Skip to content

Senville vs TEMP SHIFT heat pumps

Measured against models of the same size and duct type, TEMP SHIFT scores higher on 4 of the 6 ratings. Senville has 27 outdoor models, TEMP SHIFT has 28 outdoor models. TEMP SHIFT has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Senville and TEMP SHIFT on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, TEMP SHIFT scores higher on 4 of the 6 ratings.
  • Senville
  • TEMP SHIFT
  • Other ranked manufacturers
SenvilleTEMP SHI…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingSenvilleTEMP SHIFT
Efficiency index61% (higher)median — · 7th ranked59% (higher)median —
COP at 5°F46%median 1.91 · 22nd ranked47%median 1.91
Capacity retention at 5°F61%median 82% · 5th ranked74%median 84%
HSPF267%median 9.5 · 6th ranked74%median 9.6
SEER267% (higher)median 21.4 · 3rd ranked60% (higher)median 17.5
EER256% (higher)median 11.7 · 11th ranked47% (higher)median 10.6
Heating capacity at 5°F59%median 20,000 Btu/h · 6th ranked70%median 25,400 Btu/h
Outdoor models2728
AHRI certifications5966

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardSenvilleTEMP SHIFT
CEE 2025 Tier 1 (Split ASHP)70.4%19 models67.9%19 models
CEE 2026 Tier 1 (Split ASHP)63%17 models64.3%18 models
CEE Advanced Tier (Split ASHP)3.7%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)44.4%12 models67.9%19 models
DOE Cold Climate Heat Pump Challenge3.7%1 models0%0 models
ENERGY STAR Cold Climate51.9%14 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Senville
  • TEMP SHIFT
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeSenvilleTEMP SHIFT
Ducted, up to 1.5 tons5 · index 64%6 · index 57%
Ducted, 2 tons2 · index 73%3 · index 59%
Ducted, 2.5 to 3 tons5 · index 69%8 · index 57%
Ducted, 3.5 to 4.5 tons4 · index 63%6 · index 57%
Non-ducted, up to 1.5 tons10 · index 55%5 · index 70%
Non-ducted, 2 tons2 · index 51%1 · index 67%
Non-ducted, 2.5 to 3 tons9 · index 61%6 · index 59%
Non-ducted, 3.5 to 4.5 tons2 · index 67%3 · index 53%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeSenvilleCold-climate score, best modelTEMP SHIFTCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class)SENA/09HF/OQwith ducted air handler SENA/09HF/ID5 of 5 models qualify · AHRI 20764134575.2(50 is the typical model of its size class)TSMOX33009HFN1MY5Wwith ducted air handler TSMTIU09HWFN1M5 of 6 models qualify · AHRI 213479385
Ducted, 2 tons79.6(50 is the typical model of its size class)SENA/24HF/OQwith ducted air handler SENA/24HF/ID2 of 2 models qualify · AHRI 20764134879.6(50 is the typical model of its size class)TSMOD3024HFN1MU0Wwith ducted air handler TSMTIU24HWFN1M3 of 3 models qualify · AHRI 213479388
Ducted, 2.5 to 3 tons79.9(50 is the typical model of its size class)SENA-36HF-MOB3 of 5 models qualify · AHRI 21373265780.4(50 is the typical model of its size class) (higher)TSM3OK27HFN1M6 of 8 models qualify · AHRI 213479393
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)SENA-48HF-MOB3 of 4 models qualify · AHRI 21373266075.1(50 is the typical model of its size class)TSM5OG48HFN1M[X]4 of 6 models qualify · AHRI 213479399
Non-ducted, up to 1.5 tons78.3(50 is the typical model of its size class) (higher)SENA/09HF/OQwith ductless indoor unit SENA/09HF/IQ4 of 10 models qualify · AHRI 20757141875.9(50 is the typical model of its size class)TSMOX33009HFN1MY5Wwith ductless indoor unit TSMSAG11B09HRFN1MX7W(GA)5 of 5 models qualify · AHRI 216014856
Non-ducted, 2 tons87.1(50 is the typical model of its size class)SENA/24HF/OQwith ductless indoor unit SENA/24HF/ICQ1 of 2 models qualify · AHRI 20764134487.1(50 is the typical model of its size class)TSMOD3024HFN1MU0Wwith ductless indoor unit TSMCD124HRFN1MT0W(GA)1 of 1 models qualify · AHRI 213479382
Non-ducted, 2.5 to 3 tons91.3(50 is the typical model of its size class) (higher)SENA-36HF-MOB3 of 9 models qualify · AHRI 21373265687.5(50 is the typical model of its size class)TSM4OX63036HFN1M1X4 of 6 models qualify · AHRI 213479395
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class)SENA-48HF-MOB1 of 2 models qualify · AHRI 21373265980.7(50 is the typical model of its size class) (higher)TSM5OG48HFN1M[X]3 of 3 models qualify · AHRI 213479398

