Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Star Air Kontrol vs YONAN heat pumps
Measured against models of the same size and duct type, YONAN scores higher on 3 of the 6 ratings. Star Air Kontrol has 55 outdoor models, YONAN has 55 outdoor models. Star Air Kontrol and YONAN have no QMID on file and are not ranked. They share hardware: 16 equipment families appear under both names.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Star Air Kontrol
- YONAN
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Star Air Kontrol | YONAN |
|---|---|---|
| Efficiency index | 51%median — | 55%median — |
| COP at 5°F | 56% (higher)median 1.99 | 54% (higher)median 2.00 |
| Capacity retention at 5°F | 35%median 66% | 36%median 66% |
| HSPF2 | 61%median 9.2 | 61%median 9.5 |
| SEER2 | 57%median 19.2 | 61%median 21.1 |
| EER2 | 41%median 10.6 | 51%median 12.2 |
| Heating capacity at 5°F | 44% (higher)median 17,700 Btu/h | 39% (higher)median 12,600 Btu/h |
| Outdoor models | 55 | 55 |
| AHRI certifications | 70 | 88 |
Share of models meeting each standard
| Standard | Star Air Kontrol | YONAN |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 50.9%28 models | 67.3%37 models |
| CEE 2026 Tier 1 (Split ASHP) | 43.6%24 models | 58.2%32 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 23.6%13 models | 34.5%19 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 20%11 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Star Air Kontrol
- YONAN
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Star Air Kontrol | YONAN |
|---|---|---|
| Ducted, up to 1.5 tons | 4 · index 58% | 5 · index 67% |
| Ducted, 2 tons | 3 · index 68% | 2 · index 79% |
| Ducted, 2.5–3 tons | 6 · index 53% | 5 · index 59% |
| Ducted, 3.5–4.5 tons | 7 · index 53% | 4 · index 56% |
| Ducted, 5 tons and up | 3 · index 51% | 1 · index 57% |
| Non-ducted, up to 1.5 tons | 18 · index 53% | 30 · index 56% |
| Non-ducted, 2 tons | 6 · index 51% | 8 · index 51% |
| Non-ducted, 2.5–3 tons | 7 · index 41% | 11 · index 47% |
| Non-ducted, 3.5–4.5 tons | 6 · index 41% | 6 · index 43% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Star Air KontrolCold-climate score, best model | YONANCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 67.8(50 is the typical model of its size class)SAK-12-DTMS/220Vwith ducted air handler SAK-12-DTMS/220V2 of 4 models qualify · AHRI 213081463 | 70.4(50 is the typical model of its size class) (higher)YOX-09HFN1with ducted air handler YTI-09HWFN14 of 5 models qualify · AHRI 208106973 |
| Ducted, 2 tons | 80.3(50 is the typical model of its size class)SAK-24-DTMS/220Vwith ducted air handler SAK-24-DTMS/220V2 of 3 models qualify · AHRI 211726522 | 80.3(50 is the typical model of its size class)YOD-24HFN1with ducted air handler YTI-24HWFN12 of 2 models qualify · AHRI 208106980 |
| Ducted, 2.5–3 tons | 57.4(50 is the typical model of its size class)SAK-27-22MUZ/220(OUT)*1 of 6 models qualify · AHRI 211726669 | 57.8(50 is the typical model of its size class) (higher)YSMO-30HRN12 of 5 models qualify · AHRI 207691834 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 7 models qualify) | None on this board (0 of 4 models qualify) |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 84.7(50 is the typical model of its size class)SAK-09-OC/220Vwith ductless indoor unit SAK-09-OC/220V4 of 18 models qualify · AHRI 213279897 | 86.0(50 is the typical model of its size class) (higher)YSA25-09HRN1with ductless indoor unit YSA25-09HRN1Also listed as YS-09HRFN1-C5OU9 of 30 models qualify · AHRI 207671408 |
| Non-ducted, 2 tons | 74.2(50 is the typical model of its size class)SAK-24CONS/220Vwith ductless indoor unit SAK-24CONS/220V3 of 6 models qualify · AHRI 213279887 | 74.2(50 is the typical model of its size class)YOD-24HFN1with ductless indoor unit YUE-24HRFN14 of 8 models qualify · AHRI 208106981 |
| Non-ducted, 2.5–3 tons | 49.3(50 is the typical model of its size class)SAK-27-22MUZ/220(OUT)*1 of 7 models qualify · AHRI 211726668 | 50.1(50 is the typical model of its size class) (higher)YSMO-30HRN12 of 11 models qualify · AHRI 207691833 |
| Non-ducted, 3.5–4.5 tons | 56.3(50 is the typical model of its size class)SAK-48CONS/220Vwith ductless indoor unit SAK-48CONS/220V1 of 6 models qualify · AHRI 213279889 | 56.3(50 is the typical model of its size class)YOE-48HFN1with ductless indoor unit YUE-48HRFN11 of 6 models qualify · AHRI 208106987 |
All-around best
| Size and duct type | Star Air KontrolAll-around score, best model | YONANAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 78.5(50 is the typical model of its size class)SAK-18-DTMS/220Vwith ducted air handler SAK-18-DTMS/220V4 of 4 models have all five ratings · AHRI 211726521 | 78.5(50 is the typical model of its size class)YOX-18HFN1with ducted air handler YTI-18HWFN15 of 5 models have all five ratings · AHRI 208106977 |
| Ducted, 2 tons | 83.8(50 is the typical model of its size class)SAK-24-DTMS/220Vwith ducted air handler SAK-24-DTMS/220V2 of 3 models have all five ratings · AHRI 211726522 | 83.8(50 is the typical model of its size class)YOD-24HFN1with ducted air handler YTI-24HWFN12 of 2 models have all five ratings · AHRI 208106980 |
| Ducted, 2.5–3 tons | 71.5(50 is the typical model of its size class)SAK-27-22MUZ/220(OUT)*4 of 6 models have all five ratings · AHRI 211726669 | 71.7(50 is the typical model of its size class) (higher)YSMO-30HRN15 of 5 models have all five ratings · AHRI 207691834 |
| Ducted, 3.5–4.5 tons | 63.5(50 is the typical model of its size class)SAK-48-21MUZ/220(OUT)*4 of 7 models have all five ratings · AHRI 211726673 | 63.5(50 is the typical model of its size class)YSMO-48HRN1Also listed as YSMO-48HFN14 of 4 models have all five ratings · AHRI 207691831 |
| Ducted, 5 tons and up | 57.1(50 is the typical model of its size class)SAK-60-DTMS/220V*with ducted air handler SAK-60-DTMS/220V3 of 3 models have all five ratings · AHRI 211726674 | 57.1(50 is the typical model of its size class)YOE-60HFN1with ducted air handler YHG-60HWFN11 of 1 models have all five ratings · AHRI 208106988 |
| Non-ducted, up to 1.5 tons | 77.2(50 is the typical model of its size class)SAK-09-OC/220Vwith ductless indoor unit SAK-09-OC/220V18 of 18 models have all five ratings · AHRI 213279897 | 88.4(50 is the typical model of its size class) (higher)YSA25-09HRN1with ductless indoor unit YSA25-09HRN1Also listed as YS-09HRFN1-C5OU30 of 30 models have all five ratings · AHRI 207671408 |
| Non-ducted, 2 tons | 72.0(50 is the typical model of its size class)SAK-24CONS/220Vwith ductless indoor unit SAK-24CONS/220V6 of 6 models have all five ratings · AHRI 213279887 | 77.5(50 is the typical model of its size class) (higher)YSA25-24HRN1with ductless indoor unit YSA25-24HRN1Also listed as YS-24HRFN1-C5OU8 of 8 models have all five ratings · AHRI 207671411 |
| Non-ducted, 2.5–3 tons | 66.7(50 is the typical model of its size class)SAK-27-22MUZ/220(OUT)*6 of 7 models have all five ratings · AHRI 211726668 | 67.1(50 is the typical model of its size class) (higher)YSMO-30HRN18 of 11 models have all five ratings · AHRI 207691833 |
| Non-ducted, 3.5–4.5 tons | 48.3(50 is the typical model of its size class)SAK-48-21MUZ/220(OUT)*6 of 6 models have all five ratings · AHRI 211726672 | 48.3(50 is the typical model of its size class)YSMO-48HRN1Also listed as YSMO-48HFN15 of 6 models have all five ratings · AHRI 207691830 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Star Air Kontrol | YONAN |
|---|---|---|
| COP at 5°F | beats 96% · 2.38SAK-18-24MS/220Non-ducted, up to 1.5 tons | beats 97% · 2.39YSA25-12HRN1Also listed as YS-12HRFN1-C5OUNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 73% · 59%SAK-60-DTMS/220VDucted, 5 tons and up | beats 96% · 114%YS-09HRFN1-E0OUNon-ducted, up to 1.5 tons |
| HSPF2 | beats 98% · 11.2SAK-24-DTMS/220VDucted, 2 tons | beats 98% · 11.2YOD-24HFN1Ducted, 2 tons |
| SEER2 | beats 98% · 21.0SAK-27-22MUZ/220(OUT)*Ducted, 2.5–3 tons | beats 99% · 28.5YS-09HRFN1-E0OUNon-ducted, up to 1.5 tons |
| EER2 | beats 85% · 12.5SAK-24-DTMS/220VDucted, 2 tons | beats 97% · 14.0YSA25-24HRN1Also listed as YS-24HRFN1-C5OUNon-ducted, 2 tons |
| Heating capacity at 5°F | beats 79% · 13,100 Btu/hSAK-18-OC/220VNon-ducted, up to 1.5 tons | beats 82% · 13,700 Btu/hYS-09HRFN1-E0OUNon-ducted, up to 1.5 tons |