | beats 92% · 2.21ACIQ-24ZPL-HP230BNon-ducted, 2 tons | beats 98% · 2.60SP15AZ60AJ2NDucted, 5 tons and up |
| Capacity retention at 5°F | beats 95% · 113%ACIQ-06ZPL-HP230BNon-ducted, up to 1.5 tons | beats 100% · 105%SP18AZ48AJVCDucted, 3.5 to 4.5 tons |
| HSPF2 | beats 99% · 10.3ACIQ-48ZPL-HP230BDucted, 3.5 to 4.5 tons | beats 75% · 9.5RD17AZ24AJ3NDucted, 2 tons |
| SEER2 | beats 99% · 20.9ACIQ-48Z-HH-M5BDucted, 3.5 to 4.5 tons | beats 92% · 20.0SP18AZ36AJVCDucted, 2.5 to 3 tons |
| EER2 | beats 98% · 16.2ACIQ-09ZPL-HP230BNon-ducted, up to 1.5 tons | beats 91% · 12.5SP18AZ36AJVCDucted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 99% · 56,500 Btu/hACIQ-60ZPL-HP230BNon-ducted, 3.5 to 4.5 tons | beats 100% · 43,500 Btu/hSP18AZ36AJVCDucted, 2.5 to 3 tons |