Skip to content

SEA BREEZE+ vs TRUENORTH heat pumps

Measured against models of the same size and duct type, SEA BREEZE+ scores higher on 6 of the 6 ratings. SEA BREEZE+ has 19 outdoor models, TRUENORTH has 19 outdoor models. SEA BREEZE+ and TRUENORTH have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
SEA BREEZE+ and TRUENORTH on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, SEA BREEZE+ scores higher on 6 of the 6 ratings.
  • SEA BREEZE+
  • TRUENORTH
  • Other ranked manufacturers
SEA BREE…TRUENORTH

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingSEA BREEZE+TRUENORTH
Efficiency index66% (higher)median —42% (higher)median —
COP at 5°F47% (higher)median 1.9037% (higher)median 1.80
Capacity retention at 5°F69% (higher)median 85%59% (higher)median 72%
HSPF278% (higher)median 10.647% (higher)median 8.5
SEER273% (higher)median 21.039% (higher)median 17.5
EER263% (higher)median 12.533% (higher)median 10.5
Heating capacity at 5°F67% (higher)median 20,000 Btu/h61% (higher)median 20,000 Btu/h
Outdoor models1919
AHRI certifications6971

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardSEA BREEZE+TRUENORTH
CEE 2025 Tier 1 (Split ASHP)89.5%17 models57.9%11 models
CEE 2026 Tier 1 (Split ASHP)84.2%16 models52.6%10 models
CEE Advanced Tier (Split ASHP)5.3%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)84.2%16 models68.4%13 models
DOE Cold Climate Heat Pump Challenge5.3%1 models0%0 models
ENERGY STAR Cold Climate89.5%17 models57.9%11 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • SEA BREEZE+
  • TRUENORTH
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeSEA BREEZE+TRUENORTH
Ducted, up to 1.5 tons8 · index 67%3 · index 29%
Ducted, 2 tons4 · index 78%3 · index 40%
Ducted, 2.5 to 3 tons4 · index 62%5 · index 45%
Ducted, 3.5 to 4.5 tons2 · index 63%3 · index 35%
Non-ducted, up to 1.5 tons8 · index 70%6 · index 34%
Non-ducted, 2 tons4 · index 70%2 · index 49%
Non-ducted, 2.5 to 3 tons4 · index 62%3 · index 69%
Non-ducted, 3.5 to 4.5 tons3 · index 44%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeSEA BREEZE+Cold-climate score, best modelTRUENORTHCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class) (higher)HSZ9H424ZMOwith ducted air handler D9H424ZMI7 of 8 models qualify · AHRI 21259564636.3(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models qualify · AHRI 218593150
Ducted, 2 tons80.6(50 is the typical model of its size class) (higher)SZ24H424ZMOwith ducted air handler D24H424ZMI4 of 4 models qualify · AHRI 20812827950.3(50 is the typical model of its size class)WLWHD(24)ND3MO4 of 4 models qualify · AHRI 218593151
Ducted, 2.5 to 3 tons70.6(50 is the typical model of its size class) (higher)CSZ36H424ZMOwith ducted air handler AH36H424ZMI3 of 4 models qualify · AHRI 21112651455.4(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD36AH2/A-D(U)4 of 4 models qualify · AHRI 218828997
Ducted, 3.5 to 4.5 tons60.8(50 is the typical model of its size class) (higher)HMZ48H424ZMO1 of 2 models qualify · AHRI 20881689958.2(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)1 of 3 models qualify · AHRI 218828999
Non-ducted, up to 1.5 tons86.6(50 is the typical model of its size class) (higher)SZ9H424ZMOwith ductless indoor unit WM9H424ZMI7 of 8 models qualify · AHRI 20867495474.0(50 is the typical model of its size class)WLWHD(18)ND3MO5 of 6 models qualify · AHRI 218593147
Non-ducted, 2 tons87.1(50 is the typical model of its size class) (higher)HSZ24H424ZMOwith ductless indoor unit CA24H424ZMI4 of 4 models qualify · AHRI 21259565477.3(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 218593148
Non-ducted, 2.5 to 3 tons76.1(50 is the typical model of its size class) (higher)CSZ36H424ZMOwith ductless indoor unit CA36H424ZMI3 of 4 models qualify · AHRI 20812827474.7(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models qualify · AHRI 218593146
