Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

9,695 models

Sorted by manufacturer and model.
Page 48 of 388
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
1176225SAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE(D,N,U)+DM36E34+TDRCarrier2.5 tons32,400 Btu/h · Ducted2.4455%7.514.411.918,700None647213195039
1177225SAN042**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE(D,N,U)+DM59A44+TDRCarrier3.5 tons39,000 Btu/h · Ducted2.6958%7.714.612.124,600None472213195040
1178225SAN048**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE(D,N,U)+DM59A44+TDRCarrier3.5 tons43,500 Btu/h · Ducted2.6459%7.514.411.927,400None152213195041
1179225SAN060**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE(D,N,U)+DM59A44+TDRCarrier4.5 tons53,000 Btu/h · Ducted2.7260%7.514.311.734,000None83213195042
1180226ANA036*0**B*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED SERIES HP 2-STAGEwith ducted air handler FT4BN(B,X)C48LCarrier3 tons35,400 Btu/h · Ducted2.1248%7.516.012.017,000None13214826300
1181226CPA036*0**A*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED SERIES HPwith ducted air handler FT4BN(B,X)C36LCarrier3 tons33,000 Btu/h · Ducted——————None32214279123
1182226CPA048*0**A*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED SERIES HPwith ducted air handler FT4BN(B,X)C48LCarrier4 tons47,000 Btu/h · Ducted——————None9214279136
1183226CPA060*0**A*BRYANT HEATING AND COOLING SYSTEMS · PREFERRED SERIES HPwith indoor coil CSPH*6012AL and furnace 83*SB36040M17Carrier4.5 tons54,000 Btu/h · Ducted——————None20214115910
1184227TAN024**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*S+CM24A34+TDRCarrier2 tons21,400 Btu/h · Ducted2.7054%7.815.211.212,700CEE 25CEE 261,235215399888
1185227TAN036**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*S+CM48A34+TDRCarrier3 tons33,000 Btu/h · Ducted2.6657%7.815.212.020,000CEE 25CEE 261,142215399892
1186227TAN048**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE(D,N,U)+DM59A44+TDRCarrier3.5 tons43,000 Btu/h · Ducted2.8158%8.015.811.727,200CEE 25CEE 26784213195044
1187227TAN060**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler AE*L+CM59A44+TDRCarrier4.5 tons51,500 Btu/h · Ducted2.8360%7.815.211.734,600CEE 25CEE 26467215399904
1188227TBN024**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 17 SEER HPwith indoor coil CAP**3721AL and furnace 935SB66100M21Carrier2 tons23,600 Btu/h · Ducted2.4045%8.117.012.511,000CEE 251,322213384536
1189227TBN036**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 17 SEER HPwith ducted air handler FT4BNBD60LCarrier3 tons36,000 Btu/h · Ducted2.3450%8.117.012.517,700CEE 25CEE 261,409213925448
1190227TBN048**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 17 SEER HPwith ducted air handler F54AA*C48LCarrier4 tons46,500 Btu/h · Ducted2.3451%8.116.012.524,000CEE 25CEE 26822213386203
1191227TBN060**AA*BRYANT HEATING AND COOLING SYSTEMS · 2-STAGE 17 SEER HPwith ducted air handler F54AA*D60LCarrier5 tons57,000 Btu/h · Ducted2.3451%8.116.012.030,800CEE 25CEE 26472213386205
119225HCB636A*031*CARRIERwith indoor coil C36A***L539 and furnace 58TP*A070V17**16Carrier3 tons34,600 Btu/h · Ducted——7.815.212.0—None40212367091
119325SCA518A**30*CARRIERwith indoor coil D(A,C,E)24B44+TDR and furnace 58TP*B045V14**12Carrier1.5 tons17,200 Btu/h · Ducted2.7064%7.514.811.710,500None886213754183
119425SCA524A**30*CARRIERwith indoor coil D(A,C,E)30C44+TDR and furnace 59TP6C100V21**22Carrier2 tons23,800 Btu/h · Ducted3.0475%7.615.511.916,100Xcel1,175213754846
119525SCA530A**30*CARRIERwith indoor coil D(A,C,E)36C34+TDR and furnace 58TP*A045V14**12Carrier2 tons26,600 Btu/h · Ducted2.8155%7.614.512.015,500None1,193213201402
119625SCA536A**30*CARRIERwith indoor coil D(A,C,E)36C34+TDR and furnace 59TN6B100C21**22Carrier3 tons33,200 Btu/h · Ducted2.7740%7.815.111.813,700Xcel1,568213202227
119725SCA542A**30*CARRIERwith indoor coil D(A,C,E)42B34+TDR and furnace 58S(B,C)*A090E24**20Carrier3 tons38,000 Btu/h · Ducted2.9030%7.714.411.912,800None1,140213202314
119825SCA548A**30*CARRIERwith indoor coil D(A,C,E)48D44+TDR and furnace 58S(B,C)*A110E24**20Carrier4 tons45,000 Btu/h · Ducted2.7729%7.614.511.513,800None186213202425
119925SCA560A**30*CARRIERwith ducted air handler AE*L+DM60B44+TDRCarrier4.5 tons53,000 Btu/h · Ducted2.7661%7.514.311.734,000None130215399579
120025SPA518A**30*CARRIERwith indoor coil D(A,C,E)24B44+TDR and furnace 58S(B,C)*A070E17**12Carrier1.5 tons16,500 Btu/h · Ducted2.9078%7.515.012.212,800None863213202433

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 9,695 models; narrow the filters for the rest.