- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
9,695 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 7901RP15AZ24AJ2NRHEEMwith indoor coil D(A,C,E)36D24+TDR and furnace R801V1004A17UHN | Rheem | 2 tons22,200 Btu/h · Ducted | 3.15 | 71% | 8.5 | 16.3 | 11.8 | 16,400 | CEE 25CEE 26XcelES CC | 308 | 214802736 |
| 7902RP15AZ30AJ2NRUUDwith indoor coil CP31A34+TDR and furnace U802VA075317M | Rheem | 2.5 tons27,000 Btu/h · Ducted | 2.71 | 71% | 8.0 | 15.3 | 11.6 | 20,200 | CEE 25CEE 26XcelES CC | 454 | 214391790 |
| 7903RP15AZ36AJ2NRUUDwith indoor coil CP37A34+TDR and furnace R802V1005A21UHN | Rheem | 2.5 tons32,800 Btu/h · Ducted | 2.85 | 75% | 8.0 | 15.3 | 11.6 | 25,800 | XcelES CC | 276 | 214391832 |
| 7904RP15AZ42AJ2NRHEEMwith indoor coil D(A,C,E)60D34+TDR and furnace R801V0754A17DZ | Rheem | 3.5 tons39,000 Btu/h · Ducted | 3.11 | 74% | 7.7 | 14.6 | 9.0 | 29,200 | XcelES CC | 730 | 214802795 |
| 7905RP15AZ48AJ2NRUUDwith indoor coil CP61B34+TDR and furnace ROCB118V05M | Rheem | 3.5 tons44,500 Btu/h · Ducted | 3.18 | 78% | 7.6 | 14.6 | 9.0 | 35,600 | CEE 25CEE 26XcelES CC | 803 | 214392040 |
| 7906RP15AZ60AJ2NRUUDwith indoor coil CP61C34+TDR and furnace U802VA125524M | Rheem | 4.5 tons53,000 Btu/h · Ducted | 3.29 | 77% | 8.1 | 15.1 | 11.5 | 44,000 | CEE 25CEE 26ES CC | 295 | 214392097 |
| 7907RP16AZ24AJ3CRHEEMwith indoor coil RCFZ2517STANM and furnace R802VA050317M | Rheem | 2 tons22,400 Btu/h · Ducted | 2.10 | 52% | 8.1 | 16.0 | 10.0 | 11,700 | None | 35 | 210589310 |
| 7908RP16AZ36AJ3CRHEEMwith indoor coil RCFZ3717STANM and furnace R802VA075317M | Rheem | 3 tons34,200 Btu/h · Ducted | 2.10 | 56% | 8.1 | 16.0 | 10.0 | 19,000 | None | 46 | 210589313 |
| 7909RP16AZ48AJ3CRHEEMwith indoor coil RCFZ4821STANM and furnace R802VA100521M | Rheem | 4 tons45,000 Btu/h · Ducted | 2.30 | 56% | 8.1 | 17.0 | 10.0 | 25,400 | None | 31 | 213090003 |
| 7910RP16AZ60AJ3CRHEEMwith indoor coil C(A,C,D)60E44+TDR and furnace R962V0855A21M4S | Rheem | 4.5 tons51,000 Btu/h · Ducted | 2.67 | 73% | 8.0 | 15.0 | 9.9 | 39,500 | None | 31 | 213679824 |
| 7911RP1724HJVXARHEEMwith ductless indoor unit RICH24AXCJ | Rheem | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.04 | 97% | 10.1 | 20.8 | 12.8 | 23,200 | CEE 25CEE 26Xcel | 5 | 210839352 |
| 7912RP1730HJVXARHEEMwith ducted air handler RHMV3021SNAC | Rheem | 2.5 tons30,000 Btu/h · Ducted | 2.00 | 69% | — | — | — | 22,200 | None | 3 | 206137897 |
| 7913RP1736HJVXARHEEMwith ducted air handler RHMV3621MNAC | Rheem | 3 tons36,000 Btu/h · Ducted | 2.02 | 78% | — | — | — | 32,900 | CEE 25CEE 26Xcel | 3 | 206137898 |
| 7914RP1748HJVXARHEEMwith ducted air handler RHMV4821SNAC | Rheem | 4 tons45,500 Btu/h · Ducted | 2.09 | 65% | — | — | — | 34,200 | None | 3 | 206137899 |
| 7915RP18AZ24AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFZ2421HEAAM and furnace R802V1004A17UHS | Rheem | 2 tons22,800 Btu/h · Ducted | 2.10 | 108% | 8.5 | 20.0 | 12.5 | 26,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 28 | 212609307 |
| 7916RP18AZ36AJVCRHEEM · PRESTIGE SERIESwith indoor coil RCFZ6021SEAAM and furnace R802VA075317M | Rheem | 3 tons34,200 Btu/h · Ducted | 2.20 | 119% | 8.5 | 20.0 | 12.5 | 43,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 34 | 210589387 |
| 7917RP18AZ48AJVCRHEEM · PRESTIGE SERIESwith ducted air handler RHMVZ6021SEACA | Rheem | 4 tons45,000 Btu/h · Ducted | 2.00 | 88% | 8.5 | 19.0 | 12.0 | 42,000 | CEE 25CEE 26XcelES CC | 25 | 208552859 |
| 7918RP18AZ60AJVCRHEEMwith indoor coil RCFZ6021SEAAM and furnace R962V0705A21M4S | Rheem | 4.5 tons52,500 Btu/h · Ducted | 2.00 | 96% | 8.1 | 18.0 | 10.0 | 50,500 | Xcel | 15 | 209872733 |
| 7919SP1436AC1SUREwith ducted air handler SBHP-21 | Rheem | 3 tons34,200 Btu/h · Ducted | — | — | — | — | — | — | None | 4 | 9097397 |
| 7920SP1436FC1SUREwith ducted air handler SBHP-21 | Rheem | 3 tons34,200 Btu/h · Ducted | — | — | — | — | — | — | None | 6 | 10580443 |
| 7921SP1442CC1SUREwith ducted air handler SH1C4821STAN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | — | — | — | — | None | 7 | 204658452 |
| 7922SP1442CD1SUREwith ducted air handler SH1C4821STAN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | — | — | — | — | None | 7 | 204658453 |
| 7923SP1442GC1SUREwith ducted air handler SH1C4821STAN | Rheem | 3.5 tons40,000 Btu/h · Ducted | — | — | — | — | — | — | None | 16 | 205288034 |
| 7924SP1448AC1SUREwith ducted air handler SH1C4821STAN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | — | — | — | — | None | 2 | 9097477 |
| 7925SP1448AD1SUREwith ducted air handler SH1C4821STAN | Rheem | 4 tons45,500 Btu/h · Ducted | — | — | — | — | — | — | None | 2 | 9097489 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,695 models; narrow the filters for the rest.