Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,824 models

Sorted by manufacturer and model.
Page 46 of 393
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1126MOE30U-48HFN1-M-[X1]CanAir · MAC serieswith ducted air handler MAC-48HWFN1-MCanAir4 tons46,000 Btu/h · Ducted1.8078%9.014.38.640,000None1209550337
1127MOE30U-48HFN1-MR0CanAirwith ducted air handler MAC-48HWFN1-MCanAir4 tons48,000 Btu/h · Ducted1.8055%8.314.38.628,000None1209550331
1128MOE30U-60HFN1-MR0CanAirwith ducted air handler MAC-60HWDN1-MN0CanAir4.5 tons53,000 Btu/h · Ducted1.9059%8.515.29.032,000None1209550332
1129MOE31U-36HFN1-MCanAir · MAC serieswith ducted air handler MAC-36HWFN1-MCanAir3 tons35,000 Btu/h · Ducted2.0082%10.015.210.032,000XcelES CC1209550336
1130MOX330-18HFN1-MR0CanAirwith ducted air handler MAC-24HWDN1-MN0CanAir1.5 tons18,000 Btu/h · Ducted1.9456%8.615.210.210,400None1209550327
1131MOX430-24HFN1-MR0CanAir · MAC serieswith ducted air handler MAC-24HWDN1-MN0CanAir2 tons24,000 Btu/h · Ducted2.2072%9.815.710.018,500XcelES CC1209550328
1132MOX430U-18HFN1-MCanAir · MAC serieswith ducted air handler MAC-24HWDN1-MN0CanAir1.5 tons18,000 Btu/h · Ducted2.2079%9.516.111.715,000CEE 25CEE 26XcelES CC1209550333
1133(C,H,T)4H5S18*K*AAA*KENMORE · MAINLINE 15 SEER2 HPwith indoor coil EA*4X19L17A and furnace *80ESU0401712ACarrier1.5 tons18,300 Btu/h · Ducted2.0247%7.515.212.57,900None390211044548
1134(C,H,T)4H5S24*K*AAA*KENMORE · MAINLINE 15 SEER2 HPwith indoor coil EA*4X37L21A and furnace *80MSU0601716ACarrier2 tons24,800 Btu/h · Ducted2.1851%7.516.012.011,200None255214336965
1135(C,H,T)4H5S30*K*AAA*KENMORE · MAINLINE 15 SEER2 HPwith ducted air handler FM(C,U)4Z30**ALCarrier2.5 tons27,600 Btu/h · Ducted2.2047%7.815.212.513,000None323211044672
1136(C,H,T)4H5S36*K*AAA*KENMORE · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*48L*CCarrier3 tons36,400 Btu/h · Ducted2.1647%7.514.312.016,600None630211231020
1137(C,H,T)4H5S42*K*AAA*KENMORE · MAINLINE 15 SEER2 HPwith ducted air handler FJMA4*60L*DCarrier3.5 tons42,500 Btu/h · Ducted2.3650%7.815.211.721,400None365211581454
1138(C,H,T)4H5S48*K*AAA*KENMORE · MAINLINE 15 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCONCarrier4 tons47,000 Btu/h · Ducted2.2647%7.515.212.022,000None43213301779
1139(C,H,T)4H5S60*K*AAA*KENMORE · MAINLINE 15 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCONCarrier5 tons57,500 Btu/h · Ducted2.3450%8.115.012.528,200None26213301787
1140(C,H,T)4H7T24*K*AAA*KENMORE · Mainline 17 SEER2 HPwith indoor coil EA*4X37L21A and furnace *95MSU1002122ACarrier2 tons23,600 Btu/h · Ducted2.4045%8.117.012.511,000CEE 251,045212321116
1141(C,H,T)4H7T36*K*AAA*KENMORE · Mainline 17 SEER2 HPwith ducted air handler FCMB4B48L0C*+WALLCONCarrier3 tons34,400 Btu/h · Ducted2.2651%8.116.012.017,800CEE 25CEE 261,057213301819
1142(C,H,T)4H7T48*K*AAA*KENMORE · Mainline 17 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCONCarrier4 tons47,500 Btu/h · Ducted2.4251%8.117.512.524,000CEE 25CEE 26562213301835
1143(C,H,T)4H7T60*K*AAA*KENMORE · Mainline 17 SEER2 HPwith ducted air handler FCMB4B60L0D*+WALLCONCarrier5 tons57,000 Btu/h · Ducted2.3852%8.016.512.530,000CEE 25CEE 26368213301843
1144(C,H,T)VH824GKA**KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X37L21A*+WALLCON and furnace *80CTL0901716ACarrier2 tons24,400 Btu/h · Ducted2.0057%8.117.010.512,400None598205750493
1145(C,H,T)VH824GKA**+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith ducted air handler FTMA4X24L0BCarrier2 tons23,400 Btu/h · Ducted——7.515.010.0—None2213280718
1146(C,H,T)VH825GKA2*KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X25L17A*+WALLCON and furnace *80CTL0901716ACarrier2 tons24,400 Btu/h · Ducted2.0478%8.517.511.516,600CEE 25CEE 26Xcel476204456506
1147(C,H,T)VH825GKA2*+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X43L21A and furnace OMV112K14ACarrier2 tons23,600 Btu/h · Ducted1.9453%7.515.510.516,300None8210595777
1148(C,H,T)VH825GKA3*KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X43L21A*+WALLCON and furnace *95CSU0802120ACarrier2 tons24,400 Btu/h · Ducted2.2486%8.517.011.018,200CEE 25CEE 26Xcel759210473103
1149(C,H,T)VH825GKA3*+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X37L21A and furnace *96VTN1002122BCarrier2 tons24,400 Btu/h · Ducted2.0053%7.515.511.016,300None87214377452
1150(C,H,T)VH836GKA3*KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X43L21A*+WALLCON and furnace *80CTL0901716ACarrier3 tons34,000 Btu/h · Ducted1.9858%8.116.59.519,100None593206998018

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,824 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter