Both views use the same certified data. This device remembers your choice.
SEA BREEZE+ vs TRUENORTH heat pumps
Measured against models of the same size and duct type, SEA BREEZE+ scores higher on 6 of the 6 ratings. SEA BREEZE+ has 19 outdoor models, TRUENORTH has 19 outdoor models. SEA BREEZE+ and TRUENORTH have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- SEA BREEZE+
- TRUENORTH
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | SEA BREEZE+ | TRUENORTH |
|---|---|---|
| Efficiency index | 66% (higher)median — | 42% (higher)median — |
| COP at 5°F | 47% (higher)median 1.90 | 37% (higher)median 1.80 |
| Capacity retention at 5°F | 69% (higher)median 85% | 59% (higher)median 72% |
| HSPF2 | 78% (higher)median 10.6 | 47% (higher)median 8.5 |
| SEER2 | 73% (higher)median 21.0 | 39% (higher)median 17.5 |
| EER2 | 63% (higher)median 12.5 | 33% (higher)median 10.5 |
| Heating capacity at 5°F | 67% (higher)median 20,000 Btu/h | 61% (higher)median 20,000 Btu/h |
| Outdoor models | 19 | 19 |
| AHRI certifications | 69 | 71 |
Share of models meeting each standard
| Standard | SEA BREEZE+ | TRUENORTH |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 89.5%17 models | 57.9%11 models |
| CEE 2026 Tier 1 (Split ASHP) | 84.2%16 models | 52.6%10 models |
| CEE Advanced Tier (Split ASHP) | 5.3%1 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 84.2%16 models | 68.4%13 models |
| DOE Cold Climate Heat Pump Challenge | 5.3%1 models | 0%0 models |
| ENERGY STAR Cold Climate | 89.5%17 models | 57.9%11 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- SEA BREEZE+
- TRUENORTH
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | SEA BREEZE+ | TRUENORTH |
|---|---|---|
| Ducted, up to 1.5 tons | 8 · index 67% | 3 · index 29% |
| Ducted, 2 tons | 4 · index 78% | 3 · index 40% |
| Ducted, 2.5 to 3 tons | 4 · index 62% | 5 · index 45% |
| Ducted, 3.5 to 4.5 tons | 2 · index 63% | 3 · index 35% |
| Non-ducted, up to 1.5 tons | 8 · index 70% | 6 · index 34% |
| Non-ducted, 2 tons | 4 · index 70% | 2 · index 49% |
| Non-ducted, 2.5 to 3 tons | 4 · index 62% | 3 · index 69% |
| Non-ducted, 3.5 to 4.5 tons | 3 · index 44% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | SEA BREEZE+Cold-climate score, best model | TRUENORTHCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 75.2(50 is the typical model of its size class) (higher)HSZ9H424ZMOwith ducted air handler D9H424ZMI7 of 8 models qualify · AHRI 212595646 | 36.3(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models qualify · AHRI 218593150 |
| Ducted, 2 tons | 80.6(50 is the typical model of its size class) (higher)SZ24H424ZMOwith ducted air handler D24H424ZMI4 of 4 models qualify · AHRI 208128279 | 50.3(50 is the typical model of its size class)WLWHD(24)ND3MO4 of 4 models qualify · AHRI 218593151 |
| Ducted, 2.5 to 3 tons | 70.6(50 is the typical model of its size class) (higher)CSZ36H424ZMOwith ducted air handler AH36H424ZMI3 of 4 models qualify · AHRI 211126514 | 55.4(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD36AH2/A-D(U)4 of 4 models qualify · AHRI 218828997 |
| Ducted, 3.5 to 4.5 tons | 60.8(50 is the typical model of its size class) (higher)HMZ48H424ZMO1 of 2 models qualify · AHRI 208816899 | 58.2(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)1 of 3 models qualify · AHRI 218828999 |
| Non-ducted, up to 1.5 tons | 86.6(50 is the typical model of its size class) (higher)SZ9H424ZMOwith ductless indoor unit WM9H424ZMI7 of 8 models qualify · AHRI 208674954 | 74.0(50 is the typical model of its size class)WLWHD(18)ND3MO5 of 6 models qualify · AHRI 218593147 |
| Non-ducted, 2 tons | 87.1(50 is the typical model of its size class) (higher)HSZ24H424ZMOwith ductless indoor unit CA24H424ZMI4 of 4 models qualify · AHRI 212595654 | 77.3(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 218593148 |
| Non-ducted, 2.5 to 3 tons | 76.1(50 is the typical model of its size class) (higher)CSZ36H424ZMOwith ductless indoor unit CA36H424ZMI3 of 4 models qualify · AHRI 208128274 | 74.7(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models qualify · AHRI 218593146 |
| Non-ducted, 3.5 to 4.5 tons | 76.1(50 is the typical model of its size class)CSZ48H424ZMOwith ductless indoor unit CA48H424ZMI2 of 3 models qualify · AHRI 208128275 | No models in this size class |
