Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,824 models

Sorted by manufacturer and model.
Page 35 of 393
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
851BMAH4816CBLUERIDGE · BMAH serieswith ducted air handler BMAH4816IBlueRidge4 tons47,000 Btu/h · Ducted1.9092%9.415.68.246,000ES CC2208101246
852BMAH6016CBLUERIDGE · BMAH serieswith ducted air handler BMAH6016IBlueRidge4.5 tons55,000 Btu/h · Ducted1.9182%9.415.38.848,500ES CC2210025757
853BMAHM3618CBLUERIDGEwith ducted air handler BMAHM3618IBlueRidge3 tons36,000 Btu/h · Ducted2.0663%9.015.48.224,000None1215359197
854BMKH0938/OBLUERIDGE · Saphirewith ductless indoor unit BMKH0938/IBlueRidge1 ton9,000 Btu/h · Non-ducted1.91144%11.027.016.613,000CEE 25CEE 26XcelES CC1205968027
855BMKH1231/OBLUERIDGE · Saphirewith ductless indoor unit BMKH1231/IBlueRidge1 ton12,000 Btu/h · Non-ducted1.9198%8.524.014.012,000CEE 25CEE 26XcelES CC1205968028
856BMKH1824/OBLUERIDGE · Saphirewith ductless indoor unit BMKH1824/IBlueRidge1.5 tons18,000 Btu/h · Non-ducted1.80111%10.022.013.520,000CEE 25CEE 26XcelES CC1205968029
857BMKH18M23UHBLUERIDGE · Ultra Heat Multi zoneBlueRidge1.5 tons18,000 Btu/h · Non-ducted1.81104%10.020.012.021,800CEE 25CEE 26Xcel1206221553
858BMKH18MCBLUERIDGE · New Multi-zone ODUwith ductless indoor unit PUD24KCH24S-IBlueRidge1.5 tons17,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2176%10.021.012.013,600CEE 25CEE 26XcelES CC3210534145
859BMKH18P/OBLUERIDGEwith ductless indoor unit BMKH18MCCBlueRidge1.5 tons18,000 Btu/h · Non-ducted1.9381%8.519.010.114,500CEE 25CEE 26Xcel2215382942
860BMKH2422/OBLUERIDGE · Saphirewith ductless indoor unit BMKH2422/IBlueRidge2 tons22,000 Btu/h · Non-ducted1.90100%9.521.513.024,000CEE 25CEE 26XcelES CC1205968031
861BMKH24M23UHBLUERIDGE · Ultra Heat Multi zoneBlueRidge2 tons22,000 Btu/h · Non-ducted1.80115%10.020.012.030,000CEE 25CEE 26Xcel1206221554
862BMKH24MCBLUERIDGE · New Multi-zone ODUBlueRidge2 tons23,200 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1090%10.021.012.521,600CEE 25CEE 26XcelES CC3210534146
863BMKH30MCBLUERIDGE · New Multi-zone ODUBlueRidge2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8476%10.021.012.522,800CEE 25CEE 26XcelES CC3210534147
864BMKH36M23UHBLUERIDGE · Ultra Heat Multi zoneBlueRidge3 tons36,000 Btu/h · Non-ducted1.8278%8.616.09.028,200Xcel1206221555
865BMKH42M23UHBLUERIDGE · Ultra Heat Multi zoneBlueRidge3.5 tons42,000 Btu/h · Non-ducted1.8274%8.616.09.031,200XcelES CC1206221556
866BMKH42MCBLUERIDGE · New Multi-zone ODUBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9281%10.021.012.032,400CEE 25CEE 26XcelES CC3210534148
867BMM18CBLUERIDGE · BM seriesBlueRidge1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0066%10.221.012.512,600CEE 25CEE 26XcelES CC3207641279
868BMM18HHCBLUERIDGE · BM seriesBlueRidge1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.83100%9.020.512.520,000CEE 25CEE 26XcelES CC3207641291
869BMM27CBLUERIDGE · BM seriesBlueRidge2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8371%9.221.011.720,000CEE 25CEE 26Xcel3207641282
870BMM27HH2CBLUERIDGE · BMM seriesBlueRidge2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.92103%10.021.812.227,800CEE 25CEE 26XcelES CC3212360178
871BMM27HHCBLUERIDGE · BM seriesBlueRidge2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8089%9.520.011.725,000CEE 25CEE 26XcelES CC3207641294
872BMM36CBLUERIDGEBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8065%9.623.110.624,000CEE 253207641286
873BMM36HH2CBLUERIDGE · BMM seriesBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.95100%10.921.012.036,000CEE 25CEE 26XcelES CC3213363376
874BMM36HHCBLUERIDGE · BM seriesBlueRidge3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9097%9.720.012.536,000CEE 25CEE 26XcelES CC3207641297
875BMM48CBLUERIDGE · BM seriesBlueRidge4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8069%9.521.111.033,000CEE 25CEE 263207641288