QUUL vs SUNCHILLERS heat pumps
Measured against models of the same size and duct type, SUNCHILLERS scores higher on 5 of the 6 ratings. QUUL has 8 outdoor models, SUNCHILLERS has 8 outdoor models. QUUL and SUNCHILLERS have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- QUUL
- SUNCHILLERS
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | QUUL | SUNCHILLERS |
|---|---|---|
| Efficiency index | 45%median — | 68%median — |
| COP at 5°F | 74% (higher)median 1.94 | 51% (higher)median 2.00 |
| Capacity retention at 5°F | 29%median 61% | 46%median 68% |
| HSPF2 | 32%median 8.6 | 74%median 10.1 |
| SEER2 | 19%median 16.9 | 88%median 23.7 |
| EER2 | 21%median 9.0 | 71%median 12.6 |
| Heating capacity at 5°F | 25%median 20,200 Btu/h | 46%median 19,500 Btu/h |
| Outdoor models | 8 | 8 |
| AHRI certifications | 8 | 20 |
Share of models meeting each standard
| Standard | QUUL | SUNCHILLERS |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 12.5%1 models | 100%8 models |
| CEE 2026 Tier 1 (Split ASHP) | 12.5%1 models | 87.5%7 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 50%4 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- QUUL
- SUNCHILLERS
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | QUUL | SUNCHILLERS |
|---|---|---|
| Ducted, up to 1.5 tons | None | 2 · index 61% |
| Ducted, 2 tons | None | 1 · index 84% |
| Ducted, 2.5 to 3 tons | None | 3 · index 63% |
| Ducted, 3.5 to 4.5 tons | None | 1 · index 64% |
| Non-ducted, 2.5 to 3 tons | 6 · index 45% | 3 · index 65% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index — | 1 · index 56% |
| Non-ducted, up to 1.5 tons | None | 3 · index 79% |
| Non-ducted, 2 tons | None | 1 · index 79% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | QUULCold-climate score, best model | SUNCHILLERSCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 68.2(50 is the typical model of its size class)12WODU-ULwith ducted air handler 12DIDU-UL2 of 2 models qualify · AHRI 208447612 |
| Ducted, 2 tons | No models in this size class | 80.6(50 is the typical model of its size class)24WODU-ULwith ducted air handler 24DIDU-UL1 of 1 models qualify · AHRI 208447613 |
| Ducted, 2.5 to 3 tons | No models in this size class | None on this board (0 of 3 models qualify) |
| Ducted, 3.5 to 4.5 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | No models in this size class | 86.6(50 is the typical model of its size class)9WODU-ULwith ductless indoor unit 9WIDU-UL1 of 3 models qualify · AHRI 208447609 |
| Non-ducted, 2 tons | No models in this size class | 62.5(50 is the typical model of its size class)24WODU-ULwith ductless indoor unit 24WIDU-UL1 of 1 models qualify · AHRI 208447611 |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 6 models qualify) | None on this board (0 of 3 models qualify) |
| Non-ducted, 3.5 to 4.5 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | QUULAll-around score, best model | SUNCHILLERSAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 61.7(50 is the typical model of its size class)12WODU-ULwith ducted air handler 12DIDU-UL2 of 2 models have all five ratings · AHRI 208447612 |
| Ducted, 2 tons | No models in this size class | 84.0(50 is the typical model of its size class)24WODU-ULwith ducted air handler 24DIDU-UL1 of 1 models have all five ratings · AHRI 208447613 |
| Ducted, 2.5 to 3 tons | No models in this size class | 75.4(50 is the typical model of its size class)M27ODU-UL2P3 of 3 models have all five ratings · AHRI 207804190 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 63.5(50 is the typical model of its size class)M48ODU-UL2P1 of 1 models have all five ratings · AHRI 207804196 |
| Non-ducted, up to 1.5 tons | No models in this size class | 88.8(50 is the typical model of its size class)9WODU-ULwith ductless indoor unit 9WIDU-UL3 of 3 models have all five ratings · AHRI 208447609 |
| Non-ducted, 2 tons | No models in this size class | 78.6(50 is the typical model of its size class)24WODU-ULwith ductless indoor unit 24WIDU-UL1 of 1 models have all five ratings · AHRI 208447611 |
| Non-ducted, 2.5 to 3 tons | 54.4(50 is the typical model of its size class)R.Q.I30.OUTwith ductless indoor unit R.Q.I302 of 6 models have all five ratings · AHRI 210474669 | 78.9(50 is the typical model of its size class) (higher)M27ODU-UL2P3 of 3 models have all five ratings · AHRI 207804189 |
| Non-ducted, 3.5 to 4.5 tons | None on this board (0 of 2 models have all five ratings) | 56.0(50 is the typical model of its size class)M48ODU-UL2P1 of 1 models have all five ratings · AHRI 207804195 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | QUUL | SUNCHILLERS |
|---|---|---|
| COP at 5°F | beats 87% · 2.01R.Q.I36.OUTNon-ducted, 2.5 to 3 tons | beats 97% · 2.3912WODU-ULNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 30% · 61%R.Q.I30.OUTNon-ducted, 2.5 to 3 tons | beats 73% · 86%9WODU-ULNon-ducted, up to 1.5 tons |
| HSPF2 | beats 82% · 10.0R.Q.H.MOU36Also listed as R.Q.MOU36Non-ducted, 2.5 to 3 tons | beats 98% · 11.224WODU-ULDucted, 2 tons |
| SEER2 | beats 65% · 21.0R.Q.I30.OUTNon-ducted, 2.5 to 3 tons | beats 99% · 24.6M27ODU-UL2PNon-ducted, 2.5 to 3 tons |
| EER2 | beats 75% · 12.2R.Q.I30.OUTNon-ducted, 2.5 to 3 tons | beats 97% · 14.024WODU-ULNon-ducted, 2 tons |
| Heating capacity at 5°F | beats 37% · 22,000 Btu/hR.Q.I36.OUTNon-ducted, 2.5 to 3 tons | beats 77% · 12,900 Btu/hM18ODU-UL2PNon-ducted, up to 1.5 tons |