All-around best
| Size and duct type | SEA BREEZE+All-around score, best model | TRUENORTHAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)HSZ9H424ZMOwith ducted air handler D9H424ZMI8 of 8 models have all five ratings · AHRI 212595646 | 31.8(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models have all five ratings · AHRI 218593150 |
| Ducted, 2 tons | 84.0(50 is the typical model of its size class) (higher)SZ24H424ZMOwith ducted air handler D24H424ZMI4 of 4 models have all five ratings · AHRI 208128279 | 60.8(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD24AH2/A-D(U)5 of 5 models have all five ratings · AHRI 218828996 |
| Ducted, 2.5 to 3 tons | 74.7(50 is the typical model of its size class) (higher)HMZ28H424ZMO4 of 4 models have all five ratings · AHRI 208128295 | 53.0(50 is the typical model of its size class)WLWHD(30)ND3MO3 of 3 models have all five ratings · AHRI 218593152 |
| Ducted, 3.5 to 4.5 tons | 63.5(50 is the typical model of its size class) (higher)MZ48H424ZMO2 of 2 models have all five ratings · AHRI 208128292 | 63.3(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)3 of 3 models have all five ratings · AHRI 218828999 |
| Non-ducted, up to 1.5 tons | 87.1(50 is the typical model of its size class) (higher)SZ9H424ZMOwith ductless indoor unit WM9H424ZMI8 of 8 models have all five ratings · AHRI 208674954 | 58.6(50 is the typical model of its size class)WLWHD(18)ND3MO6 of 6 models have all five ratings · AHRI 218593147 |
| Non-ducted, 2 tons | 78.4(50 is the typical model of its size class) (higher)HMZ24H424ZMO4 of 4 models have all five ratings · AHRI 208816895 | 72.2(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models have all five ratings · AHRI 218593148 |
| Non-ducted, 2.5 to 3 tons | 71.5(50 is the typical model of its size class) (higher)HMZ36H424ZMO4 of 4 models have all five ratings · AHRI 208128297 | 70.9(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models have all five ratings · AHRI 218593146 |
| Non-ducted, 3.5 to 4.5 tons | 48.3(50 is the typical model of its size class)MZ48H424ZMO3 of 3 models have all five ratings · AHRI 208128291 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | SEA BREEZE+ | TRUENORTH |
|---|---|---|
| COP at 5°F | beats 98% · 2.45SZ12H424ZMONon-ducted, up to 1.5 tons | beats 89% · 2.21WLWHD(18)ND3MONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 96% · 105%HMZ24H424ZMONon-ducted, 2 tons | beats 86% · 89%WLWHD(30)ND3MODucted, 2.5 to 3 tons |
| HSPF2 | beats 98% · 12.0HSZ9H424ZMODucted, up to 1.5 tons | beats 82% · 10.0WLWHD(36)ND3MONon-ducted, 2.5 to 3 tons |
| SEER2 | beats 98% · 21.3MZ27H424ZMODucted, 2 tons | beats 77% · 17.0WLUD60W/A-D(U)Ducted, 3.5 to 4.5 tons |
| EER2 | beats 95% · 15.8HSZ9H424ZMONon-ducted, up to 1.5 tons | beats 84% · 12.5WLWHD(30)ND3MONon-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 98% · 41,000 Btu/hCSZ36H424ZMONon-ducted, 2.5 to 3 tons | beats 85% · 13,800 Btu/hWLWHD(18)ND3MONon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- SEA BREEZE+ (median, middle 50%)
- TRUENORTH (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,710 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,710 | 55% | 58% | 66% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,710 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,710 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| SEA BREEZE+, 47°F | 18 | 100% | 100% | 100% | 100% | 100% |
| SEA BREEZE+, 17°F | 18 | 67% | 69% | 78% | 80% | 93% |
| SEA BREEZE+, 5°F | 18 | 58% | 63% | 72% | 82% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| SEA BREEZE+, 47°F | 18 | 2.82 | 2.91 | 3.12 | 3.41 | 3.57 |
| SEA BREEZE+, 17°F | 18 | 2.02 | 2.07 | 2.21 | 2.33 | 2.4 |
| SEA BREEZE+, 5°F | 18 | 1.79 | 1.81 | 1.92 | 2.08 | 2.38 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TRUENORTH, 47°F | 17 | 100% | 100% | 100% | 100% | 100% |
| TRUENORTH, 17°F | 17 | 67% | 73% | 84% | 88% | 91% |
| TRUENORTH, 5°F | 17 | 57% | 61% | 71% | 75% | 77% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TRUENORTH, 47°F | 17 | 2.94 | 2.99 | 3.17 | 3.27 | 3.32 |
| TRUENORTH, 17°F | 17 | 2 | 2.08 | 2.3 | 2.41 | 2.46 |
| TRUENORTH, 5°F | 17 | 1.77 | 1.8 | 1.8 | 1.84 | 2.14 |
Source: NEEP ccASHP list · as of