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeSenvilleAll-around score, best modelTEMP SHIFTAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class)SENA/09HF/OQwith ducted air handler SENA/09HF/ID5 of 5 models have all five ratings · AHRI 20764134585.4(50 is the typical model of its size class)TSMOX33009HFN1MY5Wwith ducted air handler TSMTIU09HWFN1M6 of 6 models have all five ratings · AHRI 213479385
Ducted, 2 tons80.2(50 is the typical model of its size class)SENA/24HF/OQwith ducted air handler SENA/24HF/ID2 of 2 models have all five ratings · AHRI 20764134880.2(50 is the typical model of its size class)TSMOD3024HFN1MU0Wwith ducted air handler TSMTIU24HWFN1M3 of 3 models have all five ratings · AHRI 213479388
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class)SENA-36HF-MOB5 of 5 models have all five ratings · AHRI 21373265783.7(50 is the typical model of its size class)TSM4OX63036HFN1M1X8 of 8 models have all five ratings · AHRI 213479396
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)SENA-48HF-MOB4 of 4 models have all five ratings · AHRI 21373266082.1(50 is the typical model of its size class)TSM5OG48HFN1M[X]5 of 5 models have all five ratings · AHRI 213479399
Ducted, 5 tons and upNo models in this size class42.0(50 is the typical model of its size class)TSMOE30U60HFN1MR0with ducted air handler TSMVC60HWFN1M1 of 1 models have all five ratings · AHRI 212925591
Non-ducted, up to 1.5 tons88.1(50 is the typical model of its size class) (higher)SENA/09HF/OQwith ductless indoor unit SENA/09HF/IQ10 of 10 models have all five ratings · AHRI 20757141885.0(50 is the typical model of its size class)TSMOX33009HFN1MY5Wwith ductless indoor unit TSMSAG11B09HRFN1MX7W(GA)5 of 5 models have all five ratings · AHRI 216014856
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)SENA/24HF/OQwith ductless indoor unit SENA/24HF/IQ2 of 2 models have all five ratings · AHRI 20765763071.9(50 is the typical model of its size class)TSMOD3024HFN1MU0Wwith ductless indoor unit TSMSAG11D23HRFN1MU0W1 of 1 models have all five ratings · AHRI 216014859
Non-ducted, 2.5 to 3 tons86.7(50 is the typical model of its size class) (higher)SENA-36HF-MOB7 of 9 models have all five ratings · AHRI 21373265677.3(50 is the typical model of its size class)TSM4OX63036HFN1M1X6 of 6 models have all five ratings · AHRI 213479395
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class) (higher)SENA-48HF-MOB2 of 2 models have all five ratings · AHRI 21373265973.9(50 is the typical model of its size class)TSM5OG48HFN1M[X]3 of 3 models have all five ratings · AHRI 213479398

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingSenvilleTEMP SHIFT
COP at 5°Fbeats 92% · 2.21SENA/24HF/OQNon-ducted, 2 tonsbeats 87% · 2.01TSMOD3136HFN1MP0WNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 97% · 103%SENA-36HF-MOBNon-ducted, 2.5 to 3 tonsbeats 97% · 101%TSM3OK27HFN1MDucted, 2.5 to 3 tons
HSPF2beats 98% · 12.0SENA/09HF/OQDucted, up to 1.5 tonsbeats 98% · 12.0TSMOX33009HFN1MY5WDucted, up to 1.5 tons
SEER2beats 99% · 20.9SENA-48HF-MOBDucted, 3.5 to 4.5 tonsbeats 99% · 20.9TSM5OG48HFN1M[X]Ducted, 3.5 to 4.5 tons
EER2beats 98% · 16.2SENA/09HF/OQNon-ducted, up to 1.5 tonsbeats 95% · 15.8TSMOX33009HFN1MY5WNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hSENA-18HF-MOBNon-ducted, up to 1.5 tonsbeats 98% · 41,000 Btu/hTSMOE30U36HFN1M(GA)Non-ducted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Senville vs TEMP SHIFT: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Senville (median, middle 50%)
  • TEMP SHIFT (median, middle 50%)
Heating capacity, % of its 47°F maximum70%71%COP at maximum capacity1.921.91

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
Senville: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Senville, 47°F21100%100%100%100%100%
Senville, 17°F2167%71%78%80%85%
Senville, 5°F2157%62%70%78%83%
Senville: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Senville, 47°F212.582.83.093.213.45
Senville, 17°F211.982.042.172.252.33
Senville, 5°F211.81.851.9222
TEMP SHIFT: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TEMP SHIFT, 47°F26100%100%100%100%100%
TEMP SHIFT, 17°F2666%74%77%82%87%
TEMP SHIFT, 5°F2657%63%71%80%83%
TEMP SHIFT: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TEMP SHIFT, 47°F262.792.883.063.173.35
TEMP SHIFT, 17°F261.942.062.192.282.35
TEMP SHIFT, 5°F261.811.841.911.982

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy