Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,824 models

Sorted by manufacturer and model.
Page 11 of 393
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
251H4H5S18*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith indoor coil EA*4X19L17A and furnace *80ESU0401712AACIQ1.5 tons18,300 Btu/h · Ducted2.0247%7.515.212.57,900None114213064873
252H4H5S24*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FMA4X30**ALACIQ2 tons25,000 Btu/h · Ducted2.2448%8.115.212.511,400None77213064867
253H4H5S30*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FM(C,U)4Z30**ALACIQ2.5 tons27,600 Btu/h · Ducted2.2047%7.815.212.513,000None178213080962
254H4H5S36*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*48L*CACIQ3 tons36,400 Btu/h · Ducted2.1647%7.514.312.016,600None198213069625
255H4H5S42*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*60L*DACIQ3.5 tons42,500 Btu/h · Ducted2.3650%7.815.211.721,400None184213081048
256H4H5S48*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*60L*DACIQ4 tons46,500 Btu/h · Ducted2.2448%7.815.212.522,200None10213069076
257H4H5S60*K*AAA*ACIQ · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*60L*DACIQ5 tons57,000 Btu/h · Ducted2.3250%7.514.312.028,400None15213069077
258H4H7T24*K*AAA*ACIQwith ducted air handler C(A,C,D,E)24B44+TDRACIQ2 tons21,600 Btu/h · Ducted2.6153%7.514.311.313,000CEE 25316214604525
259H4H7T36*K*AAA*ACIQ · Mainline 17 SEER2 HPwith indoor coil EHD4X48AAL and furnace *80MSU0601716AACIQ3 tons34,200 Btu/h · Ducted2.2450%7.515.211.717,500CEE 25CEE 26417213073772
260H4H7T48*K*AAA*ACIQwith ducted air handler C(A,C,D,E)48D34+TDRACIQ3.5 tons44,000 Btu/h · Ducted2.6358%7.514.311.328,000CEE 25CEE 26198214604528
261H4H7T60*K*AAA*ACIQwith ducted air handler C(A,C,D,E)60B34+TDRACIQ4.5 tons52,000 Btu/h · Ducted2.6461%7.514.311.335,600CEE 25CEE 26100214604529
262HVH824GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X37L21A*+WALLCON and furnace *80CTL0901716AACIQ2 tons24,400 Btu/h · Ducted2.0057%8.117.010.512,400None290213062694
263HVH825GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716AACIQ2 tons24,400 Btu/h · Ducted2.0478%8.517.511.516,600CEE 25CEE 26Xcel156213062589
264HVH825GKA2*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X43L21A and furnace OMV112K14AACIQ2 tons23,600 Btu/h · Ducted1.9453%7.515.510.516,300None4213067672
265HVH825GKA3*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716AACIQ2 tons24,400 Btu/h · Ducted2.0478%8.517.511.516,600CEE 25CEE 26Xcel360213062931
266HVH825GKA3*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X43L21A and furnace OMV112K14AACIQ2 tons23,400 Btu/h · Ducted1.9453%7.515.010.516,300None4213067111
267HVH836GKA3*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X43L21A*+WALLCON and furnace *80CTL0901716AACIQ3 tons34,000 Btu/h · Ducted1.9858%8.116.59.519,100None234213063152
268HVH837GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EN(A,D,W)4X42L21**+WALLCON and furnace *80CTL0902120AACIQ2.5 tons31,800 Btu/h · Ducted2.1083%7.517.011.027,400CEE 25CEE 26Xcel223213062483
269HVH837GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *95CSU1002122AACIQ3 tons33,200 Btu/h · Ducted2.02131%8.518.011.524,800CEE 25CEE 26Xcel240213067169
270HVH837GKA2*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X61L24A and furnace OMV154L20AACIQ3 tons33,000 Btu/h · Ducted2.1260%8.117.011.725,800CEE 25CEE 2674213066907
271HVH848GKA**ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CTL1352422AACIQ4 tons45,500 Btu/h · Ducted2.0864%8.516.510.030,000CEE 2558213062547
272HVH848GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CTL1352422AACIQ4 tons45,500 Btu/h · Ducted2.0864%8.516.510.030,000CEE 2558213063446
273HVH848GKA2*+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith ducted air handler FVM4X48***LACIQ4 tons46,000 Btu/h · Ducted——7.716.010.5—None1213063418
274HVH860GKA**+TSTATACIQ · QUIETCOMFORT DELUXE 18 VS HP 2-STAGEwith ducted air handler FVM4X60***LACIQ4.5 tons56,500 Btu/h · Ducted——8.014.59.5—None1213062313
275HVH860GKA2*ACIQ · QUIETCOMFORT DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *80CTL0902120AACIQ4.5 tons56,000 Btu/h · Ducted1.8458%8.116.59.535,200None60213063479

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,824 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter