- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
9,824 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 251H4H5S18*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith indoor coil EA*4X19L17A and furnace *80ESU0401712A | ACIQ | 1.5 tons18,300 Btu/h · Ducted | 2.02 | 47% | 7.5 | 15.2 | 12.5 | 7,900 | None | 114 | 213064873 |
| 252H4H5S24*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FMA4X30**AL | ACIQ | 2 tons25,000 Btu/h · Ducted | 2.24 | 48% | 8.1 | 15.2 | 12.5 | 11,400 | None | 77 | 213064867 |
| 253H4H5S30*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FM(C,U)4Z30**AL | ACIQ | 2.5 tons27,600 Btu/h · Ducted | 2.20 | 47% | 7.8 | 15.2 | 12.5 | 13,000 | None | 178 | 213080962 |
| 254H4H5S36*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*48L*C | ACIQ | 3 tons36,400 Btu/h · Ducted | 2.16 | 47% | 7.5 | 14.3 | 12.0 | 16,600 | None | 198 | 213069625 |
| 255H4H5S42*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*60L*D | ACIQ | 3.5 tons42,500 Btu/h · Ducted | 2.36 | 50% | 7.8 | 15.2 | 11.7 | 21,400 | None | 184 | 213081048 |
| 256H4H5S48*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*60L*D | ACIQ | 4 tons46,500 Btu/h · Ducted | 2.24 | 48% | 7.8 | 15.2 | 12.5 | 22,200 | None | 10 | 213069076 |
| 257H4H5S60*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*60L*D | ACIQ | 5 tons57,000 Btu/h · Ducted | 2.32 | 50% | 7.5 | 14.3 | 12.0 | 28,400 | None | 15 | 213069077 |
| 258H4H7T24*K*AAA*ACIQwith ducted air handler C(A,C,D,E)24B44+TDR | ACIQ | 2 tons21,600 Btu/h · Ducted | 2.61 | 53% | 7.5 | 14.3 | 11.3 | 13,000 | CEE 25 | 316 | 214604525 |
| 259H4H7T36*K*AAA*ACIQ · Mainline 17 SEER2 HPwith indoor coil EHD4X48AAL and furnace *80MSU0601716A | ACIQ | 3 tons34,200 Btu/h · Ducted | 2.24 | 50% | 7.5 | 15.2 | 11.7 | 17,500 | CEE 25CEE 26 | 417 | 213073772 |
| 260H4H7T48*K*AAA*ACIQwith ducted air handler C(A,C,D,E)48D34+TDR | ACIQ | 3.5 tons44,000 Btu/h · Ducted | 2.63 | 58% | 7.5 | 14.3 | 11.3 | 28,000 | CEE 25CEE 26 | 198 | 214604528 |
| 261H4H7T60*K*AAA*ACIQwith ducted air handler C(A,C,D,E)60B34+TDR | ACIQ | 4.5 tons52,000 Btu/h · Ducted | 2.64 | 61% | 7.5 | 14.3 | 11.3 | 35,600 | CEE 25CEE 26 | 100 | 214604529 |
| 262HVH824GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X37L21A*+WALLCON and furnace *80CTL0901716A | ACIQ | 2 tons24,400 Btu/h · Ducted | 2.00 | 57% | 8.1 | 17.0 | 10.5 | 12,400 | None | 290 | 213062694 |
| 263HVH825GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716A | ACIQ | 2 tons24,400 Btu/h · Ducted | 2.04 | 78% | 8.5 | 17.5 | 11.5 | 16,600 | CEE 25CEE 26Xcel | 156 | 213062589 |
| 264HVH825GKA2*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X43L21A and furnace OMV112K14A | ACIQ | 2 tons23,600 Btu/h · Ducted | 1.94 | 53% | 7.5 | 15.5 | 10.5 | 16,300 | None | 4 | 213067672 |
| 265HVH825GKA3*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716A | ACIQ | 2 tons24,400 Btu/h · Ducted | 2.04 | 78% | 8.5 | 17.5 | 11.5 | 16,600 | CEE 25CEE 26Xcel | 360 | 213062931 |
| 266HVH825GKA3*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X43L21A and furnace OMV112K14A | ACIQ | 2 tons23,400 Btu/h · Ducted | 1.94 | 53% | 7.5 | 15.0 | 10.5 | 16,300 | None | 4 | 213067111 |
| 267HVH836GKA3*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X43L21A*+WALLCON and furnace *80CTL0901716A | ACIQ | 3 tons34,000 Btu/h · Ducted | 1.98 | 58% | 8.1 | 16.5 | 9.5 | 19,100 | None | 234 | 213063152 |
| 268HVH837GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EN(A,D,W)4X42L21**+WALLCON and furnace *80CTL0902120A | ACIQ | 2.5 tons31,800 Btu/h · Ducted | 2.10 | 83% | 7.5 | 17.0 | 11.0 | 27,400 | CEE 25CEE 26Xcel | 223 | 213062483 |
| 269HVH837GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *95CSU1002122A | ACIQ | 3 tons33,200 Btu/h · Ducted | 2.02 | 131% | 8.5 | 18.0 | 11.5 | 24,800 | CEE 25CEE 26Xcel | 240 | 213067169 |
| 270HVH837GKA2*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X61L24A and furnace OMV154L20A | ACIQ | 3 tons33,000 Btu/h · Ducted | 2.12 | 60% | 8.1 | 17.0 | 11.7 | 25,800 | CEE 25CEE 26 | 74 | 213066907 |
| 271HVH848GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CTL1352422A | ACIQ | 4 tons45,500 Btu/h · Ducted | 2.08 | 64% | 8.5 | 16.5 | 10.0 | 30,000 | CEE 25 | 58 | 213062547 |
| 272HVH848GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CTL1352422A | ACIQ | 4 tons45,500 Btu/h · Ducted | 2.08 | 64% | 8.5 | 16.5 | 10.0 | 30,000 | CEE 25 | 58 | 213063446 |
| 273HVH848GKA2*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith ducted air handler FVM4X48***L | ACIQ | 4 tons46,000 Btu/h · Ducted | — | — | 7.7 | 16.0 | 10.5 | — | None | 1 | 213063418 |
| 274HVH860GKA**+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith ducted air handler FVM4X60***L | ACIQ | 4.5 tons56,500 Btu/h · Ducted | — | — | 8.0 | 14.5 | 9.5 | — | None | 1 | 213062313 |
| 275HVH860GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *80CTL0902120A | ACIQ | 4.5 tons56,000 Btu/h · Ducted | 1.84 | 58% | 8.1 | 16.5 | 9.5 | 35,200 | None | 60 | 213063479 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,824 models; narrow the filters for the rest.