Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,824 models

Sorted by manufacturer and model.
Page 306 of 393
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
7626ACIQ-30Z-HP230BPolarWavewith ductless indoor unit ACIQ-30W-HP230BPolarWave2.5 tons30,000 Btu/h · Non-ducted1.8460%8.718.610.518,000CEE 251212316097
7627ACIQ-36-EHPBPolarWavewith ducted air handler ACIQ-36W-WMPolarWave3 tons35,000 Btu/h · Ducted1.9259%8.016.910.021,400None4213433285
7628ACIQ-36-HPPolarWavewith ducted air handler ACIQ-36-AHPolarWave3 tons36,000 Btu/h · Ducted1.7042%7.514.88.023,000None1212316056
7629ACIQ-36-HPBPolarWave · ACIQ serieswith ducted air handler ACIQ-36-ACLPolarWave3 tons35,000 Btu/h · Ducted2.0082%10.015.210.032,000CEE 25CEE 26XcelES CC4212394347
7630ACIQ-36-HPCPOLARWAVEwith ducted air handler ACIQ-36-AHBPolarWave3 tons36,000 Btu/h · Ducted1.9692%9.516.010.036,876CEE 25CEE 26XcelES CC4213492152
7631ACIQ-36Z-EZ230PolarWavewith ductless indoor unit ACIQ-36W-EZ230PolarWave3 tons34,400 Btu/h · Non-ducted——7.616.08.2—None1212316065
7632ACIQ-36Z-HH-M4BPolarWave · ACIQPolarWave3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9097%10.322.213.636,000CEE 25CEE 26XcelES CC3212316091
7633ACIQ-36Z-HP230PolarWavewith ductless indoor unit ACIQ-36W-HP230PolarWave3 tons36,000 Btu/h · Non-ducted——7.516.08.5—None1212316054
7634ACIQ-36Z-HP230BPolarWavewith ductless indoor unit ACIQ-36W-HP230BPolarWave3 tons36,000 Btu/h · Non-ducted1.8563%8.717.58.522,530None1212316070
7635ACIQ-36ZPL-HP230BPolarWave · ACIQwith ducted air handler ACIQ-36CD-HH-MBPolarWave3 tons36,000 Btu/h · Ducted and non-ducted1.9886%11.016.59.036,000XcelES CC3212316105
7636ACIQ-48-EHPBPolarWavewith ducted air handler ACIQ-48-AHBPolarWave4 tons47,000 Btu/h · Ducted1.9565%9.415.88.836,000None2213433279
7637ACIQ-48-HPBPolarWave · ACIQ serieswith ducted air handler ACIQ-48-ACLPolarWave4 tons46,000 Btu/h · Ducted1.8078%9.014.38.640,000None1212394348
7638ACIQ-48Z-HH-M5BPolarWave · ACIQPolarWave4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0092%9.821.811.745,000CEE 25CEE 26XcelES CC3212316094
7639ACIQ-48ZPL-HP230BPolarWave · ACIQwith ducted air handler ACIQ-48CD-HH-MBPolarWave4 tons48,000 Btu/h · Ducted and non-ducted2.0288%10.314.38.246,000ES CC3212316106
7640ACIQ-55Z-HH-M5BPolarWave · ACIQPolarWave4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7785%9.522.010.547,000CEE 25CEE 26XcelES CC3212316117
7641ACIQ-60-EHPBPolarWavewith ducted air handler ACIQ-60-ACLPolarWave4.5 tons53,000 Btu/h · Ducted1.9059%8.515.29.032,000None2212394343
7642ACIQ-60HPBPolarWave · ACIQ serieswith ducted air handler ACIQ-60-ACLPolarWave4.5 tons53,000 Btu/h · Ducted1.8085%8.614.58.646,500None1213433281
7643ACIQ-60ZPL-HP230BPolarWave · ACIQwith ducted air handler ACIQ-60CD-HH-MBPolarWave4.5 tons55,000 Btu/h · Ducted and non-ducted1.9793%9.515.89.453,000XcelES CC2212316107
7644ES-18Z-M2BPolarWave · ES SERIESPolarWave1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0066%10.522.913.912,600CEE 25CEE 26XcelES CC3212316120
7645ES-27Z-M3BPolarWave · ES SERIESPolarWave2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0068%9.524.612.719,000CEE 25CEE 263212316123
7646ES-36Z-M4BPolarWave · ES SERIESPolarWave3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8068%9.523.911.725,200CEE 25CEE 263212316126
7647ES-48Z-M5BPolarWave · ES SERIESPolarWave4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%8.723.412.533,000CEE 25CEE 263212316129
7648ES-55Z-M5BPolarWavePolarWave4.5 tons55,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8060%9.121.310.533,200CEE 253212316132
7649EZ-09Z-HP115PolarWave · EZ Serieswith ductless indoor unit EZ-09W-HP115PolarWave1 ton9,000 Btu/h · Non-ducted1.7564%9.420.011.56,400CEE 25CEE 261214810604
7650EZ-12Z-HP115PolarWavewith ductless indoor unit EZ-12W-HP115PolarWave1 ton12,000 Btu/h · Non-ducted2.1058%9.318.99.07,000None1214810580

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,824 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter