- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
3 models
Sorted by manufacturer and model.
| # · Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|
| 1ACA-2502AAchazelwith ductless indoor unit ACA-2501A | 1 ton9,000 Btu/h · Non-ducted | 1.75 | 70% | 8.5 | 19.0 | 10.0 | 7,000 | CEE 25CEE 26Xcel | 1 | 214584770 |
| 2ACA-2504AAchazelwith ductless indoor unit ACA-2503A | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | 10.0 | 8,600 | CEE 25CEE 26Xcel | 1 | 214584771 |
| 3ACA-2508AAchazelwith ductless indoor unit ACA-2507A | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 59% | 8.5 | 19.0 | 9.4 | 11,600 | None | 1 | 214584772 |