Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ROVSUN vs ROYALTON heat pumps
Measured against models of the same size and duct type, ROVSUN and ROYALTON split the 6 ratings 3–3. ROVSUN has 21 outdoor models, ROYALTON has 21 outdoor models. ROVSUN and ROYALTON have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ROVSUN
- ROYALTON
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ROVSUN | ROYALTON |
|---|---|---|
| Efficiency index | 32%median — | 50%median — |
| COP at 5°F | 22%median 1.80 | 58%median 2.18 |
| Capacity retention at 5°F | 34% (higher)median 66% | 20% (higher)median 50% |
| HSPF2 | 15%median 8.0 | 22%median 6.7 |
| SEER2 | 30% (higher)median 19.0 | 29% (higher)median 15.2 |
| EER2 | 21%median 10.0 | 67%median 11.4 |
| Heating capacity at 5°F | 45% (higher)median 11,600 Btu/h | 20% (higher)median 17,800 Btu/h |
| Outdoor models | 21 | 21 |
| AHRI certifications | 21 | 1,322 |
Share of models meeting each standard
| Standard | ROVSUN | ROYALTON |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3%7 models | 19%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 33.3%7 models | 19%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 23.8%5 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 14.3%3 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ROVSUN
- ROYALTON
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ROVSUN | ROYALTON |
|---|---|---|
| Ducted, up to 1.5 tons | None | 1 · index 47% |
| Ducted, 2 tons | None | 4 · index 45% |
| Ducted, 2.5–3 tons | None | 6 · index 53% |
| Ducted, 3.5–4.5 tons | None | 9 · index 48% |
| Ducted, 5 tons and up | None | 1 · index 63% |
| Non-ducted, up to 1.5 tons | 19 · index 33% | None |
| Non-ducted, 2 tons | 1 · index — | None |
| Non-ducted, 2.5–3 tons | 1 · index 28% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ROVSUNCold-climate score, best model | ROYALTONCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Ducted, 2 tons | No models in this size class | None on this board (0 of 4 models qualify) |
| Ducted, 2.5–3 tons | No models in this size class | None on this board (0 of 6 models qualify) |
| Ducted, 3.5–4.5 tons | No models in this size class | None on this board (0 of 9 models qualify) |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 47.5(50 is the typical model of its size class)TSC-12HA2/I3XI23-Owith ductless indoor unit TSC-12HA2/I3XI23-I5 of 19 models qualify · AHRI 213927362 | No models in this size class |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | ROVSUNAll-around score, best model | ROYALTONAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 53.6(50 is the typical model of its size class)4HP17L18P-**Awith indoor coil EAD4X-30/36B+TDR and furnace 92G1DF070BE121 of 1 models have all five ratings · AHRI 213265346 |
| Ducted, 2 tons | No models in this size class | 61.6(50 is the typical model of its size class)4HP17L24P-**Awith indoor coil EAD4X-30/36B+TDR and furnace 80G1DF090BE162 of 4 models have all five ratings · AHRI 213265357 |
| Ducted, 2.5–3 tons | No models in this size class | 69.9(50 is the typical model of its size class)4HP17L36P-**Awith indoor coil EAD4X-48C+TDR and furnace 80G1DF110CE203 of 6 models have all five ratings · AHRI 213265391 |
| Ducted, 3.5–4.5 tons | No models in this size class | 69.8(50 is the typical model of its size class)4HP17L48P-**Awith indoor coil EA(C;U)1P60C+TDR+TXV and furnace 80G2UH110CE204 of 9 models have all five ratings · AHRI 210326789 |
| Ducted, 5 tons and up | No models in this size class | 67.6(50 is the typical model of its size class)4HP17L60P-**Awith indoor coil EA(C;U)1P60C+TDR+TXV and furnace 80G2UH110CE201 of 1 models have all five ratings · AHRI 212619797 |
| Non-ducted, up to 1.5 tons | 60.2(50 is the typical model of its size class)TSC-12HA2/I3XI23-Owith ductless indoor unit TSC-12HA2/I3XI23-I10 of 19 models have all five ratings · AHRI 213927362 | No models in this size class |
| Non-ducted, 2 tons | None on this board (0 of 1 models have all five ratings) | No models in this size class |
| Non-ducted, 2.5–3 tons | 28.1(50 is the typical model of its size class)TMSC-27HA2/I2XI19-O1 of 1 models have all five ratings · AHRI 213927368 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ROVSUN | ROYALTON |
|---|---|---|
| COP at 5°F | beats 22% · 1.80TSC-18HA2/I2AXI19-OAlso listed as TSC-18HA2/I2XI19-ONon-ducted, up to 1.5 tons | beats 90% · 2.364HP17L30P-**ADucted, 2.5–3 tons |
| Capacity retention at 5°F | beats 60% · 76%TSC-12HA2/I3XI23-ONon-ducted, up to 1.5 tons | beats 37% · 59%4HP17L60P-**ADucted, 3.5–4.5 tons |
| HSPF2 | beats 57% · 9.5TSC-12HA2/I3XI23-ONon-ducted, up to 1.5 tons | beats 62% · 8.54HP17L48P-**ADucted, 3.5–4.5 tons |
| SEER2 | beats 73% · 23.0TSC-09HA1/I3XI22-ONon-ducted, up to 1.5 tons | beats 61% · 16.84HP17L36P-**ADucted, 2.5–3 tons |
| EER2 | beats 68% · 13.0TSC-12HA2/I3XI23-ONon-ducted, up to 1.5 tons | beats 99% · 14.04HP17L24P-**ADucted, 2 tons |
| Heating capacity at 5°F | beats 78% · 13,000 Btu/hTMSC-18HA2/I2XI20-ONon-ducted, up to 1.5 tons | beats 51% · 32,000 Btu/h4HP17L60P-**ADucted, 5 tons and up |