Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,824 models

Sorted by manufacturer and model.
Page 329 of 393
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
8201AC048BXADCHSAMSUNG · 4-Way Cassette (WindFree™)with ductless indoor unit AC048BN4DCHSamsung4 tons48,000 Btu/h · Ducted and non-ducted1.9881%8.617.88.343,500None4207465436
8202AC048BXUPCHSAMSUNGwith ducted air handler L(E,G)M48D4Samsung4 tons47,500 Btu/h · Ducted2.35105%8.517.08.546,000CEE AdvDOEES CC6213350965
8203AC060BXUPCHSAMSUNGwith ducted air handler L(E,G)M60E4Samsung4.5 tons56,500 Btu/h · Ducted2.34102%9.017.58.554,000CEE AdvDOEES CC4213350966
8204AJ020BXJ2CHSAMSUNG · FJMSamsung1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7670%8.619.512.715,500CEE 25CEE 26Xcel3207349914
8205AJ020BXS3CHSAMSUNG · FJM Max HeatSamsung2 tons21,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95100%9.019.013.522,000CEE 25CEE 26Xcel3207349917
8206AJ020CXS3CHSAMSUNG · FJM Max HeatSamsung2 tons21,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95105%10.523.015.022,000CEE 25CEE 26Xcel3213353367
8207AJ024BXJ3CHSAMSUNG · FJMSamsung2 tons22,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7766%8.819.512.716,500CEE 25CEE 263207349915
8208AJ024BXS4CHSAMSUNG · FJM Max HeatSamsung2 tons25,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.020.013.025,000CEE 25CEE 26Xcel3207349918
8209AJ024CXS4CHSAMSUNG · FJM Max HeatSamsung2 tons25,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.85100%10.423.014.625,000CEE 25CEE 26Xcel3213353368
8210AJ030BXS4CHSAMSUNG · FJM Max HeatSamsung2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.80100%9.020.012.528,600CEE 25CEE 26Xcel3207349919
8211AJ030CXS4CHSAMSUNG · FJM Max HeatSamsung2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.81101%10.422.513.528,600CEE 25CEE 26Xcel3213353369
8212AJ036BXJ4CHSAMSUNG · FJMSamsung2.5 tons32,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8173%9.021.012.526,400CEE 25CEE 26Xcel3207349916
8213AJ036BXS4CHSAMSUNG · FJM Max HeatSamsung3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.04100%9.321.512.536,600CEE 25CEE 26Xcel3207349920
8214AJ036CXS4CHSAMSUNG · FJM Max HeatSamsung3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.04108%9.521.512.536,600CEE 25CEE 26Xcel3213353370
8215AJ048BXJ5CHSAMSUNG · FJMSamsung4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.7565%9.021.010.531,400CEE 253207349374
8216AM036NXMDCRSAMSUNG · DVM S EcoSamsung3 tons38,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0982%10.022.012.531,000CEE 25CEE 26Xcel3202098116
8217AM036TXMDCHSAMSUNG · DVM S EcoSamsung3 tons38,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0982%10.022.012.531,000CEE 25CEE 26Xcel3205142809
8218AM048NXMDCRSAMSUNG · DVM S EcoSamsung4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0079%10.020.511.538,000CEE 25CEE 26Xcel3202057118
8219AM048TXMDCHSAMSUNG · DVM S EcoSamsung4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%10.020.511.538,000CEE 25CEE 26Xcel3205142810
8220AM053NXMDCRSAMSUNG · DVM S EcoSamsung4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0081%10.020.011.543,000CEE 25CEE 26Xcel3202083810
8221AM053TXMDCHSAMSUNG · DVM S EcoSamsung4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0081%10.020.011.543,000CEE 25CEE 26Xcel3205230040
8222AM060MXMDCHSAMSUNG · DVM S EcoSamsung5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8978%9.819.011.247,000CEE 25CEE 26Xcel310147097
8223AM060NXMDCRSAMSUNG · DVM S EcoSamsung5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8978%9.819.011.247,000CEE 25CEE 26Xcel3202083996
8224AR09CSDABWKXSAMSUNG · WindFree™ 3.0 (RAC)with ductless indoor unit AR09CSDABWKNSamsung1 ton9,000 Btu/h · Non-ducted2.25133%10.524.515.512,000CEE 25CEE 26CEE AdvXcelDOE1210445757
8225AR09CSDACWKXSAMSUNG · Max Heat 3.0 (RAC)with ductless indoor unit AR09CSDABWKNSamsung1 ton9,000 Btu/h · Non-ducted2.3091%10.524.515.510,000CEE 25CEE 26Xcel1210445758

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,824 models; narrow the filters for the rest.