Non-ducted, 3.5 to 4.5 tons76.1(50 is the typical model of its size class)CSZ48H424ZMOwith ductless indoor unit CA48H424ZMI2 of 3 models qualify · AHRI 208128275No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeSEA BREEZE+All-around score, best modelTRUENORTHAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)HSZ9H424ZMOwith ducted air handler D9H424ZMI8 of 8 models have all five ratings · AHRI 21259564631.8(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models have all five ratings · AHRI 218593150
Ducted, 2 tons84.0(50 is the typical model of its size class) (higher)SZ24H424ZMOwith ducted air handler D24H424ZMI4 of 4 models have all five ratings · AHRI 20812827960.8(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD24AH2/A-D(U)5 of 5 models have all five ratings · AHRI 218828996
Ducted, 2.5 to 3 tons74.7(50 is the typical model of its size class) (higher)HMZ28H424ZMO4 of 4 models have all five ratings · AHRI 20812829553.0(50 is the typical model of its size class)WLWHD(30)ND3MO3 of 3 models have all five ratings · AHRI 218593152
Ducted, 3.5 to 4.5 tons63.5(50 is the typical model of its size class) (higher)MZ48H424ZMO2 of 2 models have all five ratings · AHRI 20812829263.3(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)3 of 3 models have all five ratings · AHRI 218828999
Non-ducted, up to 1.5 tons87.1(50 is the typical model of its size class) (higher)SZ9H424ZMOwith ductless indoor unit WM9H424ZMI8 of 8 models have all five ratings · AHRI 20867495458.6(50 is the typical model of its size class)WLWHD(18)ND3MO6 of 6 models have all five ratings · AHRI 218593147
Non-ducted, 2 tons78.4(50 is the typical model of its size class) (higher)HMZ24H424ZMO4 of 4 models have all five ratings · AHRI 20881689572.2(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models have all five ratings · AHRI 218593148
Non-ducted, 2.5 to 3 tons71.5(50 is the typical model of its size class) (higher)HMZ36H424ZMO4 of 4 models have all five ratings · AHRI 20812829770.9(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models have all five ratings · AHRI 218593146
Non-ducted, 3.5 to 4.5 tons48.3(50 is the typical model of its size class)MZ48H424ZMO3 of 3 models have all five ratings · AHRI 208128291No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingSEA BREEZE+TRUENORTH
COP at 5°Fbeats 98% · 2.45SZ12H424ZMONon-ducted, up to 1.5 tonsbeats 89% · 2.21WLWHD(18)ND3MONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 96% · 105%HMZ24H424ZMONon-ducted, 2 tonsbeats 86% · 89%WLWHD(30)ND3MODucted, 2.5 to 3 tons
HSPF2beats 98% · 12.0HSZ9H424ZMODucted, up to 1.5 tonsbeats 82% · 10.0WLWHD(36)ND3MONon-ducted, 2.5 to 3 tons
SEER2beats 98% · 21.3MZ27H424ZMODucted, 2 tonsbeats 77% · 17.0WLUD60W/A-D(U)Ducted, 3.5 to 4.5 tons
EER2beats 95% · 15.8HSZ9H424ZMONon-ducted, up to 1.5 tonsbeats 84% · 12.5WLWHD(30)ND3MONon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 98% · 41,000 Btu/hCSZ36H424ZMONon-ducted, 2.5 to 3 tonsbeats 85% · 13,800 Btu/hWLWHD(18)ND3MONon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
SEA BREEZE+ vs TRUENORTH: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • SEA BREEZE+ (median, middle 50%)
  • TRUENORTH (median, middle 50%)
Heating capacity, % of its 47°F maximum72%71%COP at maximum capacity1.921.80

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
SEA BREEZE+: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
SEA BREEZE+, 47°F18100%100%100%100%100%
SEA BREEZE+, 17°F1867%69%78%80%93%
SEA BREEZE+, 5°F1858%63%72%82%85%
SEA BREEZE+: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
SEA BREEZE+, 47°F182.822.913.123.413.57
SEA BREEZE+, 17°F182.022.072.212.332.4
SEA BREEZE+, 5°F181.791.811.922.082.38
TRUENORTH: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F17100%100%100%100%100%
TRUENORTH, 17°F1767%73%84%88%91%
TRUENORTH, 5°F1757%61%71%75%77%
TRUENORTH: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TRUENORTH, 47°F172.942.993.173.273.32
TRUENORTH, 17°F1722.082.32.412.46
TRUENORTH, 5°F171.771.81.81.842.14

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter