Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

Simple view, for homeowners: top picks by size and what each rating measures →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,824 models

Sorted by manufacturer and model.
Page 47 of 393
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1151(C,H,T)VH837GKA**KENMORE · DELUXE 18 VS HPwith indoor coil EN(A,D,W)4X42L21**+WALLCON and furnace *80CTL0902120ACarrier2.5 tons31,800 Btu/h · Ducted2.1083%7.517.011.027,400CEE 25CEE 26Xcel581204299603
1152(C,H,T)VH837GKA**+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X37L21A and furnace *80VSL0902120BCarrier3 tons33,000 Btu/h · Ducted2.0052%8.515.511.025,000CEE 25CEE 26606214378793
1153(C,H,T)VH837GKA2*KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *95CSU1002122ACarrier3 tons33,200 Btu/h · Ducted2.2486%8.518.011.527,400CEE 25CEE 26Xcel598210470537
1154(C,H,T)VH837GKA2*+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X61L24A and furnace OMV154L20ACarrier3 tons33,000 Btu/h · Ducted2.1260%8.117.011.725,800CEE 25CEE 26645210462022
1155(C,H,T)VH848GKA**KENMORE · DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CTL1352422ACarrier4 tons45,500 Btu/h · Ducted2.0864%8.516.510.030,000CEE 25180204301461
1156(C,H,T)VH848GKA**+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X48L21A and furnace *80VSL0902120BCarrier4 tons45,000 Btu/h · Ducted1.8047%7.514.59.525,600None23214377462
1157(C,H,T)VH848GKA2*KENMORE · DELUXE 18 VS HPwith indoor coil EHD4X48AAL+WALLCON and furnace *80CSU0802120ACarrier4 tons45,500 Btu/h · Ducted2.3271%8.517.010.033,200CEE 25CEE 26Xcel200206997601
1158(C,H,T)VH848GKA2*+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith ducted air handler FVM4X48***LCarrier4 tons46,000 Btu/h · Ducted——7.716.010.5—None3206997439
1159(C,H,T)VH860GKA**+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith ducted air handler FVM4X60***LCarrier4.5 tons56,500 Btu/h · Ducted——8.014.59.5—None210464084
1160(C,H,T)VH860GKA2*KENMORE · DELUXE 18 VS HPwith indoor coil EA*4X61L24A*+WALLCON and furnace *80CTL0902120ACarrier4.5 tons56,000 Btu/h · Ducted1.8458%8.116.59.535,200None125206997448
1161(C,H,T)VH860GKA2*+TSTATKENMORE · DELUXE 18 VS HP 2-STAGEwith indoor coil EA*4X60L24A and furnace *96VTN1002122BCarrier4.5 tons53,500 Btu/h · Ducted1.8452%7.514.59.034,000None10214377687
1162214DEA036P0**B*BRYANT HEATING AND COOLING SYSTEMS · LEGACY LINE HPwith indoor coil CAP**3721AL and furnace 82*SB48070V17Carrier3 tons33,400 Btu/h · Ducted——————None67213923029
1163214DEA048P0**A*BRYANT HEATING AND COOLING SYSTEMS · LEGACY LINE HPwith indoor coil CAP**6121AL and furnace 82*TB66110V21Carrier4 tons47,500 Btu/h · Ducted——————None18213923708
1164214DEA060P0**A*BRYANT HEATING AND COOLING SYSTEMS · LEGACY LINE HPwith ducted air handler FT4BNBD60LCarrier5 tons57,500 Btu/h · Ducted——————None5214254083
1165214DPA036P0**B*BRYANT HEATING AND COOLING SYSTEMS · LEGACY LINE HPwith indoor coil CAP**3721AL and furnace 82*SB48070V17Carrier3 tons33,400 Btu/h · Ducted——————None67213923019
1166214DPA048P0**A*BRYANT HEATING AND COOLING SYSTEMS · LEGACY LINE HPwith indoor coil CAP**6121AL and furnace 82*TB66110V21Carrier4 tons47,500 Btu/h · Ducted——————None18213923695
1167214DPA060P0**A*BRYANT HEATING AND COOLING SYSTEMS · LEGACY LINE HPwith ducted air handler FT4BNBD60LCarrier5 tons57,500 Btu/h · Ducted——————None5214254052
1168215SAN018**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler A(E,F)M364+TDRCarrier1.5 tons18,000 Btu/h · Ducted2.4651%7.914.612.09,000None482215961000
1169215SAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*S+CM36B34+TDRCarrier2 tons23,400 Btu/h · Ducted2.5956%7.815.512.713,400None560215348744
1170215SAN030**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE(D,N,U)+DM36E34+TDRCarrier2 tons26,600 Btu/h · Ducted2.5956%7.514.411.915,900None314213195031
1171215SAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler L(E,G)M36B4Carrier3 tons33,400 Btu/h · Ducted2.5054%7.614.612.018,600None634214285952
1172215SAN042**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler L(E,G)M48A4Carrier3.5 tons40,000 Btu/h · Ducted2.7158%7.714.612.324,600None482214285953
1173215SAN048**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler L(E,G)M48D4Carrier4 tons45,000 Btu/h · Ducted2.7159%7.714.612.027,600None152214285954
1174215SAN060**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler L(E,G)M60A4Carrier4.5 tons55,500 Btu/h · Ducted2.8060%7.614.612.034,000None90214285955
1175224AES036*0**A*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED SERIES COMPACT HPwith indoor coil CAP**3721AL and furnace 82*SB48070V17Carrier2.5 tons32,800 Btu/h · Ducted——————None61213923323

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,824 models; narrow the filters for the rest.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter