Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

3 models

Sorted by manufacturer and model.
Page 1 of 1
# · Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1MAPLEHEAT-12EXTMAPLE HEATwith ductless indoor unit MAPLEHEAT-12INT1 ton12,000 Btu/h · Non-ducted1.9140%8.720.810.34,800None1214609257
2NE-T52-MHEAT3012EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3012I1 ton12,000 Btu/h · Non-ducted1.80100%10.425.514.012,000CEE 25CEE 26XcelES CC2215402352
3NE-T52-MHEAT3018EMAPLE HEAT · NE-T52 Serieswith ductless indoor unit NE-T52-MHEAT3018I1.5 tons18,000 Btu/h · Non-ducted1.80100%11.321.512.518,000CEE 25CEE 26XcelES CC2215402351

Download CSV of the matching modelsAll 3 matching models, every page, in this order.